ABAP Select data from SAP table /MRSS/T_RSG_ORDER_PRT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MRSS/T_RSG_ORDER_PRT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MRSS/T_RSG_ORDER_PRT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MRSS/T_RSG_ORDER_PRT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MRSS/T_RSG_ORDER_PRT TYPE STANDARD TABLE OF /MRSS/T_RSG_ORDER_PRT,
      WA_/MRSS/T_RSG_ORDER_PRT TYPE /MRSS/T_RSG_ORDER_PRT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MRSS/T_RSG_ORDER_PRT> TYPE /MRSS/T_RSG_ORDER_PRT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MRSS/T_RSG_ORDER_PRT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MRSS/T_RSG_ORDER_PRT
  INTO TABLE IT_/MRSS/T_RSG_ORDER_PRT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MRSS/T_RSG_ORDER_PRT
*  INTO TABLE @DATA(IT_/MRSS/T_RSG_ORDER_PRT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MRSS/T_RSG_ORDER_PRT INDEX 1 INTO DATA(WA_/MRSS/T_RSG_ORDER_PRT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MRSS/T_RSG_ORDER_PRT ASSIGNING </MRSS/T_RSG_ORDER_PRT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MRSS/T_RSG_ORDER_PRT>-MANDT = 1.
</MRSS/T_RSG_ORDER_PRT>-AUFPL = 1.
</MRSS/T_RSG_ORDER_PRT>-PZLFH = 1.
</MRSS/T_RSG_ORDER_PRT>-LOEKZ = 1.
</MRSS/T_RSG_ORDER_PRT>-PARKZ = 1.
ENDLOOP.

LOOP AT IT_/MRSS/T_RSG_ORDER_PRT INTO WA_/MRSS/T_RSG_ORDER_PRT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MRSS/T_RSG_ORDER_PRT-DATUI, sy-vline,
WA_/MRSS/T_RSG_ORDER_PRT-USERI, sy-vline,
WA_/MRSS/T_RSG_ORDER_PRT-DATUC, sy-vline,
WA_/MRSS/T_RSG_ORDER_PRT-USERC, sy-vline,
WA_/MRSS/T_RSG_ORDER_PRT-OBJTY, sy-vline,
WA_/MRSS/T_RSG_ORDER_PRT-OBJID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MRSS/T_RSG_ORDER_PRT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MRSS/T_RSG_ORDER_PRT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MRSS/T_RSG_ORDER_PRT INTO WA_/MRSS/T_RSG_ORDER_PRT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR_KEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PLNNR_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PLNNR_KEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-DAUEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-DAUEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MGEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MGEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGSOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MGSOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MGSOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGISTEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MGISTEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MGISTEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGRSTEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MGRSTEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MGRSTEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGAUSEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MGAUSEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MGAUSEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EWEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EWEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWSOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EWSOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EWSOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWISTEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EWISTEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EWISTEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWRSTEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EWRSTEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EWRSTEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field FHMAR CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-FHMAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-FHMAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SFHNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-SFHNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-SFHNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-DOKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQWPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EQWPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EQWPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQPNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EQPNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EQPNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-BASEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-BASEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field ACTIVITY CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-ACTIVITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-ACTIVITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field PRT_CATEGORY CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_CATEGORY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_CATEGORY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MISCELLANEOUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MISCELLANEOUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MISCELLANEOUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCUMENT_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-DOCUMENT_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-DOCUMENT_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field START_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-START_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-START_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field