ABAP Select data from SAP table /MRSS/T_R3_LOCK_ATTRIBUTES into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MRSS/T_R3_LOCK_ATTRIBUTES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MRSS/T_R3_LOCK_ATTRIBUTES. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MRSS/T_R3_LOCK_ATTRIBUTES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MRSS/T_R3_LOCK_ATTRIBUTES TYPE STANDARD TABLE OF /MRSS/T_R3_LOCK_ATTRIBUTES,
      WA_/MRSS/T_R3_LOCK_ATTRIBUTES TYPE /MRSS/T_R3_LOCK_ATTRIBUTES,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MRSS/T_R3_LOCK_ATTRIBUTES> TYPE /MRSS/T_R3_LOCK_ATTRIBUTES.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MRSS/T_R3_LOCK_ATTRIBUTES.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MRSS/T_R3_LOCK_ATTRIBUTES
  INTO TABLE IT_/MRSS/T_R3_LOCK_ATTRIBUTES.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MRSS/T_R3_LOCK_ATTRIBUTES
*  INTO TABLE @DATA(IT_/MRSS/T_R3_LOCK_ATTRIBUTES2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MRSS/T_R3_LOCK_ATTRIBUTES INDEX 1 INTO DATA(WA_/MRSS/T_R3_LOCK_ATTRIBUTES2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MRSS/T_R3_LOCK_ATTRIBUTES ASSIGNING </MRSS/T_R3_LOCK_ATTRIBUTES>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MRSS/T_R3_LOCK_ATTRIBUTES>-GUID = 1.
</MRSS/T_R3_LOCK_ATTRIBUTES>-LOCK_TYPE = 1.
</MRSS/T_R3_LOCK_ATTRIBUTES>-LOCK_SCOPE = 1.
</MRSS/T_R3_LOCK_ATTRIBUTES>-LOCK_ORIGIN_MRS = 1.
</MRSS/T_R3_LOCK_ATTRIBUTES>-LOCK_MANUALLY_SET = 1.
ENDLOOP.

LOOP AT IT_/MRSS/T_R3_LOCK_ATTRIBUTES INTO WA_/MRSS/T_R3_LOCK_ATTRIBUTES.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MRSS/T_R3_LOCK_ATTRIBUTES-MANUAL_LOCK_REMOVEABLE, sy-vline,
WA_/MRSS/T_R3_LOCK_ATTRIBUTES-LOCKED_BY, sy-vline,
WA_/MRSS/T_R3_LOCK_ATTRIBUTES-LOCK_NUMBER, sy-vline,
WA_/MRSS/T_R3_LOCK_ATTRIBUTES-LOCK_STEP_ID, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/MRSS/T_R3_LOCK_ATTRIBUTES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MRSS/T_R3_LOCK_ATTRIBUTES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MRSS/T_R3_LOCK_ATTRIBUTES INTO WA_/MRSS/T_R3_LOCK_ATTRIBUTES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MRSS/T_R3_LOCK_ATTRIBUTES_STR,
GUID TYPE STRING,
LOCK_TYPE TYPE STRING,
LOCK_SCOPE TYPE STRING,
LOCK_ORIGIN_MRS TYPE STRING,
LOCK_MANUALLY_SET TYPE STRING,
MANUAL_LOCK_REMOVEABLE TYPE STRING,
LOCKED_BY TYPE STRING,
LOCK_NUMBER TYPE STRING,
LOCK_STEP_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-GUID sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_TYPE sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_SCOPE sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_ORIGIN_MRS sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_MANUALLY_SET sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-MANUAL_LOCK_REMOVEABLE sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCKED_BY sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_NUMBER sy-vline
WA_/MRSS/T_R3_LOCK_ATTRIBUTES_STR-LOCK_STEP_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.