ABAP Select data from SAP table /SAPSRM/S_CLL_WD_DS_SC_RESULT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPSRM/S_CLL_WD_DS_SC_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPSRM/S_CLL_WD_DS_SC_RESULT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPSRM/S_CLL_WD_DS_SC_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT TYPE STANDARD TABLE OF /SAPSRM/S_CLL_WD_DS_SC_RESULT,
      WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT TYPE /SAPSRM/S_CLL_WD_DS_SC_RESULT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPSRM/S_CLL_WD_DS_SC_RESULT> TYPE /SAPSRM/S_CLL_WD_DS_SC_RESULT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPSRM/S_CLL_WD_DS_SC_RESULT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPSRM/S_CLL_WD_DS_SC_RESULT
  INTO TABLE IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPSRM/S_CLL_WD_DS_SC_RESULT
*  INTO TABLE @DATA(IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT INDEX 1 INTO DATA(WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT ASSIGNING </SAPSRM/S_CLL_WD_DS_SC_RESULT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPSRM/S_CLL_WD_DS_SC_RESULT>-MARK = 1.
</SAPSRM/S_CLL_WD_DS_SC_RESULT>-OBJECT_ID = 1.
</SAPSRM/S_CLL_WD_DS_SC_RESULT>-DESCRIPTION = 1.
</SAPSRM/S_CLL_WD_DS_SC_RESULT>-POSTING_DATE = 1.
</SAPSRM/S_CLL_WD_DS_SC_RESULT>-CURRENCY = 1.
ENDLOOP.

LOOP AT IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT INTO WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-TOTAL_VALUE, sy-vline,
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-TOTAL_TAX, sy-vline,
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-TOTAL_VALUE_APPR, sy-vline,
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-STEXT, sy-vline,
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-CHANGEABLE, sy-vline,
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-ERASABLE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPSRM/S_CLL_WD_DS_SC_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPSRM/S_CLL_WD_DS_SC_RESULT INTO WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field OBJECT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-OBJECT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-OBJECT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-CREATED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-CREATED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-CHANGED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT-CHANGED_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR,
MARK TYPE STRING,
OBJECT_ID TYPE STRING,
DESCRIPTION TYPE STRING,
POSTING_DATE TYPE STRING,
CURRENCY TYPE STRING,
TOTAL_VALUE TYPE STRING,
TOTAL_TAX TYPE STRING,
TOTAL_VALUE_APPR TYPE STRING,
STEXT TYPE STRING,
CHANGEABLE TYPE STRING,
ERASABLE TYPE STRING,
PRINTABLE TYPE STRING,
DUMMY_EEW_PD_SEARCH_HSS_SC TYPE STRING,
PS_PARK_IND TYPE STRING,
PS_US01 TYPE STRING,
PS_US02 TYPE STRING,
PS_US03 TYPE STRING,
PS_US04 TYPE STRING,
PS_US05 TYPE STRING,
PS_US06 TYPE STRING,
PS_US07 TYPE STRING,
PS_US08 TYPE STRING,
PS_US09 TYPE STRING,
PS_US10 TYPE STRING,
PS_IPT TYPE STRING,
EXLIN TYPE STRING,
PS_US01_TXT TYPE STRING,
PS_US02_TXT TYPE STRING,
PS_US03_TXT TYPE STRING,
PS_US04_TXT TYPE STRING,
PS_US05_TXT TYPE STRING,
PS_US06_TXT TYPE STRING,
PS_US07_TXT TYPE STRING,
PS_US08_TXT TYPE STRING,
PS_US09_TXT TYPE STRING,
PS_US10_TXT TYPE STRING,
DUMMY_EEW_PD_SEARCH_HSC_SC TYPE STRING,
TEAM TYPE STRING,
GUID TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
SUBTYPE TYPE STRING,
PROCESS_TYPE TYPE STRING,
TZONE TYPE STRING,
LINE_NUMBER TYPE STRING,
EXPANDED TYPE STRING,
STATUS TYPE STRING,
OBJECT_TYPE TYPE STRING,
PROC_ORG TYPE STRING,
PROC_GROUP TYPE STRING,
STATUS_LONG TYPE STRING,
H_GUID TYPE STRING,
P_GUID TYPE STRING,
TABLE_CAPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-MARK sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-OBJECT_ID sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-DESCRIPTION sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-POSTING_DATE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CURRENCY sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TOTAL_VALUE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TOTAL_TAX sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TOTAL_VALUE_APPR sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-STEXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CHANGEABLE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-ERASABLE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PRINTABLE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-DUMMY_EEW_PD_SEARCH_HSS_SC sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_PARK_IND sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US01 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US02 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US03 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US04 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US05 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US06 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US07 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US08 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US09 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US10 sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_IPT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-EXLIN sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US01_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US02_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US03_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US04_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US05_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US06_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US07_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US08_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US09_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PS_US10_TXT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-DUMMY_EEW_PD_SEARCH_HSC_SC sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TEAM sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-GUID sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CREATED_BY sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CREATED_AT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CHANGED_BY sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-CHANGED_AT sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-SUBTYPE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PROCESS_TYPE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TZONE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-LINE_NUMBER sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-EXPANDED sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-STATUS sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-OBJECT_TYPE sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PROC_ORG sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-PROC_GROUP sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-STATUS_LONG sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-H_GUID sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-P_GUID sy-vline
WA_/SAPSRM/S_CLL_WD_DS_SC_RESULT_STR-TABLE_CAPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.