ABAP Select data from SAP table /ISDFPS/FDP_S_NOASSIGNMT_SLOCS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/FDP_S_NOASSIGNMT_SLOCS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/FDP_S_NOASSIGNMT_SLOCS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/FDP_S_NOASSIGNMT_SLOCS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS TYPE STANDARD TABLE OF /ISDFPS/FDP_S_NOASSIGNMT_SLOCS,
      WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS TYPE /ISDFPS/FDP_S_NOASSIGNMT_SLOCS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/FDP_S_NOASSIGNMT_SLOCS> TYPE /ISDFPS/FDP_S_NOASSIGNMT_SLOCS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/FDP_S_NOASSIGNMT_SLOCS
  INTO TABLE IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/FDP_S_NOASSIGNMT_SLOCS
*  INTO TABLE @DATA(IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS INDEX 1 INTO DATA(WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS ASSIGNING </ISDFPS/FDP_S_NOASSIGNMT_SLOCS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/FDP_S_NOASSIGNMT_SLOCS>-WERKS = 1.
</ISDFPS/FDP_S_NOASSIGNMT_SLOCS>-WERKS_NAME1 = 1.
</ISDFPS/FDP_S_NOASSIGNMT_SLOCS>-LGORTACNT = 1.
</ISDFPS/FDP_S_NOASSIGNMT_SLOCS>-LGOBE = 1.
</ISDFPS/FDP_S_NOASSIGNMT_SLOCS>-HU_LOC = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS INTO WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-OBJID, sy-vline,
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-PLVAR, sy-vline,
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-OTYPE, sy-vline,
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-SHORT, sy-vline,
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-STEXT, sy-vline,
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-ISTAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS INTO WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS-KUNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR,
WERKS TYPE STRING,
WERKS_NAME1 TYPE STRING,
LGORTACNT TYPE STRING,
LGOBE TYPE STRING,
HU_LOC TYPE STRING,
OBJID TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
ISTAT TYPE STRING,
BERID_S TYPE STRING,
ACNTABLE_S TYPE STRING,
BERTX TYPE STRING,
ORTZG TYPE STRING,
SPART TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
VSTEL TYPE STRING,
PRIO TYPE STRING,
LIFNR TYPE STRING,
KUNNR TYPE STRING,
XLONG TYPE STRING,
XBUFX TYPE STRING,
DISKZ TYPE STRING,
XBLGO TYPE STRING,
XRESS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-WERKS sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-WERKS_NAME1 sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-LGORTACNT sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-LGOBE sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-HU_LOC sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-OBJID sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-PLVAR sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-OTYPE sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-SHORT sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-STEXT sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-ISTAT sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-BERID_S sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-ACNTABLE_S sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-BERTX sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-ORTZG sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-SPART sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-VKORG sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-VTWEG sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-VSTEL sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-PRIO sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-LIFNR sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-KUNNR sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-XLONG sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-XBUFX sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-DISKZ sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-XBLGO sy-vline
WA_/ISDFPS/FDP_S_NOASSIGNMT_SLOCS_STR-XRESS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.