ABAP Select data from SAP table /PM0/ABEOIOTABDC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABEOIOTABDC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABEOIOTABDC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ABEOIOTABDC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ABEOIOTABDC TYPE STANDARD TABLE OF /PM0/ABEOIOTABDC,
      WA_/PM0/ABEOIOTABDC TYPE /PM0/ABEOIOTABDC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ABEOIOTABDC> TYPE /PM0/ABEOIOTABDC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ABEOIOTABDC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ABEOIOTABDC
  INTO TABLE IT_/PM0/ABEOIOTABDC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ABEOIOTABDC
*  INTO TABLE @DATA(IT_/PM0/ABEOIOTABDC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ABEOIOTABDC INDEX 1 INTO DATA(WA_/PM0/ABEOIOTABDC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ABEOIOTABDC ASSIGNING </PM0/ABEOIOTABDC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABEOIOTABDC>-/PM0/ABDOINSOBJ_OID = 1.
</PM0/ABEOIOTABDC>-EFFECTIVITY_DT = 1.
</PM0/ABEOIOTABDC>-INSOBJ_TT = 1.
</PM0/ABEOIOTABDC>-OBJCAT_CD = 1.
</PM0/ABEOIOTABDC>-OBJTYP_CD = 1.
ENDLOOP.

LOOP AT IT_/PM0/ABEOIOTABDC INTO WA_/PM0/ABEOIOTABDC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ABEOIOTABDC-INSOBJNR_TT, sy-vline,
WA_/PM0/ABEOIOTABDC-OBJTYPTO_ID, sy-vline,
WA_/PM0/ABEOIOTABDC-INSOBJECT_TT, sy-vline,
WA_/PM0/ABEOIOTABDC-PART_ID, sy-vline,
WA_/PM0/ABEOIOTABDC-CURRENCY_ID, sy-vline,
WA_/PM0/ABEOIOTABDC-INSDECNR_TT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABEOIOTABDC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABEOIOTABDC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABEOIOTABDC INTO WA_/PM0/ABEOIOTABDC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSOBJNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-INSOBJNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-INSOBJNR_TT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PART_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-PART_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-PART_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSDECNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-INSDECNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-INSDECNR_TT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXTOBJNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-EXTOBJNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-EXTOBJNR_TT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field POSGRP_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-POSGRP_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-POSGRP_TT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-PARTN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-PARTN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESIDENTSPACE_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-RESIDENTSPACE_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-RESIDENTSPACE_UT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GLAZEDAREABUI_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-GLAZEDAREABUI_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-GLAZEDAREABUI_UT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INTERIORGLAZ_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTABDC-INTERIORGLAZ_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTABDC-INTERIORGLAZ_UT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABEOIOTABDC_STR,
/PM0/ABDOINSOBJ_OID TYPE STRING,
EFFECTIVITY_DT TYPE STRING,
INSOBJ_TT TYPE STRING,
OBJCAT_CD TYPE STRING,
OBJTYP_CD TYPE STRING,
INSOBJNR_TT TYPE STRING,
OBJTYPTO_ID TYPE STRING,
INSOBJECT_TT TYPE STRING,
PART_ID TYPE STRING,
CURRENCY_ID TYPE STRING,
INSDECNR_TT TYPE STRING,
OBJPOSNR_TT TYPE STRING,
EXTOBJNR_TT TYPE STRING,
STATUS_ID TYPE STRING,
CANCEL_TT TYPE STRING,
CANCEL_DT TYPE STRING,
/PM0/ABDOINSOBJ_CID TYPE STRING,
CHANGEREASON_ID TYPE STRING,
CHANGEREASON_TT TYPE STRING,
CHAREATXT_TT TYPE STRING,
OBJCAT_TT TYPE STRING,
OBJGRP_TT TYPE STRING,
OBJTYP_TT TYPE STRING,
POSGRP_TT TYPE STRING,
CUSTOMER_TB_CI TYPE STRING,
RESIDENTSPACE_VL TYPE STRING,
OUTERWALL_CD TYPE STRING,
GLAZEDAREABUI_VL TYPE STRING,
INTERIORGLAZ_VL TYPE STRING,
PREFABRIHOUSE_FG TYPE STRING,
ROOFING_CD TYPE STRING,
LOCBUILTAREA_FG TYPE STRING,
PARTN_ID TYPE STRING,
INTCOVCONF_FG TYPE STRING,
PARTNERACT_ID TYPE STRING,
RESIDENTSPACE_UT TYPE STRING,
GLAZEDAREABUI_UT TYPE STRING,
INTERIORGLAZ_UT TYPE STRING,
CUSTOMER_PB_CI TYPE STRING,
OUTERWALL_TT TYPE STRING,
PARTNERACT_TT TYPE STRING,
PARTNERNAME_TT TYPE STRING,
ROOFING_TT TYPE STRING,
DUMMY TYPE STRING,
CUSTOMER_ABDC_CI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABEOIOTABDC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABEOIOTABDC_STR-/PM0/ABDOINSOBJ_OID sy-vline
WA_/PM0/ABEOIOTABDC_STR-EFFECTIVITY_DT sy-vline
WA_/PM0/ABEOIOTABDC_STR-INSOBJ_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJCAT_CD sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJTYP_CD sy-vline
WA_/PM0/ABEOIOTABDC_STR-INSOBJNR_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJTYPTO_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-INSOBJECT_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-PART_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-CURRENCY_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-INSDECNR_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJPOSNR_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-EXTOBJNR_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-STATUS_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-CANCEL_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-CANCEL_DT sy-vline
WA_/PM0/ABEOIOTABDC_STR-/PM0/ABDOINSOBJ_CID sy-vline
WA_/PM0/ABEOIOTABDC_STR-CHANGEREASON_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-CHANGEREASON_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-CHAREATXT_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJCAT_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJGRP_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-OBJTYP_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-POSGRP_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-CUSTOMER_TB_CI sy-vline
WA_/PM0/ABEOIOTABDC_STR-RESIDENTSPACE_VL sy-vline
WA_/PM0/ABEOIOTABDC_STR-OUTERWALL_CD sy-vline
WA_/PM0/ABEOIOTABDC_STR-GLAZEDAREABUI_VL sy-vline
WA_/PM0/ABEOIOTABDC_STR-INTERIORGLAZ_VL sy-vline
WA_/PM0/ABEOIOTABDC_STR-PREFABRIHOUSE_FG sy-vline
WA_/PM0/ABEOIOTABDC_STR-ROOFING_CD sy-vline
WA_/PM0/ABEOIOTABDC_STR-LOCBUILTAREA_FG sy-vline
WA_/PM0/ABEOIOTABDC_STR-PARTN_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-INTCOVCONF_FG sy-vline
WA_/PM0/ABEOIOTABDC_STR-PARTNERACT_ID sy-vline
WA_/PM0/ABEOIOTABDC_STR-RESIDENTSPACE_UT sy-vline
WA_/PM0/ABEOIOTABDC_STR-GLAZEDAREABUI_UT sy-vline
WA_/PM0/ABEOIOTABDC_STR-INTERIORGLAZ_UT sy-vline
WA_/PM0/ABEOIOTABDC_STR-CUSTOMER_PB_CI sy-vline
WA_/PM0/ABEOIOTABDC_STR-OUTERWALL_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-PARTNERACT_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-PARTNERNAME_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-ROOFING_TT sy-vline
WA_/PM0/ABEOIOTABDC_STR-DUMMY sy-vline
WA_/PM0/ABEOIOTABDC_STR-CUSTOMER_ABDC_CI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.