END_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-END_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-END_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_MEASURE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASURE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASURE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_VALUE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_VALUE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_VALUE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_QUANTITY_SUM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_QUANTITY_SUM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_QUANTITY_SUM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_ACTUAL_USAGE_QUANTITY_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_ACTUAL_USAGE_QUANTITY_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_ACTUAL_USAGE_QUANTITY_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_REMAIN_USAGE_QUANTITY_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_REMAIN_USAGE_QUANTITY_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_REMAIN_USAGE_QUANTITY_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_VALUE_SUM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_VALUE_SUM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_USAGE_VALUE_SUM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_ACTUAL_USAGE_VALUE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_ACTUAL_USAGE_VALUE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_ACTUAL_USAGE_VALUE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_REMAIN_USAGE_VALUE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_REMAIN_USAGE_VALUE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_REMAIN_USAGE_VALUE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRT_MEASUREMENT_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASUREMENT_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASUREMENT_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_MEASUREMENT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASUREMENT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-PRT_MEASUREMENT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field MATERIAL_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field MATERIAL_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MRSS/T_RSG_ORDER_PRT-MATERIAL_VERSION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MRSS/T_RSG_ORDER_PRT_STR,
MANDT TYPE STRING,
AUFPL TYPE STRING,
PZLFH TYPE STRING,
LOEKZ TYPE STRING,
PARKZ TYPE STRING,
DATUI TYPE STRING,
USERI TYPE STRING,
DATUC TYPE STRING,
USERC TYPE STRING,
OBJTY TYPE STRING,
OBJID TYPE STRING,
PLNTY_KEY TYPE STRING,
PLNNR_KEY TYPE STRING,
PZLFH_KEY TYPE STRING,
ZAEHL_KEY TYPE STRING,
OBJCT TYPE STRING,
APLZL TYPE STRING,
PSNFH TYPE STRING,
OBJNR TYPE STRING,
STEUF TYPE STRING,
KZKBL TYPE STRING,
BZOFFB TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
BZOFFE TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
FSFHD TYPE STRING,
FSFHZ TYPE STRING,
FEFHD TYPE STRING,
FEFHZ TYPE STRING,
SSFHD TYPE STRING,
SSFHZ TYPE STRING,
SEFHD TYPE STRING,
SEFHZ TYPE STRING,
ISFHD TYPE STRING,
ISFHZ TYPE STRING,
IEFHD TYPE STRING,
IEFHZ TYPE STRING,
DAUFL TYPE STRING,
DAUEH TYPE STRING,
MGEINH TYPE STRING,
MGVGW TYPE STRING,
MGSOLEH TYPE STRING,
MGSOL TYPE STRING,
MGISTEH TYPE STRING,
MGIST TYPE STRING,
MGRSTEH TYPE STRING,
MGRST TYPE STRING,
MGAUSEH TYPE STRING,
MGAUS TYPE STRING,
MGFORM TYPE STRING,
EWEINH TYPE STRING,
EWVGW TYPE STRING,
EWSOLEH TYPE STRING,
EWSOL TYPE STRING,
EWISTEH TYPE STRING,
EWIST TYPE STRING,
EWRSTEH TYPE STRING,
EWRST TYPE STRING,
EWFORM TYPE STRING,
TXTSP TYPE STRING,
KTSCH TYPE STRING,
TXTZ1 TYPE STRING,
OBJTYPE TYPE STRING,
CH_PROC TYPE STRING,
AENNR TYPE STRING,
DAUSE TYPE STRING,
AUFNR TYPE STRING,
FHMAR TYPE STRING,
FHMNR TYPE STRING,
FHWRK TYPE STRING,
MATNR TYPE STRING,
SFHNR TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKVR TYPE STRING,
DOKTL TYPE STRING,
EQUNR TYPE STRING,
EQWPL TYPE STRING,
EQWTX TYPE STRING,
EQPNT TYPE STRING,
EQPTX TYPE STRING,
ATNAM TYPE STRING,
ATVOR TYPE STRING,
MSEHI TYPE STRING,
ATDIM TYPE STRING,
ANZDZ TYPE STRING,
FHKTX TYPE STRING,
BASEH TYPE STRING,
MEINS TYPE STRING,
FGRU1 TYPE STRING,
FGRU2 TYPE STRING,
STOWK TYPE STRING,
STORT TYPE STRING,
FSTTXT TYPE STRING,
CF_KZSVS TYPE STRING,
CF_KZSVE TYPE STRING,
CF_KZEVS TYPE STRING,
CF_KZEVE TYPE STRING,
STEUF_REF TYPE STRING,
KTSCH_REF TYPE STRING,
BZOFFB_REF TYPE STRING,
OFFSTB_REF TYPE STRING,
BZOFFE_REF TYPE STRING,
OFFSTE_REF TYPE STRING,
MGFORM_REF TYPE STRING,
EWFORM_REF TYPE STRING,
TXTKZ TYPE STRING,
INDBT TYPE STRING,
COMP_RES TYPE STRING,
VSNMR TYPE STRING,
ORGAUFPL TYPE STRING,
ORGPZLFH TYPE STRING,
ACTIVITY TYPE STRING,
ITEM_NO_OF_PRODUCTION_RESOURCE TYPE STRING,
PRT_PLANT TYPE STRING,
PRT_CATEGORY TYPE STRING,
PRT_NUMBER TYPE STRING,
MATERIAL TYPE STRING,
MISCELLANEOUS TYPE STRING,
DOCUMENT_TYPE TYPE STRING,
DOCUMENT_NUMBER TYPE STRING,
DOCUMENT_PART TYPE STRING,
DOCUMENT_VERSION TYPE STRING,
EQUIPMENT TYPE STRING,
STD_TEXT_KEY TYPE STRING,
DESCRIPTION TYPE STRING,
OBJECT_TYPE_CIM_RESOURCE TYPE STRING,
OBJECT_ID_CIM_RESOURCE TYPE STRING,
CTRL_KEY TYPE STRING,
CREATE_LOAD_RECS TYPE STRING,
START_REF_DATE TYPE STRING,
START_OFFSET TYPE STRING,
START_OFFSET_UNIT TYPE STRING,
START_OFFSET_UNIT_ISO TYPE STRING,
END_REF_DATE TYPE STRING,
END_OFFSET TYPE STRING,
END_OFFSET_UNIT TYPE STRING,
END_OFFSET_UNIT_ISO TYPE STRING,
PRT_MEASURE_UNIT TYPE STRING,
PRT_MEASURE_UNIT_ISO TYPE STRING,
STD_VALUE_FOR_PRT_QTY TYPE STRING,
FORMULA_TOT_QTY TYPE STRING,
STD_USAGE_VALUE_FOR_PRT TYPE STRING,
PRT_USAGE_VALUE_UNIT TYPE STRING,
PRT_USAGE_VALUE_UNIT_ISO TYPE STRING,
FORMULA_TOT_USAGE TYPE STRING,
PRT_USAGE_QUANTITY_SUM TYPE STRING,
PRT_USAGE_QUANTITY_SUM_UNIT TYPE STRING,
PRT_USAGE_QUANTITY_SUM_UN_ISO TYPE STRING,
PRT_ACTUAL_USAGE_QUANTITY TYPE STRING,
PRT_ACTUAL_USAGE_QUANTITY_UNIT TYPE STRING,
PRT_ACTUAL_USAGE_QUANTI_UN_ISO TYPE STRING,
PRT_REMAIN_USAGE_QUANTITY TYPE STRING,
PRT_REMAIN_USAGE_QUANTITY_UNIT TYPE STRING,
PRT_REMAIN_USAGE_QUANTI_UN_ISO TYPE STRING,
PRT_USAGE_VALUE_SUM TYPE STRING,
PRT_USAGE_VALUE_SUM_UNIT TYPE STRING,
PRT_USAGE_VALUE_SUM_UNIT_ISO TYPE STRING,
PRT_ACTUAL_USAGE_VALUE TYPE STRING,
PRT_ACTUAL_USAGE_VALUE_UNIT TYPE STRING,
PRT_ACTUAL_USAGE_VALUE_UN_ISO TYPE STRING,
PRT_REMAIN_USAGE_VALUE TYPE STRING,
PRT_REMAIN_USAGE_VALUE_UNIT TYPE STRING,
PRT_REMAIN_USAGE_VALUE_UN_ISO TYPE STRING,
PRT_MEASUREMENT_POINT TYPE STRING,
PRT_MEASUREMENT_UNIT TYPE STRING,
PRT_MEASUREMENT_UNIT_ISO TYPE STRING,
PRT_EARLIEST_START_DATE TYPE STRING,
