ABAP Select data from SAP table /SAPMP/RCGLOBALCNTRL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPMP/RCGLOBALCNTRL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPMP/RCGLOBALCNTRL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPMP/RCGLOBALCNTRL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPMP/RCGLOBALCNTRL TYPE STANDARD TABLE OF /SAPMP/RCGLOBALCNTRL,
      WA_/SAPMP/RCGLOBALCNTRL TYPE /SAPMP/RCGLOBALCNTRL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPMP/RCGLOBALCNTRL> TYPE /SAPMP/RCGLOBALCNTRL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPMP/RCGLOBALCNTRL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPMP/RCGLOBALCNTRL
  INTO TABLE IT_/SAPMP/RCGLOBALCNTRL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPMP/RCGLOBALCNTRL
*  INTO TABLE @DATA(IT_/SAPMP/RCGLOBALCNTRL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPMP/RCGLOBALCNTRL INDEX 1 INTO DATA(WA_/SAPMP/RCGLOBALCNTRL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPMP/RCGLOBALCNTRL ASSIGNING </SAPMP/RCGLOBALCNTRL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPMP/RCGLOBALCNTRL>-MATNR = 1.
</SAPMP/RCGLOBALCNTRL>-WERKS = 1.
</SAPMP/RCGLOBALCNTRL>-MRESET = 1.
</SAPMP/RCGLOBALCNTRL>-FCODE = 1.
</SAPMP/RCGLOBALCNTRL>-INDAP = 1.
ENDLOOP.

LOOP AT IT_/SAPMP/RCGLOBALCNTRL INTO WA_/SAPMP/RCGLOBALCNTRL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPMP/RCGLOBALCNTRL-PMODE, sy-vline,
WA_/SAPMP/RCGLOBALCNTRL-ROFNVL, sy-vline,
WA_/SAPMP/RCGLOBALCNTRL-PCDRFT, sy-vline,
WA_/SAPMP/RCGLOBALCNTRL-FCDVL, sy-vline,
WA_/SAPMP/RCGLOBALCNTRL-NAWFA, sy-vline,
WA_/SAPMP/RCGLOBALCNTRL-ULCAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPMP/RCGLOBALCNTRL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPMP/RCGLOBALCNTRL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPMP/RCGLOBALCNTRL INTO WA_/SAPMP/RCGLOBALCNTRL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SAPMP/RCGLOBALCNTRL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPMP/RCGLOBALCNTRL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ULCAL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPMP/RCGLOBALCNTRL-ULCAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPMP/RCGLOBALCNTRL-ULCAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UDCAL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPMP/RCGLOBALCNTRL-UDCAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPMP/RCGLOBALCNTRL-UDCAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UWCAL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPMP/RCGLOBALCNTRL-UWCAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPMP/RCGLOBALCNTRL-UWCAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPMP/RCGLOBALCNTRL_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
MRESET TYPE STRING,
FCODE TYPE STRING,
INDAP TYPE STRING,
PMODE TYPE STRING,
ROFNVL TYPE STRING,
PCDRFT TYPE STRING,
FCDVL TYPE STRING,
NAWFA TYPE STRING,
ULCAL TYPE STRING,
UDCAL TYPE STRING,
UWCAL TYPE STRING,
CDMLT TYPE STRING,
CLGT1 TYPE STRING,
CDMGE TYPE STRING,
CLGT2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPMP/RCGLOBALCNTRL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-MATNR sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-WERKS sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-MRESET sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-FCODE sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-INDAP sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-PMODE sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-ROFNVL sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-PCDRFT sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-FCDVL sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-NAWFA sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-ULCAL sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-UDCAL sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-UWCAL sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-CDMLT sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-CLGT1 sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-CDMGE sy-vline
WA_/SAPMP/RCGLOBALCNTRL_STR-CLGT2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.