ABAP Select data from SAP table /J7L/BI_CA_TD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /J7L/BI_CA_TD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /J7L/BI_CA_TD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /J7L/BI_CA_TD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/J7L/BI_CA_TD TYPE STANDARD TABLE OF /J7L/BI_CA_TD,
      WA_/J7L/BI_CA_TD TYPE /J7L/BI_CA_TD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </J7L/BI_CA_TD> TYPE /J7L/BI_CA_TD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/J7L/BI_CA_TD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /J7L/BI_CA_TD
  INTO TABLE IT_/J7L/BI_CA_TD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /J7L/BI_CA_TD
*  INTO TABLE @DATA(IT_/J7L/BI_CA_TD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/J7L/BI_CA_TD INDEX 1 INTO DATA(WA_/J7L/BI_CA_TD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/J7L/BI_CA_TD ASSIGNING </J7L/BI_CA_TD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</J7L/BI_CA_TD>-UPDMOD = 1.
</J7L/BI_CA_TD>-MATNR = 1.
</J7L/BI_CA_TD>-VARIANTE = 1.
</J7L/BI_CA_TD>-BUKRS = 1.
</J7L/BI_CA_TD>-LAND1 = 1.
ENDLOOP.

LOOP AT IT_/J7L/BI_CA_TD INTO WA_/J7L/BI_CA_TD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/J7L/BI_CA_TD-ENTNR, sy-vline,
WA_/J7L/BI_CA_TD-DATBI, sy-vline,
WA_/J7L/BI_CA_TD-DATAB, sy-vline,
WA_/J7L/BI_CA_TD-POSAR, sy-vline,
WA_/J7L/BI_CA_TD-POSAR2, sy-vline,
WA_/J7L/BI_CA_TD-HRKFTSD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/J7L/BI_CA_TD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/J7L/BI_CA_TD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/J7L/BI_CA_TD INTO WA_/J7L/BI_CA_TD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-ENTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-ENTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-MBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-MBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field KMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-KMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-KMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field VRPNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/J7L/BI_CA_TD-VRPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/J7L/BI_CA_TD-VRPNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/J7L/BI_CA_TD_STR,
UPDMOD TYPE STRING,
MATNR TYPE STRING,
VARIANTE TYPE STRING,
BUKRS TYPE STRING,
LAND1 TYPE STRING,
ENTNR TYPE STRING,
DATBI TYPE STRING,
DATAB TYPE STRING,
POSAR TYPE STRING,
POSAR2 TYPE STRING,
HRKFTSD TYPE STRING,
HRKFTMM TYPE STRING,
HRKFTUT TYPE STRING,
VBELN TYPE STRING,
MBLNR TYPE STRING,
BLART TYPE STRING,
ENTNA TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
WERKS TYPE STRING,
LLAND TYPE STRING,
KUMRK TYPE STRING,
KUNNR TYPE STRING,
PARVW TYPE STRING,
EKORG TYPE STRING,
LIMRK TYPE STRING,
LIFNR TYPE STRING,
MTART TYPE STRING,
