ABAP Select data from SAP table /NFM/NF_COMM_GEN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /NFM/NF_COMM_GEN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /NFM/NF_COMM_GEN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /NFM/NF_COMM_GEN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/NFM/NF_COMM_GEN TYPE STANDARD TABLE OF /NFM/NF_COMM_GEN,
      WA_/NFM/NF_COMM_GEN TYPE /NFM/NF_COMM_GEN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </NFM/NF_COMM_GEN> TYPE /NFM/NF_COMM_GEN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/NFM/NF_COMM_GEN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /NFM/NF_COMM_GEN
  INTO TABLE IT_/NFM/NF_COMM_GEN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /NFM/NF_COMM_GEN
*  INTO TABLE @DATA(IT_/NFM/NF_COMM_GEN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/NFM/NF_COMM_GEN INDEX 1 INTO DATA(WA_/NFM/NF_COMM_GEN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/NFM/NF_COMM_GEN ASSIGNING </NFM/NF_COMM_GEN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</NFM/NF_COMM_GEN>-WERKS = 1.
</NFM/NF_COMM_GEN>-BUKRS = 1.
</NFM/NF_COMM_GEN>-KWMNGL = 1.
</NFM/NF_COMM_GEN>-WADAT = 1.
</NFM/NF_COMM_GEN>-NES = 1.
ENDLOOP.

LOOP AT IT_/NFM/NF_COMM_GEN INTO WA_/NFM/NF_COMM_GEN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/NFM/NF_COMM_GEN-NFS, sy-vline,
WA_/NFM/NF_COMM_GEN-NDT, sy-vline,
WA_/NFM/NF_COMM_GEN-NKU, sy-vline,
WA_/NFM/NF_COMM_GEN-NKW, sy-vline,
WA_/NFM/NF_COMM_GEN-KDT, sy-vline,
WA_/NFM/NF_COMM_GEN-NMO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/NFM/NF_COMM_GEN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/NFM/NF_COMM_GEN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/NFM/NF_COMM_GEN INTO WA_/NFM/NF_COMM_GEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/NFM/NF_COMM_GEN-BME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/NFM/NF_COMM_GEN-BME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/NFM/NF_COMM_GEN-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/NFM/NF_COMM_GEN-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EIND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/NFM/NF_COMM_GEN-EIND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/NFM/NF_COMM_GEN-EIND.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/NFM/NF_COMM_GEN_STR,
WERKS TYPE STRING,
BUKRS TYPE STRING,
KWMNGL TYPE STRING,
WADAT TYPE STRING,
NES TYPE STRING,
NFS TYPE STRING,
NDT TYPE STRING,
NKU TYPE STRING,
NKW TYPE STRING,
KDT TYPE STRING,
NMO TYPE STRING,
EDS TYPE STRING,
STK TYPE STRING,
STB TYPE STRING,
VGW TYPE STRING,
BME TYPE STRING,
VGE TYPE STRING,
MEINS TYPE STRING,
EIND TYPE STRING,
EDM TYPE STRING,
EDB TYPE STRING,
TOL TYPE STRING,
KNL TYPE STRING,
BZU TYPE STRING,
BEK TYPE STRING,
BEM TYPE STRING,
BEB TYPE STRING,
KZN TYPE STRING,
BWR TYPE STRING,
BCU TYPE STRING,
BZS TYPE STRING,
KZS TYPE STRING,
HWAER TYPE STRING,
BKW TYPE STRING,
KK2 TYPE STRING,
KK3 TYPE STRING,
KGW1 TYPE STRING,
KGU1 TYPE STRING,
EING TYPE STRING,
BOESL TYPE STRING,
BMG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/NFM/NF_COMM_GEN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/NFM/NF_COMM_GEN_STR-WERKS sy-vline
WA_/NFM/NF_COMM_GEN_STR-BUKRS sy-vline
WA_/NFM/NF_COMM_GEN_STR-KWMNGL sy-vline
WA_/NFM/NF_COMM_GEN_STR-WADAT sy-vline
WA_/NFM/NF_COMM_GEN_STR-NES sy-vline
WA_/NFM/NF_COMM_GEN_STR-NFS sy-vline
WA_/NFM/NF_COMM_GEN_STR-NDT sy-vline
WA_/NFM/NF_COMM_GEN_STR-NKU sy-vline
WA_/NFM/NF_COMM_GEN_STR-NKW sy-vline
WA_/NFM/NF_COMM_GEN_STR-KDT sy-vline
WA_/NFM/NF_COMM_GEN_STR-NMO sy-vline
WA_/NFM/NF_COMM_GEN_STR-EDS sy-vline
WA_/NFM/NF_COMM_GEN_STR-STK sy-vline
WA_/NFM/NF_COMM_GEN_STR-STB sy-vline
WA_/NFM/NF_COMM_GEN_STR-VGW sy-vline
WA_/NFM/NF_COMM_GEN_STR-BME sy-vline
WA_/NFM/NF_COMM_GEN_STR-VGE sy-vline
WA_/NFM/NF_COMM_GEN_STR-MEINS sy-vline
WA_/NFM/NF_COMM_GEN_STR-EIND sy-vline
WA_/NFM/NF_COMM_GEN_STR-EDM sy-vline
WA_/NFM/NF_COMM_GEN_STR-EDB sy-vline
WA_/NFM/NF_COMM_GEN_STR-TOL sy-vline
WA_/NFM/NF_COMM_GEN_STR-KNL sy-vline
WA_/NFM/NF_COMM_GEN_STR-BZU sy-vline
WA_/NFM/NF_COMM_GEN_STR-BEK sy-vline
WA_/NFM/NF_COMM_GEN_STR-BEM sy-vline
WA_/NFM/NF_COMM_GEN_STR-BEB sy-vline
WA_/NFM/NF_COMM_GEN_STR-KZN sy-vline
WA_/NFM/NF_COMM_GEN_STR-BWR sy-vline
WA_/NFM/NF_COMM_GEN_STR-BCU sy-vline
WA_/NFM/NF_COMM_GEN_STR-BZS sy-vline
WA_/NFM/NF_COMM_GEN_STR-KZS sy-vline
WA_/NFM/NF_COMM_GEN_STR-HWAER sy-vline
WA_/NFM/NF_COMM_GEN_STR-BKW sy-vline
WA_/NFM/NF_COMM_GEN_STR-KK2 sy-vline
WA_/NFM/NF_COMM_GEN_STR-KK3 sy-vline
WA_/NFM/NF_COMM_GEN_STR-KGW1 sy-vline
WA_/NFM/NF_COMM_GEN_STR-KGU1 sy-vline
WA_/NFM/NF_COMM_GEN_STR-EING sy-vline
WA_/NFM/NF_COMM_GEN_STR-BOESL sy-vline
WA_/NFM/NF_COMM_GEN_STR-BMG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.