ABAP Select data from SAP table /ISDFPS/E1EQUI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/E1EQUI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/E1EQUI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/E1EQUI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/E1EQUI TYPE STANDARD TABLE OF /ISDFPS/E1EQUI,
      WA_/ISDFPS/E1EQUI TYPE /ISDFPS/E1EQUI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/E1EQUI> TYPE /ISDFPS/E1EQUI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/E1EQUI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/E1EQUI
  INTO TABLE IT_/ISDFPS/E1EQUI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/E1EQUI
*  INTO TABLE @DATA(IT_/ISDFPS/E1EQUI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/E1EQUI INDEX 1 INTO DATA(WA_/ISDFPS/E1EQUI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/E1EQUI ASSIGNING </ISDFPS/E1EQUI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/E1EQUI>-MANDT = 1.
</ISDFPS/E1EQUI>-EQUNR = 1.
</ISDFPS/E1EQUI>-ERDAT = 1.
</ISDFPS/E1EQUI>-ERNAM = 1.
</ISDFPS/E1EQUI>-EQASP = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/E1EQUI INTO WA_/ISDFPS/E1EQUI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/E1EQUI-AEDAT, sy-vline,
WA_/ISDFPS/E1EQUI-AENAM, sy-vline,
WA_/ISDFPS/E1EQUI-BEGRU, sy-vline,
WA_/ISDFPS/E1EQUI-EQTYP, sy-vline,
WA_/ISDFPS/E1EQUI-EQART, sy-vline,
WA_/ISDFPS/E1EQUI-LVORM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/E1EQUI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/E1EQUI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/E1EQUI INTO WA_/ISDFPS/E1EQUI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/E1EQUI_STR,
MANDT TYPE STRING,
EQUNR TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
EQASP TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
EQTYP TYPE STRING,
EQART TYPE STRING,
LVORM TYPE STRING,
INVNR TYPE STRING,
GROES TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
ANSDT TYPE STRING,
ANSWT TYPE STRING,
WAERS TYPE STRING,
ELIEF TYPE STRING,
GWLEN TYPE STRING,
GWLDT TYPE STRING,
WDBWT TYPE STRING,
HERST TYPE STRING,
HERLD TYPE STRING,
HZEIN TYPE STRING,
SERGE TYPE STRING,
TYPBZ TYPE STRING,
BAUJJ TYPE STRING,
BAUMM TYPE STRING,
APLKZ TYPE STRING,
AULDT TYPE STRING,
INBDT TYPE STRING,
GERNR TYPE STRING,
EQLFN TYPE STRING,
GWLDV TYPE STRING,
EQDAT TYPE STRING,
EQBER TYPE STRING,
EQNUM TYPE STRING,
OBJNR TYPE STRING,
EQSNR TYPE STRING,
CUOBJ TYPE STRING,
KRFKZ TYPE STRING,
KMATN TYPE STRING,
MATNR TYPE STRING,
SERNR TYPE STRING,
WERK TYPE STRING,
LAGER TYPE STRING,
CHARGE TYPE STRING,
KUNDE TYPE STRING,
WARPL TYPE STRING,
IMRC_POINT TYPE STRING,
REVLV TYPE STRING,
MGANR TYPE STRING,
BEGRUI TYPE STRING,
S_EQUI TYPE STRING,
S_SERIAL TYPE STRING,
S_KONFI TYPE STRING,
S_SALE TYPE STRING,
S_FHM TYPE STRING,
S_ELSE TYPE STRING,
S_ISU TYPE STRING,
S_EQBS TYPE STRING,
S_FLEET TYPE STRING,
BSTVP TYPE STRING,
SPARTE TYPE STRING,
HANDLE TYPE STRING,
TSEGTP TYPE STRING,
EMATN TYPE STRING,
ACT_CHANGE_AA TYPE STRING,
S_CC TYPE STRING,
DATLWB TYPE STRING,
EQEXT_ACTIVE TYPE STRING,
EQLB_DUTY TYPE STRING,
EQLB_HIDE TYPE STRING,