PRDHA TYPE STRING,
GRUPPE TYPE STRING,
MATKL TYPE STRING,
MBRSH TYPE STRING,
GSBER TYPE STRING,
PGAAWR TYPE STRING,
NETWR TYPE STRING,
WAERK TYPE STRING,
FKIMG TYPE STRING,
VRKME TYPE STRING,
FKIMP TYPE STRING,
KOKEY TYPE STRING,
KZPRAD TYPE STRING,
SPLIT TYPE STRING,
VFLKL TYPE STRING,
VFLST TYPE STRING,
KMEIN TYPE STRING,
STOFE TYPE STRING,
STGEW TYPE STRING,
GEWEI TYPE STRING,
VRPNR TYPE STRING,
VVARIANTE TYPE STRING,
VPEBENE TYPE STRING,
VPARTS TYPE STRING,
VPARTG TYPE STRING,
VRPKT TYPE STRING,
INFOK TYPE STRING,
FUELLG TYPE STRING,
HDLST TYPE STRING,
AEDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/J7L/BI_CA_TD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/J7L/BI_CA_TD_STR-UPDMOD sy-vline
WA_/J7L/BI_CA_TD_STR-MATNR sy-vline
WA_/J7L/BI_CA_TD_STR-VARIANTE sy-vline
WA_/J7L/BI_CA_TD_STR-BUKRS sy-vline
WA_/J7L/BI_CA_TD_STR-LAND1 sy-vline
WA_/J7L/BI_CA_TD_STR-ENTNR sy-vline
WA_/J7L/BI_CA_TD_STR-DATBI sy-vline
WA_/J7L/BI_CA_TD_STR-DATAB sy-vline
WA_/J7L/BI_CA_TD_STR-POSAR sy-vline
WA_/J7L/BI_CA_TD_STR-POSAR2 sy-vline
WA_/J7L/BI_CA_TD_STR-HRKFTSD sy-vline
WA_/J7L/BI_CA_TD_STR-HRKFTMM sy-vline
WA_/J7L/BI_CA_TD_STR-HRKFTUT sy-vline
WA_/J7L/BI_CA_TD_STR-VBELN sy-vline
WA_/J7L/BI_CA_TD_STR-MBLNR sy-vline
WA_/J7L/BI_CA_TD_STR-BLART sy-vline
WA_/J7L/BI_CA_TD_STR-ENTNA sy-vline
WA_/J7L/BI_CA_TD_STR-VKORG sy-vline
WA_/J7L/BI_CA_TD_STR-VTWEG sy-vline
WA_/J7L/BI_CA_TD_STR-SPART sy-vline
WA_/J7L/BI_CA_TD_STR-WERKS sy-vline
WA_/J7L/BI_CA_TD_STR-LLAND sy-vline
WA_/J7L/BI_CA_TD_STR-KUMRK sy-vline
WA_/J7L/BI_CA_TD_STR-KUNNR sy-vline
WA_/J7L/BI_CA_TD_STR-PARVW sy-vline
WA_/J7L/BI_CA_TD_STR-EKORG sy-vline
WA_/J7L/BI_CA_TD_STR-LIMRK sy-vline
WA_/J7L/BI_CA_TD_STR-LIFNR sy-vline
WA_/J7L/BI_CA_TD_STR-MTART sy-vline
WA_/J7L/BI_CA_TD_STR-PRDHA sy-vline
WA_/J7L/BI_CA_TD_STR-GRUPPE sy-vline
WA_/J7L/BI_CA_TD_STR-MATKL sy-vline
WA_/J7L/BI_CA_TD_STR-MBRSH sy-vline
WA_/J7L/BI_CA_TD_STR-GSBER sy-vline
WA_/J7L/BI_CA_TD_STR-PGAAWR sy-vline
WA_/J7L/BI_CA_TD_STR-NETWR sy-vline
WA_/J7L/BI_CA_TD_STR-WAERK sy-vline
WA_/J7L/BI_CA_TD_STR-FKIMG sy-vline
WA_/J7L/BI_CA_TD_STR-VRKME sy-vline
WA_/J7L/BI_CA_TD_STR-FKIMP sy-vline
WA_/J7L/BI_CA_TD_STR-KOKEY sy-vline
WA_/J7L/BI_CA_TD_STR-KZPRAD sy-vline
WA_/J7L/BI_CA_TD_STR-SPLIT sy-vline
WA_/J7L/BI_CA_TD_STR-VFLKL sy-vline
WA_/J7L/BI_CA_TD_STR-VFLST sy-vline
WA_/J7L/BI_CA_TD_STR-KMEIN sy-vline
WA_/J7L/BI_CA_TD_STR-STOFE sy-vline
WA_/J7L/BI_CA_TD_STR-STGEW sy-vline
WA_/J7L/BI_CA_TD_STR-GEWEI sy-vline
WA_/J7L/BI_CA_TD_STR-VRPNR sy-vline
WA_/J7L/BI_CA_TD_STR-VVARIANTE sy-vline
WA_/J7L/BI_CA_TD_STR-VPEBENE sy-vline
WA_/J7L/BI_CA_TD_STR-VPARTS sy-vline
WA_/J7L/BI_CA_TD_STR-VPARTG sy-vline
WA_/J7L/BI_CA_TD_STR-VRPKT sy-vline
WA_/J7L/BI_CA_TD_STR-INFOK sy-vline
WA_/J7L/BI_CA_TD_STR-FUELLG sy-vline
WA_/J7L/BI_CA_TD_STR-HDLST sy-vline
WA_/J7L/BI_CA_TD_STR-AEDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.