ABAP Select data from SAP table /PLMB/S_GSS_R2B_SPLIT_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_GSS_R2B_SPLIT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_GSS_R2B_SPLIT_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_GSS_R2B_SPLIT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_GSS_R2B_SPLIT_DATA TYPE STANDARD TABLE OF /PLMB/S_GSS_R2B_SPLIT_DATA,
      WA_/PLMB/S_GSS_R2B_SPLIT_DATA TYPE /PLMB/S_GSS_R2B_SPLIT_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_GSS_R2B_SPLIT_DATA> TYPE /PLMB/S_GSS_R2B_SPLIT_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_GSS_R2B_SPLIT_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_GSS_R2B_SPLIT_DATA
  INTO TABLE IT_/PLMB/S_GSS_R2B_SPLIT_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_GSS_R2B_SPLIT_DATA
*  INTO TABLE @DATA(IT_/PLMB/S_GSS_R2B_SPLIT_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_GSS_R2B_SPLIT_DATA INDEX 1 INTO DATA(WA_/PLMB/S_GSS_R2B_SPLIT_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_GSS_R2B_SPLIT_DATA ASSIGNING </PLMB/S_GSS_R2B_SPLIT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_GSS_R2B_SPLIT_DATA>-SYNC_UNIT_GUID = 1.
</PLMB/S_GSS_R2B_SPLIT_DATA>-RCP_GUID = 1.
</PLMB/S_GSS_R2B_SPLIT_DATA>-RFO_GUID = 1.
</PLMB/S_GSS_R2B_SPLIT_DATA>-ITEM_GUID = 1.
</PLMB/S_GSS_R2B_SPLIT_DATA>-SRC_MATERIAL = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_GSS_R2B_SPLIT_DATA INTO WA_/PLMB/S_GSS_R2B_SPLIT_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_GSS_R2B_SPLIT_DATA-MATERIAL, sy-vline,
WA_/PLMB/S_GSS_R2B_SPLIT_DATA-PLANT, sy-vline,
WA_/PLMB/S_GSS_R2B_SPLIT_DATA-BOM_USAGE, sy-vline,
WA_/PLMB/S_GSS_R2B_SPLIT_DATA-ALTERNATIVE_BOM, sy-vline,
WA_/PLMB/S_GSS_R2B_SPLIT_DATA-TARGET_BOM_EXT, sy-vline,
WA_/PLMB/S_GSS_R2B_SPLIT_DATA-PARENT_NODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_GSS_R2B_SPLIT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_GSS_R2B_SPLIT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_GSS_R2B_SPLIT_DATA INTO WA_/PLMB/S_GSS_R2B_SPLIT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field SRC_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SRC_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SRC_MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALTERNATIVE_BOM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-ALTERNATIVE_BOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-ALTERNATIVE_BOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SCALE_TO_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SCALE_TO_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SCALE_TO_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SRC_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SRC_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-SRC_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RCPNZ, internal->external for field ST_ID CALL FUNCTION 'CONVERSION_EXIT_RCPNZ_OUTPUT' EXPORTING input = WA_/PLMB/S_GSS_R2B_SPLIT_DATA-ST_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_GSS_R2B_SPLIT_DATA-ST_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_GSS_R2B_SPLIT_DATA_STR,
SYNC_UNIT_GUID TYPE STRING,
RCP_GUID TYPE STRING,
RFO_GUID TYPE STRING,
ITEM_GUID TYPE STRING,
SRC_MATERIAL TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
BOM_USAGE TYPE STRING,
ALTERNATIVE_BOM TYPE STRING,
TARGET_BOM_EXT TYPE STRING,
PARENT_NODE TYPE STRING,
CHILD_NODE TYPE STRING,
EXT_KEY_Z_C TYPE STRING,
ICON_Z_C TYPE STRING,
IS_LEAF TYPE STRING,
SCALE_TO_QTY TYPE STRING,
SCALE_TO_UOM TYPE STRING,
SRC_QUANT TYPE STRING,
SRC_UOM TYPE STRING,
ST_ID TYPE STRING,
STAGE_DESC TYPE STRING,
MATERIAL_DESCR TYPE STRING,
BOM_USAGE_DESCR TYPE STRING,
BOM_EXISTS TYPE STRING,
VERS_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SYNC_UNIT_GUID sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-RCP_GUID sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-RFO_GUID sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-ITEM_GUID sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SRC_MATERIAL sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-MATERIAL sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-PLANT sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-BOM_USAGE sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-ALTERNATIVE_BOM sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-TARGET_BOM_EXT sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-PARENT_NODE sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-CHILD_NODE sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-EXT_KEY_Z_C sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-ICON_Z_C sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-IS_LEAF sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SCALE_TO_QTY sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SCALE_TO_UOM sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SRC_QUANT sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-SRC_UOM sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-ST_ID sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-STAGE_DESC sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-MATERIAL_DESCR sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-BOM_USAGE_DESCR sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-BOM_EXISTS sy-vline
WA_/PLMB/S_GSS_R2B_SPLIT_DATA_STR-VERS_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.