ABAP Select data from SAP table /SAPNEA/J_SC_RBSEG_ST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPNEA/J_SC_RBSEG_ST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPNEA/J_SC_RBSEG_ST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPNEA/J_SC_RBSEG_ST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPNEA/J_SC_RBSEG_ST TYPE STANDARD TABLE OF /SAPNEA/J_SC_RBSEG_ST,
      WA_/SAPNEA/J_SC_RBSEG_ST TYPE /SAPNEA/J_SC_RBSEG_ST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPNEA/J_SC_RBSEG_ST> TYPE /SAPNEA/J_SC_RBSEG_ST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPNEA/J_SC_RBSEG_ST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPNEA/J_SC_RBSEG_ST
  INTO TABLE IT_/SAPNEA/J_SC_RBSEG_ST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPNEA/J_SC_RBSEG_ST
*  INTO TABLE @DATA(IT_/SAPNEA/J_SC_RBSEG_ST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPNEA/J_SC_RBSEG_ST INDEX 1 INTO DATA(WA_/SAPNEA/J_SC_RBSEG_ST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPNEA/J_SC_RBSEG_ST ASSIGNING </SAPNEA/J_SC_RBSEG_ST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPNEA/J_SC_RBSEG_ST>-ANLN1 = 1.
</SAPNEA/J_SC_RBSEG_ST>-ANLN2 = 1.
</SAPNEA/J_SC_RBSEG_ST>-APLZL = 1.
</SAPNEA/J_SC_RBSEG_ST>-AUFNR = 1.
</SAPNEA/J_SC_RBSEG_ST>-AUFPL = 1.
ENDLOOP.

LOOP AT IT_/SAPNEA/J_SC_RBSEG_ST INTO WA_/SAPNEA/J_SC_RBSEG_ST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPNEA/J_SC_RBSEG_ST-BEWAR, sy-vline,
WA_/SAPNEA/J_SC_RBSEG_ST-BPMNG, sy-vline,
WA_/SAPNEA/J_SC_RBSEG_ST-BUZID, sy-vline,
WA_/SAPNEA/J_SC_RBSEG_ST-BWKEY, sy-vline,
WA_/SAPNEA/J_SC_RBSEG_ST-BWTAR, sy-vline,
WA_/SAPNEA/J_SC_RBSEG_ST-BZDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPNEA/J_SC_RBSEG_ST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPNEA/J_SC_RBSEG_ST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPNEA/J_SC_RBSEG_ST INTO WA_/SAPNEA/J_SC_RBSEG_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMPFB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-EMPFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-EMPFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ESRRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-ESRRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-ESRRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FILKD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-FILKD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-FILKD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIS, internal->external for field FIPOS CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-FIPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-FIPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-KBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-KBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LFBNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-LFBNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-LFBNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field LFGJA CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-LFGJA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-LFGJA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NPLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-NPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-NPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-PPRCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-PPRCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REBZJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-REBZJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-REBZJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-RECID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-RECID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBEL2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-VBEL2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-VBEL2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBUND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-VBUND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-VBUND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VPTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-VPTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-VPTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RBELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-RBELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-RBELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPNEA/J_SC_RBSEG_ST-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPNEA/J_SC_RBSEG_ST-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPNEA/J_SC_RBSEG_ST_STR,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
APLZL TYPE STRING,
AUFNR TYPE STRING,
AUFPL TYPE STRING,
BEWAR TYPE STRING,
BPMNG TYPE STRING,
BUZID TYPE STRING,
BWKEY TYPE STRING,
BWTAR TYPE STRING,
BZDAT TYPE STRING,
DIEKZ TYPE STRING,
DMBTR TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
EMPFB TYPE STRING,
EREKZ TYPE STRING,
ESRNR TYPE STRING,
ESRPZ TYPE STRING,
ESRRE TYPE STRING,
ETEN2 TYPE STRING,
FILKD TYPE STRING,
FIPOS TYPE STRING,
FISTL TYPE STRING,
FKBER TYPE STRING,
FKONT TYPE STRING,
FRATH TYPE STRING,
FWBAS TYPE STRING,
GEBER TYPE STRING,
GSBER TYPE STRING,
GUTSC TYPE STRING,
IMKEY TYPE STRING,
KBLNR TYPE STRING,
KBLPOS TYPE STRING,
KOART TYPE STRING,
KSTRG TYPE STRING,
LANDL TYPE STRING,
LFBNR TYPE STRING,
LFGJA TYPE STRING,
LFPOS TYPE STRING,
LIFNR TYPE STRING,
LZBKZ TYPE STRING,
KOSTL TYPE STRING,
KTOSL TYPE STRING,
MATNR TYPE STRING,
MENGE TYPE STRING,
MWSKZ TYPE STRING,
NPLNR TYPE STRING,
PAOBJNR TYPE STRING,
PARGB TYPE STRING,
PERNR TYPE STRING,
POSN2 TYPE STRING,
PPRCT TYPE STRING,
PRCTR TYPE STRING,
PROJK TYPE STRING,
PSTYP TYPE STRING,
QSFBT TYPE STRING,
QSSHB TYPE STRING,
QSSKZ TYPE STRING,
REBZG TYPE STRING,
REBZJ TYPE STRING,
REBZZ TYPE STRING,
RECHN TYPE STRING,
RECID TYPE STRING,
REUPD TYPE STRING,
SAKNR TYPE STRING,
SAKTO TYPE STRING,
SGTXT TYPE STRING,
SHKZG TYPE STRING,
SKFBT TYPE STRING,
STUNR TYPE STRING,
TBTKZ TYPE STRING,
TXJCD TYPE STRING,
XCPDD TYPE STRING,
VBEL2 TYPE STRING,
VBUND TYPE STRING,
VPTNR TYPE STRING,
WMWST TYPE STRING,
WRBTR TYPE STRING,
WSKTO TYPE STRING,
XSKRL TYPE STRING,
ZAEHK TYPE STRING,
ZBD1P TYPE STRING,
ZBD1T TYPE STRING,
ZBD2P TYPE STRING,
ZBD2T TYPE STRING,
ZBD3T TYPE STRING,
ZEKKN TYPE STRING,
ZFBDT TYPE STRING,
ZLSCH TYPE STRING,
ZLSPR TYPE STRING,
ZOLLD TYPE STRING,
ZOLLT TYPE STRING,
ZTERM TYPE STRING,
ZUONR TYPE STRING,
UZAWE TYPE STRING,
DABRZ TYPE STRING,
RBELNR TYPE STRING,
RBUZEI TYPE STRING,
