ABAP Select data from SAP table /SCMB/ALPRM7029 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMB/ALPRM7029 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMB/ALPRM7029. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMB/ALPRM7029 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMB/ALPRM7029 TYPE STANDARD TABLE OF /SCMB/ALPRM7029,
      WA_/SCMB/ALPRM7029 TYPE /SCMB/ALPRM7029,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMB/ALPRM7029> TYPE /SCMB/ALPRM7029.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMB/ALPRM7029.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMB/ALPRM7029
  INTO TABLE IT_/SCMB/ALPRM7029.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMB/ALPRM7029
*  INTO TABLE @DATA(IT_/SCMB/ALPRM70292).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMB/ALPRM7029 INDEX 1 INTO DATA(WA_/SCMB/ALPRM70292).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMB/ALPRM7029 ASSIGNING </SCMB/ALPRM7029>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMB/ALPRM7029>-MANDT = 1.
</SCMB/ALPRM7029>-AID = 1.
</SCMB/ALPRM7029>-PARTNER_FROM = 1.
</SCMB/ALPRM7029>-PARTNER_TO = 1.
</SCMB/ALPRM7029>-ORDERID = 1.
ENDLOOP.

LOOP AT IT_/SCMB/ALPRM7029 INTO WA_/SCMB/ALPRM7029.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMB/ALPRM7029-ITEMID, sy-vline,
WA_/SCMB/ALPRM7029-CALLUPID, sy-vline,
WA_/SCMB/ALPRM7029-CALLUPDATETIME, sy-vline,
WA_/SCMB/ALPRM7029-CALLUPDTTME_ZN, sy-vline,
WA_/SCMB/ALPRM7029-ALDUEQTY, sy-vline,
WA_/SCMB/ALPRM7029-ALDUEUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMB/ALPRM7029 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMB/ALPRM7029 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMB/ALPRM7029 INTO WA_/SCMB/ALPRM7029. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit RELCV, internal->external for field ORDERID CALL FUNCTION 'CONVERSION_EXIT_RELCV_OUTPUT' EXPORTING input = WA_/SCMB/ALPRM7029-ORDERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/ALPRM7029-ORDERID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RELCV, internal->external for field CALLUPID CALL FUNCTION 'CONVERSION_EXIT_RELCV_OUTPUT' EXPORTING input = WA_/SCMB/ALPRM7029-CALLUPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/ALPRM7029-CALLUPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CALLUPDATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCMB/ALPRM7029-CALLUPDATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/ALPRM7029-CALLUPDATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALDUEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMB/ALPRM7029-ALDUEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/ALPRM7029-ALDUEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMB/ALPRM7029_STR,
MANDT TYPE STRING,
AID TYPE STRING,
PARTNER_FROM TYPE STRING,
PARTNER_TO TYPE STRING,
ORDERID TYPE STRING,
ITEMID TYPE STRING,
CALLUPID TYPE STRING,
CALLUPDATETIME TYPE STRING,
CALLUPDTTME_ZN TYPE STRING,
ALDUEQTY TYPE STRING,
ALDUEUNIT TYPE STRING,
ALDUETST TYPE STRING,
ALDUETZONE TYPE STRING,
RELEASE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMB/ALPRM7029_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMB/ALPRM7029_STR-MANDT sy-vline
WA_/SCMB/ALPRM7029_STR-AID sy-vline
WA_/SCMB/ALPRM7029_STR-PARTNER_FROM sy-vline
WA_/SCMB/ALPRM7029_STR-PARTNER_TO sy-vline
WA_/SCMB/ALPRM7029_STR-ORDERID sy-vline
WA_/SCMB/ALPRM7029_STR-ITEMID sy-vline
WA_/SCMB/ALPRM7029_STR-CALLUPID sy-vline
WA_/SCMB/ALPRM7029_STR-CALLUPDATETIME sy-vline
WA_/SCMB/ALPRM7029_STR-CALLUPDTTME_ZN sy-vline
WA_/SCMB/ALPRM7029_STR-ALDUEQTY sy-vline
WA_/SCMB/ALPRM7029_STR-ALDUEUNIT sy-vline
WA_/SCMB/ALPRM7029_STR-ALDUETST sy-vline
WA_/SCMB/ALPRM7029_STR-ALDUETZONE sy-vline
WA_/SCMB/ALPRM7029_STR-RELEASE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.