UII TYPE STRING,
IUID_TYPE TYPE STRING,
UII_PLANT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/E1EQUI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/E1EQUI_STR-MANDT sy-vline
WA_/ISDFPS/E1EQUI_STR-EQUNR sy-vline
WA_/ISDFPS/E1EQUI_STR-ERDAT sy-vline
WA_/ISDFPS/E1EQUI_STR-ERNAM sy-vline
WA_/ISDFPS/E1EQUI_STR-EQASP sy-vline
WA_/ISDFPS/E1EQUI_STR-AEDAT sy-vline
WA_/ISDFPS/E1EQUI_STR-AENAM sy-vline
WA_/ISDFPS/E1EQUI_STR-BEGRU sy-vline
WA_/ISDFPS/E1EQUI_STR-EQTYP sy-vline
WA_/ISDFPS/E1EQUI_STR-EQART sy-vline
WA_/ISDFPS/E1EQUI_STR-LVORM sy-vline
WA_/ISDFPS/E1EQUI_STR-INVNR sy-vline
WA_/ISDFPS/E1EQUI_STR-GROES sy-vline
WA_/ISDFPS/E1EQUI_STR-BRGEW sy-vline
WA_/ISDFPS/E1EQUI_STR-GEWEI sy-vline
WA_/ISDFPS/E1EQUI_STR-ANSDT sy-vline
WA_/ISDFPS/E1EQUI_STR-ANSWT sy-vline
WA_/ISDFPS/E1EQUI_STR-WAERS sy-vline
WA_/ISDFPS/E1EQUI_STR-ELIEF sy-vline
WA_/ISDFPS/E1EQUI_STR-GWLEN sy-vline
WA_/ISDFPS/E1EQUI_STR-GWLDT sy-vline
WA_/ISDFPS/E1EQUI_STR-WDBWT sy-vline
WA_/ISDFPS/E1EQUI_STR-HERST sy-vline
WA_/ISDFPS/E1EQUI_STR-HERLD sy-vline
WA_/ISDFPS/E1EQUI_STR-HZEIN sy-vline
WA_/ISDFPS/E1EQUI_STR-SERGE sy-vline
WA_/ISDFPS/E1EQUI_STR-TYPBZ sy-vline
WA_/ISDFPS/E1EQUI_STR-BAUJJ sy-vline
WA_/ISDFPS/E1EQUI_STR-BAUMM sy-vline
WA_/ISDFPS/E1EQUI_STR-APLKZ sy-vline
WA_/ISDFPS/E1EQUI_STR-AULDT sy-vline
WA_/ISDFPS/E1EQUI_STR-INBDT sy-vline
WA_/ISDFPS/E1EQUI_STR-GERNR sy-vline
WA_/ISDFPS/E1EQUI_STR-EQLFN sy-vline
WA_/ISDFPS/E1EQUI_STR-GWLDV sy-vline
WA_/ISDFPS/E1EQUI_STR-EQDAT sy-vline
WA_/ISDFPS/E1EQUI_STR-EQBER sy-vline
WA_/ISDFPS/E1EQUI_STR-EQNUM sy-vline
WA_/ISDFPS/E1EQUI_STR-OBJNR sy-vline
WA_/ISDFPS/E1EQUI_STR-EQSNR sy-vline
WA_/ISDFPS/E1EQUI_STR-CUOBJ sy-vline
WA_/ISDFPS/E1EQUI_STR-KRFKZ sy-vline
WA_/ISDFPS/E1EQUI_STR-KMATN sy-vline
WA_/ISDFPS/E1EQUI_STR-MATNR sy-vline
WA_/ISDFPS/E1EQUI_STR-SERNR sy-vline
WA_/ISDFPS/E1EQUI_STR-WERK sy-vline
WA_/ISDFPS/E1EQUI_STR-LAGER sy-vline
WA_/ISDFPS/E1EQUI_STR-CHARGE sy-vline
WA_/ISDFPS/E1EQUI_STR-KUNDE sy-vline
WA_/ISDFPS/E1EQUI_STR-WARPL sy-vline
WA_/ISDFPS/E1EQUI_STR-IMRC_POINT sy-vline
WA_/ISDFPS/E1EQUI_STR-REVLV sy-vline
WA_/ISDFPS/E1EQUI_STR-MGANR sy-vline
WA_/ISDFPS/E1EQUI_STR-BEGRUI sy-vline
WA_/ISDFPS/E1EQUI_STR-S_EQUI sy-vline
WA_/ISDFPS/E1EQUI_STR-S_SERIAL sy-vline
WA_/ISDFPS/E1EQUI_STR-S_KONFI sy-vline
WA_/ISDFPS/E1EQUI_STR-S_SALE sy-vline
WA_/ISDFPS/E1EQUI_STR-S_FHM sy-vline
WA_/ISDFPS/E1EQUI_STR-S_ELSE sy-vline
WA_/ISDFPS/E1EQUI_STR-S_ISU sy-vline
WA_/ISDFPS/E1EQUI_STR-S_EQBS sy-vline
WA_/ISDFPS/E1EQUI_STR-S_FLEET sy-vline
WA_/ISDFPS/E1EQUI_STR-BSTVP sy-vline
WA_/ISDFPS/E1EQUI_STR-SPARTE sy-vline
WA_/ISDFPS/E1EQUI_STR-HANDLE sy-vline
WA_/ISDFPS/E1EQUI_STR-TSEGTP sy-vline
WA_/ISDFPS/E1EQUI_STR-EMATN sy-vline
WA_/ISDFPS/E1EQUI_STR-ACT_CHANGE_AA sy-vline
WA_/ISDFPS/E1EQUI_STR-S_CC sy-vline
WA_/ISDFPS/E1EQUI_STR-DATLWB sy-vline
WA_/ISDFPS/E1EQUI_STR-EQEXT_ACTIVE sy-vline
WA_/ISDFPS/E1EQUI_STR-EQLB_DUTY sy-vline
WA_/ISDFPS/E1EQUI_STR-EQLB_HIDE sy-vline
WA_/ISDFPS/E1EQUI_STR-UII sy-vline
WA_/ISDFPS/E1EQUI_STR-IUID_TYPE sy-vline
WA_/ISDFPS/E1EQUI_STR-UII_PLANT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.