ABAP Select data from SAP table /PM0/ABC_IBC_BASIC_CHANNEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABC_IBC_BASIC_CHANNEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABC_IBC_BASIC_CHANNEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ABC_IBC_BASIC_CHANNEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ABC_IBC_BASIC_CHANNEL TYPE STANDARD TABLE OF /PM0/ABC_IBC_BASIC_CHANNEL,
      WA_/PM0/ABC_IBC_BASIC_CHANNEL TYPE /PM0/ABC_IBC_BASIC_CHANNEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ABC_IBC_BASIC_CHANNEL> TYPE /PM0/ABC_IBC_BASIC_CHANNEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ABC_IBC_BASIC_CHANNEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ABC_IBC_BASIC_CHANNEL
  INTO TABLE IT_/PM0/ABC_IBC_BASIC_CHANNEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ABC_IBC_BASIC_CHANNEL
*  INTO TABLE @DATA(IT_/PM0/ABC_IBC_BASIC_CHANNEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ABC_IBC_BASIC_CHANNEL INDEX 1 INTO DATA(WA_/PM0/ABC_IBC_BASIC_CHANNEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ABC_IBC_BASIC_CHANNEL ASSIGNING </PM0/ABC_IBC_BASIC_CHANNEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABC_IBC_BASIC_CHANNEL>-APPLICATION_ID = 1.
</PM0/ABC_IBC_BASIC_CHANNEL>-TEMPLATE_ID = 1.
</PM0/ABC_IBC_BASIC_CHANNEL>-STATE_CD = 1.
</PM0/ABC_IBC_BASIC_CHANNEL>-SALESDATE_FROM = 1.
</PM0/ABC_IBC_BASIC_CHANNEL>-SALESDATE_TO = 1.
ENDLOOP.

LOOP AT IT_/PM0/ABC_IBC_BASIC_CHANNEL INTO WA_/PM0/ABC_IBC_BASIC_CHANNEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ABC_IBC_BASIC_CHANNEL-ENTITYTYPE, sy-vline,
WA_/PM0/ABC_IBC_BASIC_CHANNEL-ENTITYTYPE_TT, sy-vline,
WA_/PM0/ABC_IBC_BASIC_CHANNEL-PRODUCT, sy-vline,
WA_/PM0/ABC_IBC_BASIC_CHANNEL-PRODUCTMAPPING, sy-vline,
WA_/PM0/ABC_IBC_BASIC_CHANNEL-LONGTEXT_TT, sy-vline,
WA_/PM0/ABC_IBC_BASIC_CHANNEL-SHORTTEXT_TT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABC_IBC_BASIC_CHANNEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABC_IBC_BASIC_CHANNEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABC_IBC_BASIC_CHANNEL INTO WA_/PM0/ABC_IBC_BASIC_CHANNEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABC_IBC_BASIC_CHANNEL_STR,
APPLICATION_ID TYPE STRING,
TEMPLATE_ID TYPE STRING,
STATE_CD TYPE STRING,
SALESDATE_FROM TYPE STRING,
SALESDATE_TO TYPE STRING,
ENTITYTYPE TYPE STRING,
ENTITYTYPE_TT TYPE STRING,
PRODUCT TYPE STRING,
PRODUCTMAPPING TYPE STRING,
LONGTEXT_TT TYPE STRING,
SHORTTEXT_TT TYPE STRING,
TEMPLATE_TYPE TYPE STRING,
TEMPLATE_TYPE_TT TYPE STRING,
TEMPLATE_GRP TYPE STRING,
TEMPLATE_GRP_TT TYPE STRING,
IS_ONLY_USED_IN_MASTPOL TYPE STRING,
WRITEPROTECT_TMLT_FG TYPE STRING,
EDITOR TYPE STRING,
CHECKER TYPE STRING,
REJECTREASON_TT TYPE STRING,
PREFERRED_TMPL_FG TYPE STRING,
SRCPRDENG_CD TYPE STRING,
TMPL_LAST_CHANGED_DATE TYPE STRING,
TMPL_LAST_CHANGED_TIME TYPE STRING,
TMPL_LAST_CHANGED_UNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-APPLICATION_ID sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TEMPLATE_ID sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-STATE_CD sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-SALESDATE_FROM sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-SALESDATE_TO sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-ENTITYTYPE sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-ENTITYTYPE_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-PRODUCT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-PRODUCTMAPPING sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-LONGTEXT_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-SHORTTEXT_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TEMPLATE_TYPE sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TEMPLATE_TYPE_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TEMPLATE_GRP sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TEMPLATE_GRP_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-IS_ONLY_USED_IN_MASTPOL sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-WRITEPROTECT_TMLT_FG sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-EDITOR sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-CHECKER sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-REJECTREASON_TT sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-PREFERRED_TMPL_FG sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-SRCPRDENG_CD sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TMPL_LAST_CHANGED_DATE sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TMPL_LAST_CHANGED_TIME sy-vline
WA_/PM0/ABC_IBC_BASIC_CHANNEL_STR-TMPL_LAST_CHANGED_UNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.