ABAP Select data from SAP table /ISDFPS/S_BI_PA0800 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/S_BI_PA0800 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/S_BI_PA0800. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/S_BI_PA0800 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/S_BI_PA0800 TYPE STANDARD TABLE OF /ISDFPS/S_BI_PA0800,
      WA_/ISDFPS/S_BI_PA0800 TYPE /ISDFPS/S_BI_PA0800,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/S_BI_PA0800> TYPE /ISDFPS/S_BI_PA0800.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/S_BI_PA0800.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/S_BI_PA0800
  INTO TABLE IT_/ISDFPS/S_BI_PA0800.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/S_BI_PA0800
*  INTO TABLE @DATA(IT_/ISDFPS/S_BI_PA08002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/S_BI_PA0800 INDEX 1 INTO DATA(WA_/ISDFPS/S_BI_PA08002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/S_BI_PA0800 ASSIGNING </ISDFPS/S_BI_PA0800>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/S_BI_PA0800>-MANDT = 1.
</ISDFPS/S_BI_PA0800>-PERNR = 1.
</ISDFPS/S_BI_PA0800>-SUBTY = 1.
</ISDFPS/S_BI_PA0800>-OBJPS = 1.
</ISDFPS/S_BI_PA0800>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/S_BI_PA0800 INTO WA_/ISDFPS/S_BI_PA0800.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/S_BI_PA0800-ENDDA, sy-vline,
WA_/ISDFPS/S_BI_PA0800-BEGDA, sy-vline,
WA_/ISDFPS/S_BI_PA0800-SEQNR, sy-vline,
WA_/ISDFPS/S_BI_PA0800-AEDTM, sy-vline,
WA_/ISDFPS/S_BI_PA0800-UNAME, sy-vline,
WA_/ISDFPS/S_BI_PA0800-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/S_BI_PA0800 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/S_BI_PA0800 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/S_BI_PA0800 INTO WA_/ISDFPS/S_BI_PA0800. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIAL CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-SERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-SERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field IMATDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-IMATDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-IMATDOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RMATDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-RMATDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-RMATDOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field IVBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-IVBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-IVBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field MAT_WBSELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-MAT_WBSELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-MAT_WBSELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV_HU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-EXIDV_HU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-EXIDV_HU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRMDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-SRMDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-SRMDOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-COSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MPO_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BI_PA0800-MPO_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BI_PA0800-MPO_MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/S_BI_PA0800_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
MATNR TYPE STRING,
SERIAL TYPE STRING,
MATTY TYPE STRING,
QUGIR TYPE STRING,
STATUS TYPE STRING,
STORAGE TYPE STRING,
UTYPE TYPE STRING,
IMATDOC TYPE STRING,
IMATPOS TYPE STRING,
RMATDOC TYPE STRING,
RMATPOS TYPE STRING,
ORGEH_ID TYPE STRING,
MPO_GUID TYPE STRING,
MC_GUID TYPE STRING,
EPA_GUID TYPE STRING,
MCCODE TYPE STRING,
MEINS TYPE STRING,
IVBELN TYPE STRING,
IPOSNR TYPE STRING,
ORIG_ENDDA TYPE STRING,
LAST_ENDDA_UPD TYPE STRING,
ENDDA_ADP_COUNT TYPE STRING,
ORIG_PERNR TYPE STRING,
LAST_PERNR TYPE STRING,
PERNR_ADP_COUNT TYPE STRING,
RETURN_QUGIR TYPE STRING,
RETURN_DATE TYPE STRING,
RETURN_PLANT TYPE STRING,
WERKS TYPE STRING,
LGORT_FROM TYPE STRING,
LGORT_TO TYPE STRING,
CHARG TYPE STRING,
RETURN_BATCH TYPE STRING,
RETURN_MCCODE TYPE STRING,
MAT_WBSELEM TYPE STRING,
UII TYPE STRING,
EXIDV_HU TYPE STRING,
EPA_ID TYPE STRING,
XBLNR TYPE STRING,
SGTXT TYPE STRING,
SRMDOCNO TYPE STRING,
SRMDOCITMNO TYPE STRING,
SBSTS TYPE STRING,
AED_REFER TYPE STRING,
ATM_REFER TYPE STRING,
COSTCENTER TYPE STRING,
MPO_MATNR TYPE STRING,
MPORIC TYPE STRING,
FORCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/S_BI_PA0800_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MANDT sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-PERNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SUBTY sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-OBJPS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SPRPS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ENDDA sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-BEGDA sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SEQNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-AEDTM sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-UNAME sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-HISTO sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ITXEX sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-REFEX sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ORDEX sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ITBLD sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-PREAS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-FLAG1 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-FLAG2 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-FLAG3 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-FLAG4 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RESE1 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RESE2 sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-GRPVL sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MATNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SERIAL sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MATTY sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-QUGIR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-STATUS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-STORAGE sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-UTYPE sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-IMATDOC sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-IMATPOS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RMATDOC sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RMATPOS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ORGEH_ID sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MPO_GUID sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MC_GUID sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-EPA_GUID sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MCCODE sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MEINS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-IVBELN sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-IPOSNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ORIG_ENDDA sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-LAST_ENDDA_UPD sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ENDDA_ADP_COUNT sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ORIG_PERNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-LAST_PERNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-PERNR_ADP_COUNT sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RETURN_QUGIR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RETURN_DATE sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RETURN_PLANT sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-WERKS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-LGORT_FROM sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-LGORT_TO sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-CHARG sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RETURN_BATCH sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-RETURN_MCCODE sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MAT_WBSELEM sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-UII sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-EXIDV_HU sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-EPA_ID sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-XBLNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SGTXT sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SRMDOCNO sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SRMDOCITMNO sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-SBSTS sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-AED_REFER sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-ATM_REFER sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-COSTCENTER sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MPO_MATNR sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-MPORIC sy-vline
WA_/ISDFPS/S_BI_PA0800_STR-FORCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.