ABAP Select data from SAP table /ISDFPS/WOUPS_CAUFV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/WOUPS_CAUFV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/WOUPS_CAUFV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/WOUPS_CAUFV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/WOUPS_CAUFV TYPE STANDARD TABLE OF /ISDFPS/WOUPS_CAUFV,
      WA_/ISDFPS/WOUPS_CAUFV TYPE /ISDFPS/WOUPS_CAUFV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/WOUPS_CAUFV> TYPE /ISDFPS/WOUPS_CAUFV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/WOUPS_CAUFV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/WOUPS_CAUFV
  INTO TABLE IT_/ISDFPS/WOUPS_CAUFV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/WOUPS_CAUFV
*  INTO TABLE @DATA(IT_/ISDFPS/WOUPS_CAUFV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/WOUPS_CAUFV INDEX 1 INTO DATA(WA_/ISDFPS/WOUPS_CAUFV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/WOUPS_CAUFV ASSIGNING </ISDFPS/WOUPS_CAUFV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/WOUPS_CAUFV>-AKKNZ = 1.
</ISDFPS/WOUPS_CAUFV>-PLNTY = 1.
</ISDFPS/WOUPS_CAUFV>-PLNNR = 1.
</ISDFPS/WOUPS_CAUFV>-PLNAL = 1.
</ISDFPS/WOUPS_CAUFV>-MAUFNR = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/WOUPS_CAUFV INTO WA_/ISDFPS/WOUPS_CAUFV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/WOUPS_CAUFV-LEAD_AUFNR, sy-vline,
WA_/ISDFPS/WOUPS_CAUFV-WARPL, sy-vline,
WA_/ISDFPS/WOUPS_CAUFV-ABNUM, sy-vline,
WA_/ISDFPS/WOUPS_CAUFV-WAPOS, sy-vline,
WA_/ISDFPS/WOUPS_CAUFV-MHIO_ADDATE, sy-vline,
WA_/ISDFPS/WOUPS_CAUFV-MHIO_ADTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/WOUPS_CAUFV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/WOUPS_CAUFV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/WOUPS_CAUFV INTO WA_/ISDFPS/WOUPS_CAUFV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-MAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-MAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEAD_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-LEAD_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-LEAD_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WARPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-WARPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-WARPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/WOUPS_CAUFV-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/WOUPS_CAUFV-WAPOS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/WOUPS_CAUFV_STR,
AKKNZ TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
MAUFNR TYPE STRING,
LEAD_AUFNR TYPE STRING,
WARPL TYPE STRING,
ABNUM TYPE STRING,
WAPOS TYPE STRING,
MHIO_ADDATE TYPE STRING,
MHIO_ADTIME TYPE STRING,
USERMODE TYPE STRING,
FTRMI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/WOUPS_CAUFV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-AKKNZ sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-PLNTY sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-PLNNR sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-PLNAL sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-MAUFNR sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-LEAD_AUFNR sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-WARPL sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-ABNUM sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-WAPOS sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-MHIO_ADDATE sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-MHIO_ADTIME sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-USERMODE sy-vline
WA_/ISDFPS/WOUPS_CAUFV_STR-FTRMI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.