ABAP Select data from SAP table /PF1/STR_SN_ALV_OUTPUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PF1/STR_SN_ALV_OUTPUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PF1/STR_SN_ALV_OUTPUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PF1/STR_SN_ALV_OUTPUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PF1/STR_SN_ALV_OUTPUT TYPE STANDARD TABLE OF /PF1/STR_SN_ALV_OUTPUT,
      WA_/PF1/STR_SN_ALV_OUTPUT TYPE /PF1/STR_SN_ALV_OUTPUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PF1/STR_SN_ALV_OUTPUT> TYPE /PF1/STR_SN_ALV_OUTPUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PF1/STR_SN_ALV_OUTPUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PF1/STR_SN_ALV_OUTPUT
  INTO TABLE IT_/PF1/STR_SN_ALV_OUTPUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PF1/STR_SN_ALV_OUTPUT
*  INTO TABLE @DATA(IT_/PF1/STR_SN_ALV_OUTPUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PF1/STR_SN_ALV_OUTPUT INDEX 1 INTO DATA(WA_/PF1/STR_SN_ALV_OUTPUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PF1/STR_SN_ALV_OUTPUT ASSIGNING </PF1/STR_SN_ALV_OUTPUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PF1/STR_SN_ALV_OUTPUT>-STATUS_ICON = 1.
</PF1/STR_SN_ALV_OUTPUT>-CLEARING_AREA = 1.
</PF1/STR_SN_ALV_OUTPUT>-OBJECT_CATEGORY = 1.
</PF1/STR_SN_ALV_OUTPUT>-OBJ_DATE = 1.
</PF1/STR_SN_ALV_OUTPUT>-OBJ_NO = 1.
ENDLOOP.

LOOP AT IT_/PF1/STR_SN_ALV_OUTPUT INTO WA_/PF1/STR_SN_ALV_OUTPUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PF1/STR_SN_ALV_OUTPUT-OBJ_EXT, sy-vline,
WA_/PF1/STR_SN_ALV_OUTPUT-TECH_STAT, sy-vline,
WA_/PF1/STR_SN_ALV_OUTPUT-ERROR_CODE, sy-vline,
WA_/PF1/STR_SN_ALV_OUTPUT-FILENAME, sy-vline,
WA_/PF1/STR_SN_ALV_OUTPUT-OL_DATE, sy-vline,
WA_/PF1/STR_SN_ALV_OUTPUT-OL_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PF1/STR_SN_ALV_OUTPUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PF1/STR_SN_ALV_OUTPUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PF1/STR_SN_ALV_OUTPUT INTO WA_/PF1/STR_SN_ALV_OUTPUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PF1/STR_SN_ALV_OUTPUT_STR,
STATUS_ICON TYPE STRING,
CLEARING_AREA TYPE STRING,
OBJECT_CATEGORY TYPE STRING,
OBJ_DATE TYPE STRING,
OBJ_NO TYPE STRING,
OBJ_EXT TYPE STRING,
TECH_STAT TYPE STRING,
ERROR_CODE TYPE STRING,
FILENAME TYPE STRING,
OL_DATE TYPE STRING,
OL_NO TYPE STRING,
TEMPLATE_ID TYPE STRING,
TYPE_ID TYPE STRING,
OUTPUT_CONTROL TYPE STRING,
ITEM_INF TYPE STRING,
EOD_FLG TYPE STRING,
NOTIF_STATUS TYPE STRING,
ERROR_FLG TYPE STRING,
ERROR_DETAILS TYPE STRING,
CONVERTER_ID TYPE STRING,
IN_OUT_FORMAT TYPE STRING,
MEDIUM TYPE STRING,
CHANNEL TYPE STRING,
ERROR_ICON TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PF1/STR_SN_ALV_OUTPUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-STATUS_ICON sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-CLEARING_AREA sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OBJECT_CATEGORY sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OBJ_DATE sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OBJ_NO sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OBJ_EXT sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-TECH_STAT sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-ERROR_CODE sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-FILENAME sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OL_DATE sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OL_NO sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-TEMPLATE_ID sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-TYPE_ID sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-OUTPUT_CONTROL sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-ITEM_INF sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-EOD_FLG sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-NOTIF_STATUS sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-ERROR_FLG sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-ERROR_DETAILS sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-CONVERTER_ID sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-IN_OUT_FORMAT sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-MEDIUM sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-CHANNEL sy-vline
WA_/PF1/STR_SN_ALV_OUTPUT_STR-ERROR_ICON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.