WERKS TYPE STRING,
XINVE TYPE STRING,
GRANT_NBR TYPE STRING,
BUDGET_PD TYPE STRING,
WRBTR_SC TYPE STRING,
WMWST_SC TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPNEA/J_SC_RBSEG_ST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ANLN1 sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ANLN2 sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-APLZL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-AUFNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-AUFPL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BEWAR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BPMNG sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BUZID sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BWKEY sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BWTAR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BZDAT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-DIEKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-DMBTR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-EBELN sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-EBELP sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-EMPFB sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-EREKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ESRNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ESRPZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ESRRE sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ETEN2 sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FILKD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FIPOS sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FISTL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FKBER sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FKONT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FRATH sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-FWBAS sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-GEBER sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-GSBER sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-GUTSC sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-IMKEY sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KBLNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KBLPOS sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KOART sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KSTRG sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LANDL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LFBNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LFGJA sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LFPOS sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LIFNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-LZBKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KOSTL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-KTOSL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-MATNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-MENGE sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-MWSKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-NPLNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PAOBJNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PARGB sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PERNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-POSN2 sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PPRCT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PRCTR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PROJK sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-PSTYP sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-QSFBT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-QSSHB sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-QSSKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-REBZG sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-REBZJ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-REBZZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-RECHN sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-RECID sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-REUPD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-SAKNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-SAKTO sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-SGTXT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-SHKZG sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-SKFBT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-STUNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-TBTKZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-TXJCD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-XCPDD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-VBEL2 sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-VBUND sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-VPTNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WMWST sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WRBTR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WSKTO sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-XSKRL sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZAEHK sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZBD1P sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZBD1T sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZBD2P sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZBD2T sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZBD3T sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZEKKN sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZFBDT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZLSCH sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZLSPR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZOLLD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZOLLT sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZTERM sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-ZUONR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-UZAWE sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-DABRZ sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-RBELNR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-RBUZEI sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WERKS sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-XINVE sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-GRANT_NBR sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-BUDGET_PD sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WRBTR_SC sy-vline
WA_/SAPNEA/J_SC_RBSEG_ST_STR-WMWST_SC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.