ABAP Select data from SAP table /PF1/STR_BPE_CO_DFKKCOH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PF1/STR_BPE_CO_DFKKCOH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PF1/STR_BPE_CO_DFKKCOH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PF1/STR_BPE_CO_DFKKCOH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PF1/STR_BPE_CO_DFKKCOH TYPE STANDARD TABLE OF /PF1/STR_BPE_CO_DFKKCOH,
      WA_/PF1/STR_BPE_CO_DFKKCOH TYPE /PF1/STR_BPE_CO_DFKKCOH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PF1/STR_BPE_CO_DFKKCOH> TYPE /PF1/STR_BPE_CO_DFKKCOH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PF1/STR_BPE_CO_DFKKCOH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PF1/STR_BPE_CO_DFKKCOH
  INTO TABLE IT_/PF1/STR_BPE_CO_DFKKCOH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PF1/STR_BPE_CO_DFKKCOH
*  INTO TABLE @DATA(IT_/PF1/STR_BPE_CO_DFKKCOH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PF1/STR_BPE_CO_DFKKCOH INDEX 1 INTO DATA(WA_/PF1/STR_BPE_CO_DFKKCOH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PF1/STR_BPE_CO_DFKKCOH ASSIGNING </PF1/STR_BPE_CO_DFKKCOH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PF1/STR_BPE_CO_DFKKCOH>-MANDT = 1.
</PF1/STR_BPE_CO_DFKKCOH>-COTYP = 1.
</PF1/STR_BPE_CO_DFKKCOH>-COKEY = 1.
</PF1/STR_BPE_CO_DFKKCOH>-UNAME = 1.
</PF1/STR_BPE_CO_DFKKCOH>-CDATE = 1.
ENDLOOP.

LOOP AT IT_/PF1/STR_BPE_CO_DFKKCOH INTO WA_/PF1/STR_BPE_CO_DFKKCOH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PF1/STR_BPE_CO_DFKKCOH-CTIME, sy-vline,
WA_/PF1/STR_BPE_CO_DFKKCOH-VKONT, sy-vline,
WA_/PF1/STR_BPE_CO_DFKKCOH-DATA1, sy-vline,
WA_/PF1/STR_BPE_CO_DFKKCOH-DATA2, sy-vline,
WA_/PF1/STR_BPE_CO_DFKKCOH-DATA3, sy-vline,
WA_/PF1/STR_BPE_CO_DFKKCOH-ENTID4, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PF1/STR_BPE_CO_DFKKCOH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PF1/STR_BPE_CO_DFKKCOH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PF1/STR_BPE_CO_DFKKCOH INTO WA_/PF1/STR_BPE_CO_DFKKCOH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PF1/STR_BPE_CO_DFKKCOH-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PF1/STR_BPE_CO_DFKKCOH-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/PF1/STR_BPE_CO_DFKKCOH-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PF1/STR_BPE_CO_DFKKCOH-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PF1/STR_BPE_CO_DFKKCOH_STR,
MANDT TYPE STRING,
COTYP TYPE STRING,
COKEY TYPE STRING,
UNAME TYPE STRING,
CDATE TYPE STRING,
CTIME TYPE STRING,
VKONT TYPE STRING,
DATA1 TYPE STRING,
DATA2 TYPE STRING,
DATA3 TYPE STRING,
ENTID4 TYPE STRING,
DATA4 TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
XTEST TYPE STRING,
COPRI TYPE STRING,
COIDT TYPE STRING,
COITM TYPE STRING,
SPRAS TYPE STRING,
SALWA TYPE STRING,
SALBE TYPE STRING,
COPRI_LAUFI TYPE STRING,
CLEARING_AREA TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PF1/STR_BPE_CO_DFKKCOH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-MANDT sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COTYP sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COKEY sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-UNAME sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-CDATE sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-CTIME sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-VKONT sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-DATA1 sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-DATA2 sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-DATA3 sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-ENTID4 sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-DATA4 sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-LAUFD sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-LAUFI sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-XTEST sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COPRI sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COIDT sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COITM sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-SPRAS sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-SALWA sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-SALBE sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-COPRI_LAUFI sy-vline
WA_/PF1/STR_BPE_CO_DFKKCOH_STR-CLEARING_AREA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.