ABAP Select data from SAP table /SCDL/DL_DLVH_UPD_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCDL/DL_DLVH_UPD_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCDL/DL_DLVH_UPD_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCDL/DL_DLVH_UPD_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCDL/DL_DLVH_UPD_STR TYPE STANDARD TABLE OF /SCDL/DL_DLVH_UPD_STR,
      WA_/SCDL/DL_DLVH_UPD_STR TYPE /SCDL/DL_DLVH_UPD_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCDL/DL_DLVH_UPD_STR> TYPE /SCDL/DL_DLVH_UPD_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCDL/DL_DLVH_UPD_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCDL/DL_DLVH_UPD_STR
  INTO TABLE IT_/SCDL/DL_DLVH_UPD_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCDL/DL_DLVH_UPD_STR
*  INTO TABLE @DATA(IT_/SCDL/DL_DLVH_UPD_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCDL/DL_DLVH_UPD_STR INDEX 1 INTO DATA(WA_/SCDL/DL_DLVH_UPD_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCDL/DL_DLVH_UPD_STR ASSIGNING </SCDL/DL_DLVH_UPD_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCDL/DL_DLVH_UPD_STR>-MANDT = 1.
</SCDL/DL_DLVH_UPD_STR>-DOCID = 1.
</SCDL/DL_DLVH_UPD_STR>-DOCCAT = 1.
</SCDL/DL_DLVH_UPD_STR>-DOCTYPE = 1.
</SCDL/DL_DLVH_UPD_STR>-DOCNO = 1.
ENDLOOP.

LOOP AT IT_/SCDL/DL_DLVH_UPD_STR INTO WA_/SCDL/DL_DLVH_UPD_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCDL/DL_DLVH_UPD_STR-CRETST, sy-vline,
WA_/SCDL/DL_DLVH_UPD_STR-CREUSR, sy-vline,
WA_/SCDL/DL_DLVH_UPD_STR-CHGTST, sy-vline,
WA_/SCDL/DL_DLVH_UPD_STR-CHGUSR, sy-vline,
WA_/SCDL/DL_DLVH_UPD_STR-CHGVERSION, sy-vline,
WA_/SCDL/DL_DLVH_UPD_STR-MANUAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCDL/DL_DLVH_UPD_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCDL/DL_DLVH_UPD_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCDL/DL_DLVH_UPD_STR INTO WA_/SCDL/DL_DLVH_UPD_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCDL/DL_DLVH_UPD_STR-DOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCDL/DL_DLVH_UPD_STR-DOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CRETST CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCDL/DL_DLVH_UPD_STR-CRETST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCDL/DL_DLVH_UPD_STR-CRETST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CHGTST CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCDL/DL_DLVH_UPD_STR-CHGTST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCDL/DL_DLVH_UPD_STR-CHGTST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCDL/DL_DLVH_UPD_STR_STR,
MANDT TYPE STRING,
DOCID TYPE STRING,
DOCCAT TYPE STRING,
DOCTYPE TYPE STRING,
DOCNO TYPE STRING,
CRETST TYPE STRING,
CREUSR TYPE STRING,
CHGTST TYPE STRING,
CHGUSR TYPE STRING,
CHGVERSION TYPE STRING,
MANUAL TYPE STRING,
INCO1 TYPE STRING,
INCO2 TYPE STRING,
TEXTIND TYPE STRING,
TMI_IND TYPE STRING,
SAP TYPE STRING,
/SCWM/UNIT_SYST TYPE STRING,
/SCWM/CORRIND TYPE STRING,
/SCWM/PRODIND TYPE STRING,
/SCWM/COMMIND TYPE STRING,
/SCWM/LOG_PROCESS TYPE STRING,
/SCWM/TMIND TYPE STRING,
TW_STOP_ID TYPE STRING,
/SCWM/CUST_IND TYPE STRING,
/SCWM/NO_REFIND TYPE STRING,
/SCWM/SCRAPPIND TYPE STRING,
/SCWM/PICKUPIND TYPE STRING,
/SCWM/INV_GIIND TYPE STRING,
VKORG TYPE STRING,
/SCWM/LGLC_IND TYPE STRING,
/SCDL/DLV_HEAD TYPE STRING,
OBJCHG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCDL/DL_DLVH_UPD_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-MANDT sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-DOCID sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-DOCCAT sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-DOCTYPE sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-DOCNO sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-CRETST sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-CREUSR sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-CHGTST sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-CHGUSR sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-CHGVERSION sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-MANUAL sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-INCO1 sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-INCO2 sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-TEXTIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-TMI_IND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-SAP sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/UNIT_SYST sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/CORRIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/PRODIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/COMMIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/LOG_PROCESS sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/TMIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-TW_STOP_ID sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/CUST_IND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/NO_REFIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/SCRAPPIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/PICKUPIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/INV_GIIND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-VKORG sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCWM/LGLC_IND sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-/SCDL/DLV_HEAD sy-vline
WA_/SCDL/DL_DLVH_UPD_STR_STR-OBJCHG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.