ABAP Select data from SAP table /MRSS/T_SGX_GANTT_RESOURCE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MRSS/T_SGX_GANTT_RESOURCE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MRSS/T_SGX_GANTT_RESOURCE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MRSS/T_SGX_GANTT_RESOURCE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MRSS/T_SGX_GANTT_RESOURCE TYPE STANDARD TABLE OF /MRSS/T_SGX_GANTT_RESOURCE,
      WA_/MRSS/T_SGX_GANTT_RESOURCE TYPE /MRSS/T_SGX_GANTT_RESOURCE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MRSS/T_SGX_GANTT_RESOURCE> TYPE /MRSS/T_SGX_GANTT_RESOURCE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MRSS/T_SGX_GANTT_RESOURCE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MRSS/T_SGX_GANTT_RESOURCE
  INTO TABLE IT_/MRSS/T_SGX_GANTT_RESOURCE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MRSS/T_SGX_GANTT_RESOURCE
*  INTO TABLE @DATA(IT_/MRSS/T_SGX_GANTT_RESOURCE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MRSS/T_SGX_GANTT_RESOURCE INDEX 1 INTO DATA(WA_/MRSS/T_SGX_GANTT_RESOURCE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MRSS/T_SGX_GANTT_RESOURCE ASSIGNING </MRSS/T_SGX_GANTT_RESOURCE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MRSS/T_SGX_GANTT_RESOURCE>-RESOURCE_ID = 1.
</MRSS/T_SGX_GANTT_RESOURCE>-ID = 1.
</MRSS/T_SGX_GANTT_RESOURCE>-TEXT = 1.
</MRSS/T_SGX_GANTT_RESOURCE>-TYPE = 1.
</MRSS/T_SGX_GANTT_RESOURCE>-REL = 1.
ENDLOOP.

LOOP AT IT_/MRSS/T_SGX_GANTT_RESOURCE INTO WA_/MRSS/T_SGX_GANTT_RESOURCE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MRSS/T_SGX_GANTT_RESOURCE-EDIT_MODE, sy-vline,
WA_/MRSS/T_SGX_GANTT_RESOURCE-PERNR, sy-vline,
WA_/MRSS/T_SGX_GANTT_RESOURCE-BEGDA, sy-vline,
WA_/MRSS/T_SGX_GANTT_RESOURCE-BEG_UZEIT, sy-vline,
WA_/MRSS/T_SGX_GANTT_RESOURCE-ENDDA, sy-vline,
WA_/MRSS/T_SGX_GANTT_RESOURCE-END_UZEIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MRSS/T_SGX_GANTT_RESOURCE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MRSS/T_SGX_GANTT_RESOURCE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MRSS/T_SGX_GANTT_RESOURCE INTO WA_/MRSS/T_SGX_GANTT_RESOURCE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MRSS/T_SGX_GANTT_RESOURCE_STR,
RESOURCE_ID TYPE STRING,
ID TYPE STRING,
TEXT TYPE STRING,
TYPE TYPE STRING,
REL TYPE STRING,
EDIT_MODE TYPE STRING,
PERNR TYPE STRING,
BEGDA TYPE STRING,
BEG_UZEIT TYPE STRING,
ENDDA TYPE STRING,
END_UZEIT TYPE STRING,
BEG_TIMESTAMP TYPE STRING,
END_TIMESTAMP TYPE STRING,
VISIBLE TYPE STRING,
CHANGED TYPE STRING,
NEW TYPE STRING,
AVAIL_ABSOLUTE TYPE STRING,
UTIL_RELATIVE TYPE STRING,
ORG_UNIT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
ISTAT TYPE STRING,
HISTO TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
REALO TYPE STRING,
CUSTOMER_FIELDS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MRSS/T_SGX_GANTT_RESOURCE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-RESOURCE_ID sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-ID sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-TEXT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-TYPE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-REL sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-EDIT_MODE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-PERNR sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-BEGDA sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-BEG_UZEIT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-ENDDA sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-END_UZEIT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-BEG_TIMESTAMP sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-END_TIMESTAMP sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-VISIBLE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-CHANGED sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-NEW sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-AVAIL_ABSOLUTE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-UTIL_RELATIVE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-ORG_UNIT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-PLVAR sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-OTYPE sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-OBJID sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-BEGDA sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-ENDDA sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-ISTAT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-HISTO sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-SHORT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-STEXT sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-REALO sy-vline
WA_/MRSS/T_SGX_GANTT_RESOURCE_STR-CUSTOMER_FIELDS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.