ABAP Select data from SAP table /GRCPI/GRIA_S_ROLE_FLD_VAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /GRCPI/GRIA_S_ROLE_FLD_VAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /GRCPI/GRIA_S_ROLE_FLD_VAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /GRCPI/GRIA_S_ROLE_FLD_VAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/GRCPI/GRIA_S_ROLE_FLD_VAL TYPE STANDARD TABLE OF /GRCPI/GRIA_S_ROLE_FLD_VAL,
      WA_/GRCPI/GRIA_S_ROLE_FLD_VAL TYPE /GRCPI/GRIA_S_ROLE_FLD_VAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </GRCPI/GRIA_S_ROLE_FLD_VAL> TYPE /GRCPI/GRIA_S_ROLE_FLD_VAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/GRCPI/GRIA_S_ROLE_FLD_VAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /GRCPI/GRIA_S_ROLE_FLD_VAL
  INTO TABLE IT_/GRCPI/GRIA_S_ROLE_FLD_VAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /GRCPI/GRIA_S_ROLE_FLD_VAL
*  INTO TABLE @DATA(IT_/GRCPI/GRIA_S_ROLE_FLD_VAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/GRCPI/GRIA_S_ROLE_FLD_VAL INDEX 1 INTO DATA(WA_/GRCPI/GRIA_S_ROLE_FLD_VAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/GRCPI/GRIA_S_ROLE_FLD_VAL ASSIGNING </GRCPI/GRIA_S_ROLE_FLD_VAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</GRCPI/GRIA_S_ROLE_FLD_VAL>-FIELD = 1.
</GRCPI/GRIA_S_ROLE_FLD_VAL>-LOW = 1.
</GRCPI/GRIA_S_ROLE_FLD_VAL>-HIGH = 1.
</GRCPI/GRIA_S_ROLE_FLD_VAL>-MODIFIED = 1.
</GRCPI/GRIA_S_ROLE_FLD_VAL>-DELETED = 1.
ENDLOOP.

LOOP AT IT_/GRCPI/GRIA_S_ROLE_FLD_VAL INTO WA_/GRCPI/GRIA_S_ROLE_FLD_VAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/GRCPI/GRIA_S_ROLE_FLD_VAL-COPIED, sy-vline,
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL-NEU, sy-vline,
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL-NODE, sy-vline,
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL-COUNTER, sy-vline,
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL-FLAG_MODIFY, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/GRCPI/GRIA_S_ROLE_FLD_VAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/GRCPI/GRIA_S_ROLE_FLD_VAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/GRCPI/GRIA_S_ROLE_FLD_VAL INTO WA_/GRCPI/GRIA_S_ROLE_FLD_VAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR,
FIELD TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
MODIFIED TYPE STRING,
DELETED TYPE STRING,
COPIED TYPE STRING,
NEU TYPE STRING,
NODE TYPE STRING,
COUNTER TYPE STRING,
FLAG_MODIFY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-FIELD sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-LOW sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-HIGH sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-MODIFIED sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-DELETED sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-COPIED sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-NEU sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-NODE sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-COUNTER sy-vline
WA_/GRCPI/GRIA_S_ROLE_FLD_VAL_STR-FLAG_MODIFY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.