ABAP Select data from SAP table /INCMD/SCR_ITEM_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /INCMD/SCR_ITEM_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /INCMD/SCR_ITEM_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /INCMD/SCR_ITEM_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/INCMD/SCR_ITEM_DATA TYPE STANDARD TABLE OF /INCMD/SCR_ITEM_DATA,
      WA_/INCMD/SCR_ITEM_DATA TYPE /INCMD/SCR_ITEM_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </INCMD/SCR_ITEM_DATA> TYPE /INCMD/SCR_ITEM_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/INCMD/SCR_ITEM_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /INCMD/SCR_ITEM_DATA
  INTO TABLE IT_/INCMD/SCR_ITEM_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /INCMD/SCR_ITEM_DATA
*  INTO TABLE @DATA(IT_/INCMD/SCR_ITEM_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/INCMD/SCR_ITEM_DATA INDEX 1 INTO DATA(WA_/INCMD/SCR_ITEM_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/INCMD/SCR_ITEM_DATA ASSIGNING </INCMD/SCR_ITEM_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</INCMD/SCR_ITEM_DATA>-MEMEXT = 1.
</INCMD/SCR_ITEM_DATA>-MEMTYPE_DESC = 1.
</INCMD/SCR_ITEM_DATA>-PRODUCT_EXT = 1.
</INCMD/SCR_ITEM_DATA>-CMPEXT = 1.
</INCMD/SCR_ITEM_DATA>-PRODUCT_DESC = 1.
ENDLOOP.

LOOP AT IT_/INCMD/SCR_ITEM_DATA INTO WA_/INCMD/SCR_ITEM_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/INCMD/SCR_ITEM_DATA-KITLP_EXT, sy-vline,
WA_/INCMD/SCR_ITEM_DATA-CMPEXT, sy-vline,
WA_/INCMD/SCR_ITEM_DATA-KITLP_DESCR, sy-vline,
WA_/INCMD/SCR_ITEM_DATA-GROUP_DESCR, sy-vline,
WA_/INCMD/SCR_ITEM_DATA-LOC_EXT, sy-vline,
WA_/INCMD/SCR_ITEM_DATA-LOCEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/INCMD/SCR_ITEM_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/INCMD/SCR_ITEM_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/INCMD/SCR_ITEM_DATA INTO WA_/INCMD/SCR_ITEM_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/INCMD/SCR_ITEM_DATA-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/INCMD/SCR_ITEM_DATA-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/INCMD/SCR_ITEM_DATA-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/INCMD/SCR_ITEM_DATA-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/INCMD/SCR_ITEM_DATA-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/INCMD/SCR_ITEM_DATA-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/INCMD/SCR_ITEM_DATA-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/INCMD/SCR_ITEM_DATA-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/INCMD/SCR_ITEM_DATA_STR,
MEMEXT TYPE STRING,
MEMTYPE_DESC TYPE STRING,
PRODUCT_EXT TYPE STRING,
CMPEXT TYPE STRING,
PRODUCT_DESC TYPE STRING,
KITLP_EXT TYPE STRING,
CMPEXT TYPE STRING,
KITLP_DESCR TYPE STRING,
GROUP_DESCR TYPE STRING,
LOC_EXT TYPE STRING,
LOCEXT TYPE STRING,
LOC_DESC TYPE STRING,
SMEMEXT TYPE STRING,
MEMTYPE_DESC TYPE STRING,
PRODUCT_EXT TYPE STRING,
CMPEXT TYPE STRING,
PRODUCT_DESC TYPE STRING,
KITLP_EXT TYPE STRING,
CMPEXT TYPE STRING,
KITLP_DESCR TYPE STRING,
GROUP_DESCR TYPE STRING,
LOC_EXT TYPE STRING,
LOCEXT TYPE STRING,
LOC_DESC TYPE STRING,
SCR_RELTYPE TYPE STRING,
SCR_USEUPFLAG TYPE STRING,
REPTYPE_DESC TYPE STRING,
ICNO TYPE STRING,
ICSUBNO TYPE STRING,
PRGUID TYPE STRING,
SNO TYPE STRING,
PRODUCT_REFNO TYPE STRING,
FROMICNUM TYPE STRING,
SUCCPRODUCT_REFNO TYPE STRING,
TOICNUM TYPE STRING,
UPDFLG TYPE STRING,
MEMBER TYPE STRING,
PRODUCT TYPE STRING,
QUANT TYPE STRING,
MEINS TYPE STRING,
MEMTYPE TYPE STRING,
KITLP TYPE STRING,
TEXTFLG TYPE STRING,
PHASB TYPE STRING,
LOGOP TYPE STRING,
LOCID TYPE STRING,
SUCCMEMBER TYPE STRING,
PRODUCT TYPE STRING,
QUANT TYPE STRING,
MEINS TYPE STRING,
MEMTYPE TYPE STRING,
KITLP TYPE STRING,
TEXTFLG TYPE STRING,
PHASB TYPE STRING,
LOGOP TYPE STRING,
LOCID TYPE STRING,
BMEMTYPE TYPE STRING,
SUCCBMEMTYPE TYPE STRING,
REPTYPE TYPE STRING,
REPCNTR TYPE STRING,
VALIDFR TYPE STRING,
RELTYPE TYPE STRING,
RESCODE TYPE STRING,
USEUPFLG TYPE STRING,
USEUPDATE TYPE STRING,
USEUPQTY TYPE STRING,
UNIT TYPE STRING,
DENQUANT TYPE STRING,
NUMQUANT TYPE STRING,
FREETEXT TYPE STRING,
EXHAUSTDT TYPE STRING,
BACKCASTDT TYPE STRING,
EXHWRNDT TYPE STRING,
RULEPROF TYPE STRING,
PRIOFACT TYPE STRING,
DMNDPCNT TYPE STRING,
REALIGNSTDT TYPE STRING,
PREVALIDFR TYPE STRING,
TIMEFR TYPE STRING,
TIMETO TYPE STRING,
ACTIVITY TYPE STRING,
SUCCPDTRECEIPTDT TYPE STRING,
FINALDT TYPE STRING,
ICOST TYPE STRING,
FCOST TYPE STRING,
FROMPVGUID TYPE STRING,
TOPVGUID TYPE STRING,
FROMPNGUID TYPE STRING,
TOPNGUID TYPE STRING,