PRT_EARLIEST_START_TIME TYPE STRING,
PRT_EARLIEST_FINISH_DATE TYPE STRING,
PRT_EARLIEST_FINISH_TIME TYPE STRING,
PRT_LATEST_START_DATE TYPE STRING,
PRT_LATEST_START_TIME TYPE STRING,
PRT_LATEST_FINISH_DATE TYPE STRING,
PRT_LATEST_FINISH_TIME TYPE STRING,
PRT_ACTUAL_START_DATE TYPE STRING,
PRT_ACTUAL_START_TIME TYPE STRING,
PRT_ACTUAL_FINISH_DATE TYPE STRING,
PRT_ACTUAL_FINISH_TIME TYPE STRING,
PRT_STATUS TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
OBJECT_NO TYPE STRING,
PRT_ITEM_COUNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MRSS/T_RSG_ORDER_PRT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MANDT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-AUFPL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PZLFH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-LOEKZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PARKZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DATUI sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-USERI sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DATUC sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-USERC sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJTY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJID sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PLNTY_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PLNNR_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PZLFH_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ZAEHL_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJCT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-APLZL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PSNFH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STEUF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-KZKBL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-BZOFFB sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OFFSTB sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EHOFFB sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-BZOFFE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OFFSTE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EHOFFE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FSFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FSFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FEFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FEFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-SSFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-SSFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-SEFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-SEFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ISFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ISFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-IEFHD sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-IEFHZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DAUFL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DAUEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGEINH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGVGW sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGSOLEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGSOL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGISTEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGIST sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGRSTEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGRST sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGAUSEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGAUS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGFORM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWEINH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWVGW sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWSOLEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWSOL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWISTEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWIST sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWRSTEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWRST sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWFORM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-TXTSP sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-KTSCH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-TXTZ1 sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJTYPE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CH_PROC sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-AENNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DAUSE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-AUFNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FHMAR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FHMNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FHWRK sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MATNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-SFHNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOKAR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOKNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOKVR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOKTL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQUNR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQWPL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQWTX sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQPNT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQPTX sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ATNAM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ATVOR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MSEHI sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ATDIM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ANZDZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FHKTX sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-BASEH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MEINS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FGRU1 sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FGRU2 sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STOWK sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STORT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FSTTXT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CF_KZSVS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CF_KZSVE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CF_KZEVS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CF_KZEVE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STEUF_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-KTSCH_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-BZOFFB_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OFFSTB_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-BZOFFE_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OFFSTE_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MGFORM_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EWFORM_REF sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-TXTKZ sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-INDBT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-COMP_RES sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-VSNMR sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ORGAUFPL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ORGPZLFH sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ACTIVITY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-ITEM_NO_OF_PRODUCTION_RESOURCE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_PLANT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_CATEGORY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_NUMBER sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MATERIAL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MISCELLANEOUS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOCUMENT_TYPE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOCUMENT_NUMBER sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOCUMENT_PART sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DOCUMENT_VERSION sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-EQUIPMENT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STD_TEXT_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-DESCRIPTION sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJECT_TYPE_CIM_RESOURCE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJECT_ID_CIM_RESOURCE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CTRL_KEY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-CREATE_LOAD_RECS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-START_REF_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-START_OFFSET sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-START_OFFSET_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-START_OFFSET_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-END_REF_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-END_OFFSET sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-END_OFFSET_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-END_OFFSET_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_MEASURE_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_MEASURE_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STD_VALUE_FOR_PRT_QTY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FORMULA_TOT_QTY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-STD_USAGE_VALUE_FOR_PRT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_VALUE_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_VALUE_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-FORMULA_TOT_USAGE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_QUANTITY_SUM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_QUANTITY_SUM_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_QUANTITY_SUM_UN_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_QUANTITY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_QUANTITY_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_QUANTI_UN_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_QUANTITY sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_QUANTITY_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_QUANTI_UN_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_VALUE_SUM sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_VALUE_SUM_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_USAGE_VALUE_SUM_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_VALUE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_VALUE_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_USAGE_VALUE_UN_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_VALUE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_VALUE_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_REMAIN_USAGE_VALUE_UN_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_MEASUREMENT_POINT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_MEASUREMENT_UNIT sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_MEASUREMENT_UNIT_ISO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_EARLIEST_START_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_EARLIEST_START_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_EARLIEST_FINISH_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_EARLIEST_FINISH_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_LATEST_START_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_LATEST_START_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_LATEST_FINISH_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_LATEST_FINISH_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_START_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_START_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_FINISH_DATE sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ACTUAL_FINISH_TIME sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_STATUS sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MATERIAL_EXTERNAL sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MATERIAL_GUID sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-MATERIAL_VERSION sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-OBJECT_NO sy-vline
WA_/MRSS/T_RSG_ORDER_PRT_STR-PRT_ITEM_COUNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.