ABAP Select data from SAP table /ISDFPS/ME_PM_FLOC_WARRANTY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/ME_PM_FLOC_WARRANTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/ME_PM_FLOC_WARRANTY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/ME_PM_FLOC_WARRANTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/ME_PM_FLOC_WARRANTY TYPE STANDARD TABLE OF /ISDFPS/ME_PM_FLOC_WARRANTY,
      WA_/ISDFPS/ME_PM_FLOC_WARRANTY TYPE /ISDFPS/ME_PM_FLOC_WARRANTY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/ME_PM_FLOC_WARRANTY> TYPE /ISDFPS/ME_PM_FLOC_WARRANTY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/ME_PM_FLOC_WARRANTY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/ME_PM_FLOC_WARRANTY
  INTO TABLE IT_/ISDFPS/ME_PM_FLOC_WARRANTY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/ME_PM_FLOC_WARRANTY
*  INTO TABLE @DATA(IT_/ISDFPS/ME_PM_FLOC_WARRANTY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/ME_PM_FLOC_WARRANTY INDEX 1 INTO DATA(WA_/ISDFPS/ME_PM_FLOC_WARRANTY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/ME_PM_FLOC_WARRANTY ASSIGNING </ISDFPS/ME_PM_FLOC_WARRANTY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/ME_PM_FLOC_WARRANTY>-OBJNR = 1.
</ISDFPS/ME_PM_FLOC_WARRANTY>-TPLNR = 1.
</ISDFPS/ME_PM_FLOC_WARRANTY>-WARRANTY_CATEGORY = 1.
</ISDFPS/ME_PM_FLOC_WARRANTY>-WARRANTY_TYPE = 1.
</ISDFPS/ME_PM_FLOC_WARRANTY>-WARRANTY_START = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/ME_PM_FLOC_WARRANTY INTO WA_/ISDFPS/ME_PM_FLOC_WARRANTY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/ME_PM_FLOC_WARRANTY-WARRANTY_END, sy-vline,
WA_/ISDFPS/ME_PM_FLOC_WARRANTY-MASTER_WARRANTY, sy-vline,
WA_/ISDFPS/ME_PM_FLOC_WARRANTY-CHECK_RESULT, sy-vline,
WA_/ISDFPS/ME_PM_FLOC_WARRANTY-CHECK_DATE, sy-vline,
WA_/ISDFPS/ME_PM_FLOC_WARRANTY-USR00, sy-vline,
WA_/ISDFPS/ME_PM_FLOC_WARRANTY-USR01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/ME_PM_FLOC_WARRANTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/ME_PM_FLOC_WARRANTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/ME_PM_FLOC_WARRANTY INTO WA_/ISDFPS/ME_PM_FLOC_WARRANTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_/ISDFPS/ME_PM_FLOC_WARRANTY-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/ME_PM_FLOC_WARRANTY-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MASTER_WARRANTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/ME_PM_FLOC_WARRANTY-MASTER_WARRANTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/ME_PM_FLOC_WARRANTY-MASTER_WARRANTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/ME_PM_FLOC_WARRANTY_STR,
OBJNR TYPE STRING,
TPLNR TYPE STRING,
WARRANTY_CATEGORY TYPE STRING,
WARRANTY_TYPE TYPE STRING,
WARRANTY_START TYPE STRING,
WARRANTY_END TYPE STRING,
MASTER_WARRANTY TYPE STRING,
CHECK_RESULT TYPE STRING,
CHECK_DATE TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USR05 TYPE STRING,
USR06 TYPE STRING,
USR07 TYPE STRING,
USR08 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-OBJNR sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-TPLNR sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-WARRANTY_CATEGORY sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-WARRANTY_TYPE sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-WARRANTY_START sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-WARRANTY_END sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-MASTER_WARRANTY sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-CHECK_RESULT sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-CHECK_DATE sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR00 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR01 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR02 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR03 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR04 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR05 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR06 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR07 sy-vline
WA_/ISDFPS/ME_PM_FLOC_WARRANTY_STR-USR08 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.