ABAP Select data from SAP table /INCMD/E1BPGRPLOCITEM01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /INCMD/E1BPGRPLOCITEM01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /INCMD/E1BPGRPLOCITEM01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /INCMD/E1BPGRPLOCITEM01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/INCMD/E1BPGRPLOCITEM01 TYPE STANDARD TABLE OF /INCMD/E1BPGRPLOCITEM01,
      WA_/INCMD/E1BPGRPLOCITEM01 TYPE /INCMD/E1BPGRPLOCITEM01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </INCMD/E1BPGRPLOCITEM01> TYPE /INCMD/E1BPGRPLOCITEM01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/INCMD/E1BPGRPLOCITEM01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /INCMD/E1BPGRPLOCITEM01
  INTO TABLE IT_/INCMD/E1BPGRPLOCITEM01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /INCMD/E1BPGRPLOCITEM01
*  INTO TABLE @DATA(IT_/INCMD/E1BPGRPLOCITEM012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/INCMD/E1BPGRPLOCITEM01 INDEX 1 INTO DATA(WA_/INCMD/E1BPGRPLOCITEM012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/INCMD/E1BPGRPLOCITEM01 ASSIGNING </INCMD/E1BPGRPLOCITEM01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</INCMD/E1BPGRPLOCITEM01>-ITEM_NUMBER = 1.
</INCMD/E1BPGRPLOCITEM01>-LOCATION = 1.
</INCMD/E1BPGRPLOCITEM01>-LOCTYPE = 1.
</INCMD/E1BPGRPLOCITEM01>-LOCATIONID_INT = 1.
</INCMD/E1BPGRPLOCITEM01>-LOCATION_ID = 1.
ENDLOOP.

LOOP AT IT_/INCMD/E1BPGRPLOCITEM01 INTO WA_/INCMD/E1BPGRPLOCITEM01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/INCMD/E1BPGRPLOCITEM01-DIRECTION_OF_INTERCHANGE, sy-vline,
WA_/INCMD/E1BPGRPLOCITEM01-USEUP_STRATEGY, sy-vline,
WA_/INCMD/E1BPGRPLOCITEM01-VALID_FROM_DATE, sy-vline,
WA_/INCMD/E1BPGRPLOCITEM01-USEUP_DATE, sy-vline,
WA_/INCMD/E1BPGRPLOCITEM01-REASON_CODE, sy-vline,
WA_/INCMD/E1BPGRPLOCITEM01-RULE_PROFILE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/INCMD/E1BPGRPLOCITEM01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/INCMD/E1BPGRPLOCITEM01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/INCMD/E1BPGRPLOCITEM01 INTO WA_/INCMD/E1BPGRPLOCITEM01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/INCMD/E1BPGRPLOCITEM01_STR,
ITEM_NUMBER TYPE STRING,
LOCATION TYPE STRING,
LOCTYPE TYPE STRING,
LOCATIONID_INT TYPE STRING,
LOCATION_ID TYPE STRING,
DIRECTION_OF_INTERCHANGE TYPE STRING,
USEUP_STRATEGY TYPE STRING,
VALID_FROM_DATE TYPE STRING,
USEUP_DATE TYPE STRING,
REASON_CODE TYPE STRING,
RULE_PROFILE TYPE STRING,
PRIORITY_FACTOR TYPE STRING,
PRECEDING_QUANTITY_FACTOR TYPE STRING,
SUCCEEDING_QUANTITY_FACTOR TYPE STRING,
DEMAND_PERCENTAGE_QUANTITY TYPE STRING,
STOCK_EXHAUSTION_DATE TYPE STRING,
SUCCESSOR_PRODUCT_PLAN_DATE TYPE STRING,
STOCK_EXHAUSTION_WARNING_DATE TYPE STRING,
REALIGNMENT_STOP_DATE TYPE STRING,
PRECEDING_VALID_FROM_DATE TYPE STRING,
SUCCESSOR_PRODUCT_RECEIPT_DATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/INCMD/E1BPGRPLOCITEM01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-ITEM_NUMBER sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-LOCATION sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-LOCTYPE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-LOCATIONID_INT sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-LOCATION_ID sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-DIRECTION_OF_INTERCHANGE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-USEUP_STRATEGY sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-VALID_FROM_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-USEUP_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-REASON_CODE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-RULE_PROFILE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-PRIORITY_FACTOR sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-PRECEDING_QUANTITY_FACTOR sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-SUCCEEDING_QUANTITY_FACTOR sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-DEMAND_PERCENTAGE_QUANTITY sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-STOCK_EXHAUSTION_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-SUCCESSOR_PRODUCT_PLAN_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-STOCK_EXHAUSTION_WARNING_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-REALIGNMENT_STOP_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-PRECEDING_VALID_FROM_DATE sy-vline
WA_/INCMD/E1BPGRPLOCITEM01_STR-SUCCESSOR_PRODUCT_RECEIPT_DATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.