ABAP Select data from SAP table /GRCPI/GRIA_S_PRM_VIO_DET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /GRCPI/GRIA_S_PRM_VIO_DET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /GRCPI/GRIA_S_PRM_VIO_DET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /GRCPI/GRIA_S_PRM_VIO_DET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/GRCPI/GRIA_S_PRM_VIO_DET TYPE STANDARD TABLE OF /GRCPI/GRIA_S_PRM_VIO_DET,
      WA_/GRCPI/GRIA_S_PRM_VIO_DET TYPE /GRCPI/GRIA_S_PRM_VIO_DET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </GRCPI/GRIA_S_PRM_VIO_DET> TYPE /GRCPI/GRIA_S_PRM_VIO_DET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/GRCPI/GRIA_S_PRM_VIO_DET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /GRCPI/GRIA_S_PRM_VIO_DET
  INTO TABLE IT_/GRCPI/GRIA_S_PRM_VIO_DET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /GRCPI/GRIA_S_PRM_VIO_DET
*  INTO TABLE @DATA(IT_/GRCPI/GRIA_S_PRM_VIO_DET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/GRCPI/GRIA_S_PRM_VIO_DET INDEX 1 INTO DATA(WA_/GRCPI/GRIA_S_PRM_VIO_DET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/GRCPI/GRIA_S_PRM_VIO_DET ASSIGNING </GRCPI/GRIA_S_PRM_VIO_DET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</GRCPI/GRIA_S_PRM_VIO_DET>-ROLE_NAME = 1.
</GRCPI/GRIA_S_PRM_VIO_DET>-USER_ID = 1.
</GRCPI/GRIA_S_PRM_VIO_DET>-RISKID = 1.
</GRCPI/GRIA_S_PRM_VIO_DET>-RISK_DESC = 1.
</GRCPI/GRIA_S_PRM_VIO_DET>-ACTRULEID = 1.
ENDLOOP.

LOOP AT IT_/GRCPI/GRIA_S_PRM_VIO_DET INTO WA_/GRCPI/GRIA_S_PRM_VIO_DET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/GRCPI/GRIA_S_PRM_VIO_DET-FUNCTID, sy-vline,
WA_/GRCPI/GRIA_S_PRM_VIO_DET-XCONNECTOR, sy-vline,
WA_/GRCPI/GRIA_S_PRM_VIO_DET-ACTION, sy-vline,
WA_/GRCPI/GRIA_S_PRM_VIO_DET-RESOURCEID, sy-vline,
WA_/GRCPI/GRIA_S_PRM_VIO_DET-RESOURCEEXTN, sy-vline,
WA_/GRCPI/GRIA_S_PRM_VIO_DET-FROMVAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/GRCPI/GRIA_S_PRM_VIO_DET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/GRCPI/GRIA_S_PRM_VIO_DET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/GRCPI/GRIA_S_PRM_VIO_DET INTO WA_/GRCPI/GRIA_S_PRM_VIO_DET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/GRCPI/GRIA_S_PRM_VIO_DET_STR,
ROLE_NAME TYPE STRING,
USER_ID TYPE STRING,
RISKID TYPE STRING,
RISK_DESC TYPE STRING,
ACTRULEID TYPE STRING,
FUNCTID TYPE STRING,
XCONNECTOR TYPE STRING,
ACTION TYPE STRING,
RESOURCEID TYPE STRING,
RESOURCEEXTN TYPE STRING,
FROMVAL TYPE STRING,
TOVAL TYPE STRING,
ROLE TYPE STRING,
COMPROLE TYPE STRING,
ACCONTROLID TYPE STRING,
MONITOR TYPE STRING,
CONNECTOR TYPE STRING,
ORGRULEID TYPE STRING,
PRMSOURCE TYPE STRING,
RISKTYPE TYPE STRING,
OBJECTTYPE TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
ACTIVE TYPE STRING,
FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ROLE_NAME sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-USER_ID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-RISKID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-RISK_DESC sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ACTRULEID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-FUNCTID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-XCONNECTOR sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ACTION sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-RESOURCEID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-RESOURCEEXTN sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-FROMVAL sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-TOVAL sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ROLE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-COMPROLE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ACCONTROLID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-MONITOR sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-CONNECTOR sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ORGRULEID sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-PRMSOURCE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-RISKTYPE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-OBJECTTYPE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-VALIDFROM sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-VALIDTO sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-ACTIVE sy-vline
WA_/GRCPI/GRIA_S_PRM_VIO_DET_STR-FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.