ABAP Select data from SAP table /PLMU/S_PPE_CMP_TO_VC2OD_DMT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMU/S_PPE_CMP_TO_VC2OD_DMT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMU/S_PPE_CMP_TO_VC2OD_DMT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMU/S_PPE_CMP_TO_VC2OD_DMT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT TYPE STANDARD TABLE OF /PLMU/S_PPE_CMP_TO_VC2OD_DMT,
      WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT TYPE /PLMU/S_PPE_CMP_TO_VC2OD_DMT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMU/S_PPE_CMP_TO_VC2OD_DMT> TYPE /PLMU/S_PPE_CMP_TO_VC2OD_DMT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMU/S_PPE_CMP_TO_VC2OD_DMT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMU/S_PPE_CMP_TO_VC2OD_DMT
  INTO TABLE IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMU/S_PPE_CMP_TO_VC2OD_DMT
*  INTO TABLE @DATA(IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT INDEX 1 INTO DATA(WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT ASSIGNING </PLMU/S_PPE_CMP_TO_VC2OD_DMT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMU/S_PPE_CMP_TO_VC2OD_DMT>-NODE_NAME = 1.
</PLMU/S_PPE_CMP_TO_VC2OD_DMT>-VARIANT_NAME = 1.
</PLMU/S_PPE_CMP_TO_VC2OD_DMT>-VARIANT_TEXT = 1.
</PLMU/S_PPE_CMP_TO_VC2OD_DMT>-CHANGE_NUMBER_LOCKED = 1.
</PLMU/S_PPE_CMP_TO_VC2OD_DMT>-DELETION_FLAG = 1.
ENDLOOP.

LOOP AT IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT INTO WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-STDVAR, sy-vline,
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-OBJECT_TYPE, sy-vline,
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-GUID, sy-vline,
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-ECN_COUNTER, sy-vline,
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-ASSIGNMENT_NO, sy-vline,
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-LEAD_OBJ_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMU/S_PPE_CMP_TO_VC2OD_DMT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMU/S_PPE_CMP_TO_VC2OD_DMT INTO WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VARIANT_NAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-VARIANT_NAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-VARIANT_NAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-CHANGE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-CHANGE_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSTANCE_NAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-INSTANCE_NAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT-INSTANCE_NAME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR,
NODE_NAME TYPE STRING,
VARIANT_NAME TYPE STRING,
VARIANT_TEXT TYPE STRING,
CHANGE_NUMBER_LOCKED TYPE STRING,
DELETION_FLAG TYPE STRING,
STDVAR TYPE STRING,
OBJECT_TYPE TYPE STRING,
GUID TYPE STRING,
ECN_COUNTER TYPE STRING,
ASSIGNMENT_NO TYPE STRING,
LEAD_OBJ_TYPE TYPE STRING,
CHANGE_NUMBER TYPE STRING,
LEAD_OBJECT_IS_CHANGEABLE TYPE STRING,
KEY_DATE TYPE STRING,
DUMMY TYPE STRING,
MATERIAL TYPE STRING,
INSTANCE_NAME TYPE STRING,
INSTANCE_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-NODE_NAME sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-VARIANT_NAME sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-VARIANT_TEXT sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-CHANGE_NUMBER_LOCKED sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-DELETION_FLAG sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-STDVAR sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-OBJECT_TYPE sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-GUID sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-ECN_COUNTER sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-ASSIGNMENT_NO sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-LEAD_OBJ_TYPE sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-CHANGE_NUMBER sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-LEAD_OBJECT_IS_CHANGEABLE sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-KEY_DATE sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-DUMMY sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-MATERIAL sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-INSTANCE_NAME sy-vline
WA_/PLMU/S_PPE_CMP_TO_VC2OD_DMT_STR-INSTANCE_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.