ABAP Select data from SAP table /OSP/S_REP_PARAMETER_DETAIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /OSP/S_REP_PARAMETER_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /OSP/S_REP_PARAMETER_DETAIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /OSP/S_REP_PARAMETER_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/OSP/S_REP_PARAMETER_DETAIL TYPE STANDARD TABLE OF /OSP/S_REP_PARAMETER_DETAIL,
      WA_/OSP/S_REP_PARAMETER_DETAIL TYPE /OSP/S_REP_PARAMETER_DETAIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </OSP/S_REP_PARAMETER_DETAIL> TYPE /OSP/S_REP_PARAMETER_DETAIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/OSP/S_REP_PARAMETER_DETAIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /OSP/S_REP_PARAMETER_DETAIL
  INTO TABLE IT_/OSP/S_REP_PARAMETER_DETAIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /OSP/S_REP_PARAMETER_DETAIL
*  INTO TABLE @DATA(IT_/OSP/S_REP_PARAMETER_DETAIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/OSP/S_REP_PARAMETER_DETAIL INDEX 1 INTO DATA(WA_/OSP/S_REP_PARAMETER_DETAIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/OSP/S_REP_PARAMETER_DETAIL ASSIGNING </OSP/S_REP_PARAMETER_DETAIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</OSP/S_REP_PARAMETER_DETAIL>-SELNAME = 1.
</OSP/S_REP_PARAMETER_DETAIL>-KIND = 1.
</OSP/S_REP_PARAMETER_DETAIL>-RADIO = 1.
</OSP/S_REP_PARAMETER_DETAIL>-RADIOGROUP = 1.
</OSP/S_REP_PARAMETER_DETAIL>-CHECKBOX = 1.
ENDLOOP.

LOOP AT IT_/OSP/S_REP_PARAMETER_DETAIL INTO WA_/OSP/S_REP_PARAMETER_DETAIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/OSP/S_REP_PARAMETER_DETAIL-NO_DISPLAY, sy-vline,
WA_/OSP/S_REP_PARAMETER_DETAIL-DFLT_SIGN, sy-vline,
WA_/OSP/S_REP_PARAMETER_DETAIL-DFLT_OPTN, sy-vline,
WA_/OSP/S_REP_PARAMETER_DETAIL-DFLT_LOW, sy-vline,
WA_/OSP/S_REP_PARAMETER_DETAIL-DFLT_HIGH, sy-vline,
WA_/OSP/S_REP_PARAMETER_DETAIL-REFFIELD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/OSP/S_REP_PARAMETER_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/OSP/S_REP_PARAMETER_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/OSP/S_REP_PARAMETER_DETAIL INTO WA_/OSP/S_REP_PARAMETER_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/OSP/S_REP_PARAMETER_DETAIL_STR,
SELNAME TYPE STRING,
KIND TYPE STRING,
RADIO TYPE STRING,
RADIOGROUP TYPE STRING,
CHECKBOX TYPE STRING,
NO_DISPLAY TYPE STRING,
DFLT_SIGN TYPE STRING,
DFLT_OPTN TYPE STRING,
DFLT_LOW TYPE STRING,
DFLT_HIGH TYPE STRING,
REFFIELD TYPE STRING,
TEXT TYPE STRING,
OBLIGATORY TYPE STRING,
NAME TYPE STRING,
NUMB TYPE STRING,
OLENGTH TYPE STRING,
TYPE TYPE STRING,
DTYP TYPE STRING,
DBFIELD TYPE STRING,
MISCELL TYPE STRING,
DB TYPE STRING,
APPENDAGE TYPE STRING,
OFFSET_ABAP TYPE STRING,
LENGTH TYPE STRING,
MATCHCODE TYPE STRING,
SPAGPA TYPE STRING,
LOWER_ABAP TYPE STRING,
NOSELSET TYPE STRING,
GROUP1 TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/OSP/S_REP_PARAMETER_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-SELNAME sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-KIND sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-RADIO sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-RADIOGROUP sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-CHECKBOX sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-NO_DISPLAY sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DFLT_SIGN sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DFLT_OPTN sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DFLT_LOW sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DFLT_HIGH sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-REFFIELD sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-TEXT sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-OBLIGATORY sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-NAME sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-NUMB sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-OLENGTH sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-TYPE sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DTYP sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DBFIELD sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-MISCELL sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-DB sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-APPENDAGE sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-OFFSET_ABAP sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-LENGTH sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-MATCHCODE sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-SPAGPA sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-LOWER_ABAP sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-NOSELSET sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-GROUP1 sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-FLAG1 sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-FLAG2 sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-FLAG3 sy-vline
WA_/OSP/S_REP_PARAMETER_DETAIL_STR-FLAG4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.