ABAP Select data from SAP table /PLMB/S_SPC_BAS_STATUS_SP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_SPC_BAS_STATUS_SP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_SPC_BAS_STATUS_SP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_SPC_BAS_STATUS_SP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_SPC_BAS_STATUS_SP TYPE STANDARD TABLE OF /PLMB/S_SPC_BAS_STATUS_SP,
      WA_/PLMB/S_SPC_BAS_STATUS_SP TYPE /PLMB/S_SPC_BAS_STATUS_SP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_SPC_BAS_STATUS_SP> TYPE /PLMB/S_SPC_BAS_STATUS_SP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_SPC_BAS_STATUS_SP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_SPC_BAS_STATUS_SP
  INTO TABLE IT_/PLMB/S_SPC_BAS_STATUS_SP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_SPC_BAS_STATUS_SP
*  INTO TABLE @DATA(IT_/PLMB/S_SPC_BAS_STATUS_SP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_SPC_BAS_STATUS_SP INDEX 1 INTO DATA(WA_/PLMB/S_SPC_BAS_STATUS_SP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_SPC_BAS_STATUS_SP ASSIGNING </PLMB/S_SPC_BAS_STATUS_SP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_SPC_BAS_STATUS_SP>-MANDT = 1.
</PLMB/S_SPC_BAS_STATUS_SP>-VACLID = 1.
</PLMB/S_SPC_BAS_STATUS_SP>-VACLNAM = 1.
</PLMB/S_SPC_BAS_STATUS_SP>-RVLTYPE = 1.
</PLMB/S_SPC_BAS_STATUS_SP>-RVLID = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_SPC_BAS_STATUS_SP INTO WA_/PLMB/S_SPC_BAS_STATUS_SP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_SPC_BAS_STATUS_SP-RVLNAM, sy-vline,
WA_/PLMB/S_SPC_BAS_STATUS_SP-SUBSTAT_ON_SCREEN, sy-vline,
WA_/PLMB/S_SPC_BAS_STATUS_SP-STATUS_DESC, sy-vline,
WA_/PLMB/S_SPC_BAS_STATUS_SP-VALFR, sy-vline,
WA_/PLMB/S_SPC_BAS_STATUS_SP-VALTO, sy-vline,
WA_/PLMB/S_SPC_BAS_STATUS_SP-AENNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_SPC_BAS_STATUS_SP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_SPC_BAS_STATUS_SP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_SPC_BAS_STATUS_SP INTO WA_/PLMB/S_SPC_BAS_STATUS_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SCPST, internal->external for field SUBSTAT_ON_SCREEN CALL FUNCTION 'CONVERSION_EXIT_SCPST_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-SUBSTAT_ON_SCREEN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-SUBSTAT_ON_SCREEN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_BAS_STATUS_SP-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_BAS_STATUS_SP-OWNID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_SPC_BAS_STATUS_SP_STR,
MANDT TYPE STRING,
VACLID TYPE STRING,
VACLNAM TYPE STRING,
RVLTYPE TYPE STRING,
RVLID TYPE STRING,
RVLNAM TYPE STRING,
SUBSTAT_ON_SCREEN TYPE STRING,
STATUS_DESC TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
OTYPE TYPE STRING,
REALO TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
RECNROOT TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
LOGLOCKMOD TYPE STRING,
OBJNR TYPE STRING,
SUBSTAT TYPE STRING,
NAMEMST TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_SPC_BAS_STATUS_SP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-MANDT sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-VACLID sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-VACLNAM sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-RVLTYPE sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-RVLID sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-RVLNAM sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-SUBSTAT_ON_SCREEN sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-STATUS_DESC sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-VALFR sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-VALTO sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-AENNR sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-OTYPE sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-REALO sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-RECN sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-ACTN sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-RECNROOT sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-CRDAT sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-CRNAM sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-UPDDAT sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-UPDNAM sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-SRSID sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-OWNID sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-LOGLOCKMOD sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-OBJNR sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-SUBSTAT sy-vline
WA_/PLMB/S_SPC_BAS_STATUS_SP_STR-NAMEMST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.