SPRAS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/INCMD/SCR_ITEM_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMTYPE_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-CMPEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-CMPEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP_DESCR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-GROUP_DESCR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOC_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOCEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOC_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SMEMEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMTYPE_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-CMPEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-CMPEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP_DESCR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-GROUP_DESCR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOC_EXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOCEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOC_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SCR_RELTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SCR_USEUPFLAG sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-REPTYPE_DESC sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-ICNO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-ICSUBNO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRGUID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SNO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT_REFNO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FROMICNUM sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SUCCPRODUCT_REFNO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TOICNUM sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-UPDFLG sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMBER sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-QUANT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEINS sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TEXTFLG sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PHASB sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOGOP sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOCID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SUCCMEMBER sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRODUCT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-QUANT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEINS sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-MEMTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-KITLP sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TEXTFLG sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PHASB sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOGOP sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-LOCID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-BMEMTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SUCCBMEMTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-REPTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-REPCNTR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-VALIDFR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-RELTYPE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-RESCODE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-USEUPFLG sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-USEUPDATE sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-USEUPQTY sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-UNIT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-DENQUANT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-NUMQUANT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FREETEXT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-EXHAUSTDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-BACKCASTDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-EXHWRNDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-RULEPROF sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PRIOFACT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-DMNDPCNT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-REALIGNSTDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-PREVALIDFR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TIMEFR sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TIMETO sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-ACTIVITY sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SUCCPDTRECEIPTDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FINALDT sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-ICOST sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FCOST sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FROMPVGUID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TOPVGUID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-FROMPNGUID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-TOPNGUID sy-vline
WA_/INCMD/SCR_ITEM_DATA_STR-SPRAS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.