ABAP Select data from SAP table /INCMD/INT_REL_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /INCMD/INT_REL_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /INCMD/INT_REL_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /INCMD/INT_REL_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/INCMD/INT_REL_DATA TYPE STANDARD TABLE OF /INCMD/INT_REL_DATA,
      WA_/INCMD/INT_REL_DATA TYPE /INCMD/INT_REL_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </INCMD/INT_REL_DATA> TYPE /INCMD/INT_REL_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/INCMD/INT_REL_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /INCMD/INT_REL_DATA
  INTO TABLE IT_/INCMD/INT_REL_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /INCMD/INT_REL_DATA
*  INTO TABLE @DATA(IT_/INCMD/INT_REL_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/INCMD/INT_REL_DATA INDEX 1 INTO DATA(WA_/INCMD/INT_REL_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/INCMD/INT_REL_DATA ASSIGNING </INCMD/INT_REL_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</INCMD/INT_REL_DATA>-ICNO = 1.
</INCMD/INT_REL_DATA>-PRGUID = 1.
</INCMD/INT_REL_DATA>-FROMREFNO = 1.
</INCMD/INT_REL_DATA>-TOREFNO = 1.
</INCMD/INT_REL_DATA>-FROMPROD = 1.
ENDLOOP.

LOOP AT IT_/INCMD/INT_REL_DATA INTO WA_/INCMD/INT_REL_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/INCMD/INT_REL_DATA-TOPROD, sy-vline,
WA_/INCMD/INT_REL_DATA-FROMICNUM, sy-vline,
WA_/INCMD/INT_REL_DATA-TOICNUM, sy-vline,
WA_/INCMD/INT_REL_DATA-FROMLOCID, sy-vline,
WA_/INCMD/INT_REL_DATA-TOLOCID, sy-vline,
WA_/INCMD/INT_REL_DATA-FROMPHASB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/INCMD/INT_REL_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/INCMD/INT_REL_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/INCMD/INT_REL_DATA INTO WA_/INCMD/INT_REL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/INCMD/INT_REL_DATA-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/INCMD/INT_REL_DATA-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/INCMD/INT_REL_DATA_STR,
ICNO TYPE STRING,
PRGUID TYPE STRING,
FROMREFNO TYPE STRING,
TOREFNO TYPE STRING,
FROMPROD TYPE STRING,
TOPROD TYPE STRING,
FROMICNUM TYPE STRING,
TOICNUM TYPE STRING,
FROMLOCID TYPE STRING,
TOLOCID TYPE STRING,
FROMPHASB TYPE STRING,
TOPHASB TYPE STRING,
REPTYPE TYPE STRING,
REPCNTR TYPE STRING,
VALIDFR TYPE STRING,
RELTYPE TYPE STRING,
RESCODE TYPE STRING,
USEUPFLG TYPE STRING,
USEUPDATE TYPE STRING,
USEUPQTY TYPE STRING,
UNIT TYPE STRING,
DENQUANT TYPE STRING,
NUMQUANT TYPE STRING,
FREETEXT TYPE STRING,
EXHAUSTDT TYPE STRING,
BACKCASTDT TYPE STRING,
EXHWRNDT TYPE STRING,
RULEPROF TYPE STRING,
PRIOFACT TYPE STRING,
DMNDPCNT TYPE STRING,
REALIGNSTDT TYPE STRING,
PREVALIDFR TYPE STRING,
TIMEFR TYPE STRING,
TIMETO TYPE STRING,
ACTIVITY TYPE STRING,
SUCCPDTRECEIPTDT TYPE STRING,
FINALDT TYPE STRING,
ICOST TYPE STRING,
FCOST TYPE STRING,
UPDFLG TYPE STRING,
FROMPVGUID TYPE STRING,
TOPVGUID TYPE STRING,
FROMPNGUID TYPE STRING,
TOPNGUID TYPE STRING,
SNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/INCMD/INT_REL_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/INCMD/INT_REL_DATA_STR-ICNO sy-vline
WA_/INCMD/INT_REL_DATA_STR-PRGUID sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMREFNO sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOREFNO sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMPROD sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOPROD sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMICNUM sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOICNUM sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMLOCID sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOLOCID sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMPHASB sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOPHASB sy-vline
WA_/INCMD/INT_REL_DATA_STR-REPTYPE sy-vline
WA_/INCMD/INT_REL_DATA_STR-REPCNTR sy-vline
WA_/INCMD/INT_REL_DATA_STR-VALIDFR sy-vline
WA_/INCMD/INT_REL_DATA_STR-RELTYPE sy-vline
WA_/INCMD/INT_REL_DATA_STR-RESCODE sy-vline
WA_/INCMD/INT_REL_DATA_STR-USEUPFLG sy-vline
WA_/INCMD/INT_REL_DATA_STR-USEUPDATE sy-vline
WA_/INCMD/INT_REL_DATA_STR-USEUPQTY sy-vline
WA_/INCMD/INT_REL_DATA_STR-UNIT sy-vline
WA_/INCMD/INT_REL_DATA_STR-DENQUANT sy-vline
WA_/INCMD/INT_REL_DATA_STR-NUMQUANT sy-vline
WA_/INCMD/INT_REL_DATA_STR-FREETEXT sy-vline
WA_/INCMD/INT_REL_DATA_STR-EXHAUSTDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-BACKCASTDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-EXHWRNDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-RULEPROF sy-vline
WA_/INCMD/INT_REL_DATA_STR-PRIOFACT sy-vline
WA_/INCMD/INT_REL_DATA_STR-DMNDPCNT sy-vline
WA_/INCMD/INT_REL_DATA_STR-REALIGNSTDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-PREVALIDFR sy-vline
WA_/INCMD/INT_REL_DATA_STR-TIMEFR sy-vline
WA_/INCMD/INT_REL_DATA_STR-TIMETO sy-vline
WA_/INCMD/INT_REL_DATA_STR-ACTIVITY sy-vline
WA_/INCMD/INT_REL_DATA_STR-SUCCPDTRECEIPTDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-FINALDT sy-vline
WA_/INCMD/INT_REL_DATA_STR-ICOST sy-vline
WA_/INCMD/INT_REL_DATA_STR-FCOST sy-vline
WA_/INCMD/INT_REL_DATA_STR-UPDFLG sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMPVGUID sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOPVGUID sy-vline
WA_/INCMD/INT_REL_DATA_STR-FROMPNGUID sy-vline
WA_/INCMD/INT_REL_DATA_STR-TOPNGUID sy-vline
WA_/INCMD/INT_REL_DATA_STR-SNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.