ABAP Select data from SAP table /ISIDEX/EIDENT_OBJECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISIDEX/EIDENT_OBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISIDEX/EIDENT_OBJECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISIDEX/EIDENT_OBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISIDEX/EIDENT_OBJECT TYPE STANDARD TABLE OF /ISIDEX/EIDENT_OBJECT,
      WA_/ISIDEX/EIDENT_OBJECT TYPE /ISIDEX/EIDENT_OBJECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISIDEX/EIDENT_OBJECT> TYPE /ISIDEX/EIDENT_OBJECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISIDEX/EIDENT_OBJECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISIDEX/EIDENT_OBJECT
  INTO TABLE IT_/ISIDEX/EIDENT_OBJECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISIDEX/EIDENT_OBJECT
*  INTO TABLE @DATA(IT_/ISIDEX/EIDENT_OBJECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISIDEX/EIDENT_OBJECT INDEX 1 INTO DATA(WA_/ISIDEX/EIDENT_OBJECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISIDEX/EIDENT_OBJECT ASSIGNING </ISIDEX/EIDENT_OBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISIDEX/EIDENT_OBJECT>-CONTROL = 1.
</ISIDEX/EIDENT_OBJECT>-GRID_CONTROL = 1.
</ISIDEX/EIDENT_OBJECT>-GRID_CONTAINER = 1.
</ISIDEX/EIDENT_OBJECT>-GRID = 1.
</ISIDEX/EIDENT_OBJECT>-REFRESH_GRID = 1.
ENDLOOP.

LOOP AT IT_/ISIDEX/EIDENT_OBJECT INTO WA_/ISIDEX/EIDENT_OBJECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISIDEX/EIDENT_OBJECT-LAST_CONTAINER, sy-vline,
WA_/ISIDEX/EIDENT_OBJECT-GRID_CONTROL_SD, sy-vline,
WA_/ISIDEX/EIDENT_OBJECT-GRID_CONTAINER, sy-vline,
WA_/ISIDEX/EIDENT_OBJECT-GRID, sy-vline,
WA_/ISIDEX/EIDENT_OBJECT-REFRESH_GRID, sy-vline,
WA_/ISIDEX/EIDENT_OBJECT-LAST_CONTAINER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISIDEX/EIDENT_OBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISIDEX/EIDENT_OBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISIDEX/EIDENT_OBJECT INTO WA_/ISIDEX/EIDENT_OBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GERNR, internal->external for field METERNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_/ISIDEX/EIDENT_OBJECT-METERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISIDEX/EIDENT_OBJECT-METERNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BU_PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISIDEX/EIDENT_OBJECT-BU_PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISIDEX/EIDENT_OBJECT-BU_PARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HOTSPOT_BUPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISIDEX/EIDENT_OBJECT-HOTSPOT_BUPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISIDEX/EIDENT_OBJECT-HOTSPOT_BUPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HOTSPOT_CONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISIDEX/EIDENT_OBJECT-HOTSPOT_CONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISIDEX/EIDENT_OBJECT-HOTSPOT_CONTRACT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISIDEX/EIDENT_OBJECT_STR,
CONTROL TYPE STRING,
GRID_CONTROL TYPE STRING,
GRID_CONTAINER TYPE STRING,
GRID TYPE STRING,
REFRESH_GRID TYPE STRING,
LAST_CONTAINER TYPE STRING,
GRID_CONTROL_SD TYPE STRING,
GRID_CONTAINER TYPE STRING,
GRID TYPE STRING,
REFRESH_GRID TYPE STRING,
LAST_CONTAINER TYPE STRING,
WMODE TYPE STRING,
OPEN_WMODE TYPE STRING,
UPD_ONLINE TYPE STRING,
NO_DIALOG TYPE STRING,
NUM_RANGE TYPE STRING,
NO_CHANGE TYPE STRING,
NO_OTHER TYPE STRING,
NO_EVENT TYPE STRING,
NO_STATISTIC TYPE STRING,
NO_CHANGE_DOC TYPE STRING,
CALLED_BY_IDOC TYPE STRING,
PROPRICE TYPE STRING,
INPERR TYPE STRING,
ENQ_DONE TYPE STRING,
CURFIELD TYPE STRING,
CURLINE TYPE STRING,
CURDYNNR TYPE STRING,
SETCURFIELD TYPE STRING,
SETCURLINE TYPE STRING,
SETCURDYNNR TYPE STRING,
TEXT_CHANGED TYPE STRING,
EXTINTKZ TYPE STRING,
EXIT_TYPE TYPE STRING,
FULLSCREEN TYPE STRING,
SAVE_OKCODE TYPE STRING,
TEILOBJ TYPE STRING,
S_FUBA TYPE STRING,
INPUT_FIELD_OFF TYPE STRING,
NOFULLSCREEN TYPE STRING,
DB_UPDATE TYPE STRING,
CHANGEFLAG TYPE STRING,
WA_ADR_DONE TYPE STRING,
IDENTSTATUS TYPE STRING,
SEARCHD_CHANGED TYPE STRING,
PROCVAR_CHANGED TYPE STRING,
ACTION_NEW_SEARCH TYPE STRING,
DIALOG_TITEL TYPE STRING,
BADI_OBJ TYPE STRING,
BADI_ACTIVE TYPE STRING,
CUST_FUGR_NAME TYPE STRING,
CUST_DYN_NR TYPE STRING,
SEL_OBJ_ERRORFIELD TYPE STRING,
OBJ_PUBLIC TYPE STRING,
SUB_REPID TYPE STRING,
SUB_DYNNR TYPE STRING,
SUBSL_REPID TYPE STRING,
SUBSL_DYNNR TYPE STRING,
SCREEN TYPE STRING,
ALV_GRID TYPE STRING,
ALV_GRID_SD TYPE STRING,
SEARCH_DATA TYPE STRING,
KEYDATE TYPE STRING,
EXT_UI TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
STREET TYPE STRING,
HOUSENR TYPE STRING,
HOUSENREXT TYPE STRING,
POSTCODE TYPE STRING,
CITY TYPE STRING,
FLOOR TYPE STRING,
ROOMNUMBER TYPE STRING,
STREETBU_ TYPE STRING,
HOUSENRBU_ TYPE STRING,
HOUSENREXTBU_ TYPE STRING,
POSTCODEBU_ TYPE STRING,
CITYBU_ TYPE STRING,
FLOORBU_ TYPE STRING,
ROOMNUMBERBU_ TYPE STRING,
METERNR TYPE STRING,
BU_PARTNER TYPE STRING,
IDREFNR TYPE STRING,
TRANSREASON TYPE STRING,
SERVICEID TYPE STRING,
SWTMDCAT TYPE STRING,
SPARTYP TYPE STRING,
PROCVARID TYPE STRING,
PROCVARTXT TYPE STRING,
SERVPROV_TXT TYPE STRING,
DEREGPROC TYPE STRING,
IDENT_HITS TYPE STRING,
IDENTSTATUS TYPE STRING,
IDENT_IDENT_HITS TYPE STRING,
HOTSPOT_BUPART TYPE STRING,
HOTSPOT_INT_UI TYPE STRING,
HOTSPOT_CONTRACT TYPE STRING,
OBJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISIDEX/EIDENT_OBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CONTROL sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID_CONTROL sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID_CONTAINER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-REFRESH_GRID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-LAST_CONTAINER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID_CONTROL_SD sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID_CONTAINER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-GRID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-REFRESH_GRID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-LAST_CONTAINER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-WMODE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-OPEN_WMODE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-UPD_ONLINE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_DIALOG sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NUM_RANGE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_CHANGE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_OTHER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_EVENT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_STATISTIC sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NO_CHANGE_DOC sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CALLED_BY_IDOC sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-PROPRICE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-INPERR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ENQ_DONE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CURFIELD sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CURLINE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CURDYNNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SETCURFIELD sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SETCURLINE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SETCURDYNNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-TEXT_CHANGED sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-EXTINTKZ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-EXIT_TYPE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-FULLSCREEN sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SAVE_OKCODE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-TEILOBJ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-S_FUBA sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-INPUT_FIELD_OFF sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NOFULLSCREEN sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-DB_UPDATE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CHANGEFLAG sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-WA_ADR_DONE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-IDENTSTATUS sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SEARCHD_CHANGED sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-PROCVAR_CHANGED sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ACTION_NEW_SEARCH sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-DIALOG_TITEL sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-BADI_OBJ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-BADI_ACTIVE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CUST_FUGR_NAME sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CUST_DYN_NR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SEL_OBJ_ERRORFIELD sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-OBJ_PUBLIC sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SUB_REPID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SUB_DYNNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SUBSL_REPID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SUBSL_DYNNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SCREEN sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ALV_GRID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ALV_GRID_SD sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SEARCH_DATA sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-KEYDATE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-EXT_UI sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NAME1 sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-NAME2 sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-STREET sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOUSENR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOUSENREXT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-POSTCODE sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CITY sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-FLOOR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ROOMNUMBER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-STREETBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOUSENRBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOUSENREXTBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-POSTCODEBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-CITYBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-FLOORBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-ROOMNUMBERBU_ sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-METERNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-BU_PARTNER sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-IDREFNR sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-TRANSREASON sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SERVICEID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SWTMDCAT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SPARTYP sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-PROCVARID sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-PROCVARTXT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-SERVPROV_TXT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-DEREGPROC sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-IDENT_HITS sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-IDENTSTATUS sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-IDENT_IDENT_HITS sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOTSPOT_BUPART sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOTSPOT_INT_UI sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-HOTSPOT_CONTRACT sy-vline
WA_/ISIDEX/EIDENT_OBJECT_STR-OBJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.