ABAP Select data from SAP table /PF1/STR_PO_ITEM_DYNSEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PF1/STR_PO_ITEM_DYNSEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PF1/STR_PO_ITEM_DYNSEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PF1/STR_PO_ITEM_DYNSEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PF1/STR_PO_ITEM_DYNSEL TYPE STANDARD TABLE OF /PF1/STR_PO_ITEM_DYNSEL,
      WA_/PF1/STR_PO_ITEM_DYNSEL TYPE /PF1/STR_PO_ITEM_DYNSEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PF1/STR_PO_ITEM_DYNSEL> TYPE /PF1/STR_PO_ITEM_DYNSEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PF1/STR_PO_ITEM_DYNSEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PF1/STR_PO_ITEM_DYNSEL
  INTO TABLE IT_/PF1/STR_PO_ITEM_DYNSEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PF1/STR_PO_ITEM_DYNSEL
*  INTO TABLE @DATA(IT_/PF1/STR_PO_ITEM_DYNSEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PF1/STR_PO_ITEM_DYNSEL INDEX 1 INTO DATA(WA_/PF1/STR_PO_ITEM_DYNSEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PF1/STR_PO_ITEM_DYNSEL ASSIGNING </PF1/STR_PO_ITEM_DYNSEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PF1/STR_PO_ITEM_DYNSEL>-PI_DATE = 1.
</PF1/STR_PO_ITEM_DYNSEL>-PI_NO = 1.
</PF1/STR_PO_ITEM_DYNSEL>-TECH_STAT = 1.
</PF1/STR_PO_ITEM_DYNSEL>-PI_KIND = 1.
</PF1/STR_PO_ITEM_DYNSEL>-FLG_POSTED = 1.
ENDLOOP.

LOOP AT IT_/PF1/STR_PO_ITEM_DYNSEL INTO WA_/PF1/STR_PO_ITEM_DYNSEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PF1/STR_PO_ITEM_DYNSEL-FLG_RESERVED, sy-vline,
WA_/PF1/STR_PO_ITEM_DYNSEL-FLG_REVERSE_PI, sy-vline,
WA_/PF1/STR_PO_ITEM_DYNSEL-FLG_INTERNAL_USE, sy-vline,
WA_/PF1/STR_PO_ITEM_DYNSEL-REF_ROUTE, sy-vline,
WA_/PF1/STR_PO_ITEM_DYNSEL-REF_CLEARING, sy-vline,
WA_/PF1/STR_PO_ITEM_DYNSEL-REF_AM_AREA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PF1/STR_PO_ITEM_DYNSEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PF1/STR_PO_ITEM_DYNSEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PF1/STR_PO_ITEM_DYNSEL INTO WA_/PF1/STR_PO_ITEM_DYNSEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PF1/STR_PO_ITEM_DYNSEL_STR,
PI_DATE TYPE STRING,
PI_NO TYPE STRING,
TECH_STAT TYPE STRING,
PI_KIND TYPE STRING,
FLG_POSTED TYPE STRING,
FLG_RESERVED TYPE STRING,
FLG_REVERSE_PI TYPE STRING,
FLG_INTERNAL_USE TYPE STRING,
REF_ROUTE TYPE STRING,
REF_CLEARING TYPE STRING,
REF_AM_AREA TYPE STRING,
REF_PI_AM_AREA TYPE STRING,
REF_EXT_PO_ORIG TYPE STRING,
REF_EXT_PO TYPE STRING,
REF_COLL_DATE TYPE STRING,
REF_COLL_NO TYPE STRING,
REF_COLL_SEQ_NO TYPE STRING,
REF_PRENOTE_ID TYPE STRING,
COUNTRY TYPE STRING,
BANKKEY TYPE STRING,
BIC TYPE STRING,
IBAN TYPE STRING,
ACCT_NO TYPE STRING,
ACCT_CUR TYPE STRING,
HOLDER TYPE STRING,
CLRSYSIDCD TYPE STRING,
VAL_DATE TYPE STRING,
VAL_TIME TYPE STRING,
REF_VALUTA_ID TYPE STRING,
REF_RULESET_ID TYPE STRING,
VALUE_DATE_STAT TYPE STRING,
PI_POST_DATE TYPE STRING,
TR_CURR TYPE STRING,
TR_AMOUNT TYPE STRING,
TR_DEBCREDIND TYPE STRING,
TR_FEE TYPE STRING,
FEE_DEBCRED TYPE STRING,
A_CURR TYPE STRING,
A_AMOUNT TYPE STRING,
ORIGINAL_CURR TYPE STRING,
ORIGINAL_AMOUNT TYPE STRING,
A_FEE TYPE STRING,
EXCHNGRATE TYPE STRING,
FEE_INFO TYPE STRING,
NUM_ITEMS TYPE STRING,
TRANS_TYPE TYPE STRING,
PROCESS TYPE STRING,
PRIORITY TYPE STRING,
FLG_ENFORCE_POST TYPE STRING,
CHEQUE_NO TYPE STRING,
RETURN_CODE TYPE STRING,
WORK_BASKET_ID TYPE STRING,
PP_PRIORITY TYPE STRING,
CRUSR TYPE STRING,
CRDAT TYPE STRING,
CRTIM TYPE STRING,
CHUSR TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,
RLUSR TYPE STRING,
RLDAT TYPE STRING,
RLTIM TYPE STRING,
REF_CUST_SGM TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PF1/STR_PO_ITEM_DYNSEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PI_DATE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PI_NO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TECH_STAT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PI_KIND sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FLG_POSTED sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FLG_RESERVED sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FLG_REVERSE_PI sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FLG_INTERNAL_USE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_ROUTE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_CLEARING sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_AM_AREA sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_PI_AM_AREA sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_EXT_PO_ORIG sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_EXT_PO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_COLL_DATE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_COLL_NO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_COLL_SEQ_NO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_PRENOTE_ID sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-COUNTRY sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-BANKKEY sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-BIC sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-IBAN sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-ACCT_NO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-ACCT_CUR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-HOLDER sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CLRSYSIDCD sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-VAL_DATE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-VAL_TIME sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_VALUTA_ID sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_RULESET_ID sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-VALUE_DATE_STAT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PI_POST_DATE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TR_CURR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TR_AMOUNT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TR_DEBCREDIND sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TR_FEE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FEE_DEBCRED sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-A_CURR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-A_AMOUNT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-ORIGINAL_CURR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-ORIGINAL_AMOUNT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-A_FEE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-EXCHNGRATE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FEE_INFO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-NUM_ITEMS sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-TRANS_TYPE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PROCESS sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PRIORITY sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-FLG_ENFORCE_POST sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CHEQUE_NO sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-RETURN_CODE sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-WORK_BASKET_ID sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-PP_PRIORITY sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CRUSR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CRDAT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CRTIM sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CHUSR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CHDAT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-CHTIM sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-RLUSR sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-RLDAT sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-RLTIM sy-vline
WA_/PF1/STR_PO_ITEM_DYNSEL_STR-REF_CUST_SGM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.