ABAP Select data from SAP table /PLMB/S_RTG_COM_BO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_RTG_COM_BO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_RTG_COM_BO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_RTG_COM_BO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_RTG_COM_BO TYPE STANDARD TABLE OF /PLMB/S_RTG_COM_BO,
      WA_/PLMB/S_RTG_COM_BO TYPE /PLMB/S_RTG_COM_BO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_RTG_COM_BO> TYPE /PLMB/S_RTG_COM_BO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_RTG_COM_BO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_RTG_COM_BO
  INTO TABLE IT_/PLMB/S_RTG_COM_BO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_RTG_COM_BO
*  INTO TABLE @DATA(IT_/PLMB/S_RTG_COM_BO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_RTG_COM_BO INDEX 1 INTO DATA(WA_/PLMB/S_RTG_COM_BO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_RTG_COM_BO ASSIGNING </PLMB/S_RTG_COM_BO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_RTG_COM_BO>-PLNTY = 1.
</PLMB/S_RTG_COM_BO>-PLNNR = 1.
</PLMB/S_RTG_COM_BO>-PLNAL = 1.
</PLMB/S_RTG_COM_BO>-PLNFL = 1.
</PLMB/S_RTG_COM_BO>-PLNKN = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_RTG_COM_BO INTO WA_/PLMB/S_RTG_COM_BO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_RTG_COM_BO-ZAEHL, sy-vline,
WA_/PLMB/S_RTG_COM_BO-ZUONR, sy-vline,
WA_/PLMB/S_RTG_COM_BO-DATUV, sy-vline,
WA_/PLMB/S_RTG_COM_BO-TECHV, sy-vline,
WA_/PLMB/S_RTG_COM_BO-AENNR, sy-vline,
WA_/PLMB/S_RTG_COM_BO-LOEKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_RTG_COM_BO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_RTG_COM_BO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_RTG_COM_BO INTO WA_/PLMB/S_RTG_COM_BO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZUMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-ZUMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-ZUMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-IMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-IMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field GP_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-GP_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-GP_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field GP_UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-GP_UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-GP_UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AOBAR, internal->external for field AOBAR CALL FUNCTION 'CONVERSION_EXIT_AOBAR_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-AOBAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-AOBAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-ZEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-ZEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR_W CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-STLNR_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-STLNR_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL_W CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-STLAL_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-STLAL_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BOMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-BOMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-BOMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field IDNRK CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-IDNRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-IDNRK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ROMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-ROMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-ROMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR_AUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-AENNR_AUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-AENNR_AUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VPLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-VPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-VPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VPLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_COM_BO-VPLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_COM_BO-VPLAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_RTG_COM_BO_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
ZAEHL TYPE STRING,
ZUONR TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
AENNR TYPE STRING,
LOEKZ TYPE STRING,
PARKZ TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
STLKN TYPE STRING,
WERK_STL TYPE STRING,
ZUDIV TYPE STRING,
ZUMS1 TYPE STRING,
ZUMS2 TYPE STRING,
ZUMS3 TYPE STRING,
ZUMEI TYPE STRING,
IMENG TYPE STRING,
IMEIN TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
RGEKZ TYPE STRING,
STLST TYPE STRING,
STLWG TYPE STRING,
REFKN TYPE STRING,
GP_MATNR TYPE STRING,
GP_WERKS TYPE STRING,
GP_UVORN TYPE STRING,
GP_KRIT1 TYPE STRING,
GP_FREET TYPE STRING,
AOBAR TYPE STRING,
ZEINH TYPE STRING,
DAUER TYPE STRING,
DMENG TYPE STRING,
KNTTP TYPE STRING,
FLGEX TYPE STRING,
VORAB TYPE STRING,
STRECKE TYPE STRING,
STLTY_W TYPE STRING,
STLNR_W TYPE STRING,
STLAL_W TYPE STRING,
KANTE TYPE STRING,
LGORT TYPE STRING,
DISP TYPE STRING,
PRODFLOWID TYPE STRING,
BEIKZ TYPE STRING,
BOMAT TYPE STRING,
MAKTX TYPE STRING,
VBELN TYPE STRING,
VBPOS TYPE STRING,
PSPNR TYPE STRING,
WRKAN TYPE STRING,
DUMPS TYPE STRING,
POSTP TYPE STRING,
POSNR TYPE STRING,
IDENT_ITM TYPE STRING,
IDNRK TYPE STRING,
BOMOB TYPE STRING,
FMENG TYPE STRING,
SCHGT TYPE STRING,
KZKUP TYPE STRING,
KZWPF TYPE STRING,
KZCLB TYPE STRING,
KANTE_V TYPE STRING,
VORNR TYPE STRING,
ROANZ TYPE STRING,
ROMS1 TYPE STRING,
ROMS2 TYPE STRING,
ROMS3 TYPE STRING,
ROMEI TYPE STRING,
ROMEN TYPE STRING,
MEINS TYPE STRING,
RFORM TYPE STRING,
DATUB TYPE STRING,
AENNR_AUS TYPE STRING,
NLFZV TYPE STRING,
STPOZ TYPE STRING,
VPLTY TYPE STRING,
VPLNR TYPE STRING,
VPLAL TYPE STRING,
IDENT TYPE STRING,
IDENT_REF TYPE STRING,
HERKUNFT TYPE STRING,
STVKN_VERSN TYPE STRING,
DELETED_BY_PARAM_ECN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_RTG_COM_BO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PLNTY sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PLNNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PLNAL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PLNFL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PLNKN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZAEHL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUONR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DATUV sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-TECHV sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-AENNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-LOEKZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PARKZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLTY sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLAL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLKN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-WERK_STL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUDIV sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUMS1 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUMS2 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUMS3 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZUMEI sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IMENG sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IMEIN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ANDAT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ANNAM sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-AEDAT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-AENAM sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-RGEKZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLST sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLWG sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-REFKN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-GP_MATNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-GP_WERKS sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-GP_UVORN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-GP_KRIT1 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-GP_FREET sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-AOBAR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ZEINH sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DAUER sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DMENG sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KNTTP sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-FLGEX sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VORAB sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STRECKE sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLTY_W sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLNR_W sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STLAL_W sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KANTE sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-LGORT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DISP sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PRODFLOWID sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-BEIKZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-BOMAT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-MAKTX sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VBELN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VBPOS sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-PSPNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-WRKAN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DUMPS sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-POSTP sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-POSNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IDENT_ITM sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IDNRK sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-BOMOB sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-FMENG sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-SCHGT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KZKUP sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KZWPF sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KZCLB sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-KANTE_V sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VORNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROANZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROMS1 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROMS2 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROMS3 sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROMEI sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-ROMEN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-MEINS sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-RFORM sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DATUB sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-AENNR_AUS sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-NLFZV sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STPOZ sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VPLTY sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VPLNR sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-VPLAL sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IDENT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-IDENT_REF sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-HERKUNFT sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-STVKN_VERSN sy-vline
WA_/PLMB/S_RTG_COM_BO_STR-DELETED_BY_PARAM_ECN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.