ABAP Select data from SAP table /PLMI/S_RCA_COMP_BUFF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMI/S_RCA_COMP_BUFF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMI/S_RCA_COMP_BUFF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMI/S_RCA_COMP_BUFF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMI/S_RCA_COMP_BUFF TYPE STANDARD TABLE OF /PLMI/S_RCA_COMP_BUFF,
      WA_/PLMI/S_RCA_COMP_BUFF TYPE /PLMI/S_RCA_COMP_BUFF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMI/S_RCA_COMP_BUFF> TYPE /PLMI/S_RCA_COMP_BUFF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMI/S_RCA_COMP_BUFF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMI/S_RCA_COMP_BUFF
  INTO TABLE IT_/PLMI/S_RCA_COMP_BUFF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMI/S_RCA_COMP_BUFF
*  INTO TABLE @DATA(IT_/PLMI/S_RCA_COMP_BUFF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMI/S_RCA_COMP_BUFF INDEX 1 INTO DATA(WA_/PLMI/S_RCA_COMP_BUFF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMI/S_RCA_COMP_BUFF ASSIGNING </PLMI/S_RCA_COMP_BUFF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMI/S_RCA_COMP_BUFF>-CALC_ID = 1.
</PLMI/S_RCA_COMP_BUFF>-PARENT_SUBST_ID = 1.
</PLMI/S_RCA_COMP_BUFF>-SUBRECN_ROOT = 1.
</PLMI/S_RCA_COMP_BUFF>-RCP_GUID = 1.
</PLMI/S_RCA_COMP_BUFF>-ITEM = 1.
ENDLOOP.

LOOP AT IT_/PLMI/S_RCA_COMP_BUFF INTO WA_/PLMI/S_RCA_COMP_BUFF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMI/S_RCA_COMP_BUFF-SUBID, sy-vline,
WA_/PLMI/S_RCA_COMP_BUFF-QUANTITY, sy-vline,
WA_/PLMI/S_RCA_COMP_BUFF-UOM, sy-vline,
WA_/PLMI/S_RCA_COMP_BUFF-SUBRECN, sy-vline,
WA_/PLMI/S_RCA_COMP_BUFF-SUBST_DESCR_1, sy-vline,
WA_/PLMI/S_RCA_COMP_BUFF-SUBST_DESCR_2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMI/S_RCA_COMP_BUFF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMI/S_RCA_COMP_BUFF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMI/S_RCA_COMP_BUFF INTO WA_/PLMI/S_RCA_COMP_BUFF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_COMP_BUFF-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_COMP_BUFF-UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMI/S_RCA_COMP_BUFF_STR,
CALC_ID TYPE STRING,
PARENT_SUBST_ID TYPE STRING,
SUBRECN_ROOT TYPE STRING,
RCP_GUID TYPE STRING,
ITEM TYPE STRING,
SUBID TYPE STRING,
QUANTITY TYPE STRING,
UOM TYPE STRING,
SUBRECN TYPE STRING,
SUBST_DESCR_1 TYPE STRING,
SUBST_DESCR_2 TYPE STRING,
ROLE TYPE STRING,
ROLENAME TYPE STRING,
COMPTGT_CALC TYPE STRING,
COMPTGT_FLT_CALC TYPE STRING,
COMPTGT_CALC_PRINT TYPE STRING,
UNIT_CALC TYPE STRING,
EXCVAL_CALC TYPE STRING,
EXCVAL_CALC_TXT TYPE STRING,
COMPTGT_SPEC TYPE STRING,
UNIT_SPEC TYPE STRING,
COMPTGT_SPEC_PRINT TYPE STRING,
EXCVAL_SPEC TYPE STRING,
EXCVAL_SPEC_TXT TYPE STRING,
VARIANT_KEY TYPE STRING,
COMPTGT_FLT TYPE STRING,
DUMMY TYPE STRING,
MODIFIED TYPE STRING,
STD_COMP TYPE STRING,
ITEM_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMI/S_RCA_COMP_BUFF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-CALC_ID sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-PARENT_SUBST_ID sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-SUBRECN_ROOT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-RCP_GUID sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-ITEM sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-SUBID sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-QUANTITY sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-UOM sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-SUBRECN sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-SUBST_DESCR_1 sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-SUBST_DESCR_2 sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-ROLE sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-ROLENAME sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_CALC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_FLT_CALC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_CALC_PRINT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-UNIT_CALC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-EXCVAL_CALC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-EXCVAL_CALC_TXT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_SPEC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-UNIT_SPEC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_SPEC_PRINT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-EXCVAL_SPEC sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-EXCVAL_SPEC_TXT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-VARIANT_KEY sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-COMPTGT_FLT sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-DUMMY sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-MODIFIED sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-STD_COMP sy-vline
WA_/PLMI/S_RCA_COMP_BUFF_STR-ITEM_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.