ABAP Select data from SAP table /GEP/FLEET_S_0100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /GEP/FLEET_S_0100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /GEP/FLEET_S_0100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /GEP/FLEET_S_0100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/GEP/FLEET_S_0100 TYPE STANDARD TABLE OF /GEP/FLEET_S_0100,
      WA_/GEP/FLEET_S_0100 TYPE /GEP/FLEET_S_0100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </GEP/FLEET_S_0100> TYPE /GEP/FLEET_S_0100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/GEP/FLEET_S_0100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /GEP/FLEET_S_0100
  INTO TABLE IT_/GEP/FLEET_S_0100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /GEP/FLEET_S_0100
*  INTO TABLE @DATA(IT_/GEP/FLEET_S_01002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/GEP/FLEET_S_0100 INDEX 1 INTO DATA(WA_/GEP/FLEET_S_01002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/GEP/FLEET_S_0100 ASSIGNING </GEP/FLEET_S_0100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</GEP/FLEET_S_0100>-ERNAM = 1.
</GEP/FLEET_S_0100>-AENAM = 1.
</GEP/FLEET_S_0100>-ERDAT = 1.
</GEP/FLEET_S_0100>-AEDAT = 1.
</GEP/FLEET_S_0100>-QMART = 1.
ENDLOOP.

LOOP AT IT_/GEP/FLEET_S_0100 INTO WA_/GEP/FLEET_S_0100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/GEP/FLEET_S_0100-QMTXT, sy-vline,
WA_/GEP/FLEET_S_0100-KDMAT, sy-vline,
WA_/GEP/FLEET_S_0100-OBJNR, sy-vline,
WA_/GEP/FLEET_S_0100-IDNLF, sy-vline,
WA_/GEP/FLEET_S_0100-KAUFN, sy-vline,
WA_/GEP/FLEET_S_0100-KDAUF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/GEP/FLEET_S_0100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/GEP/FLEET_S_0100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/GEP/FLEET_S_0100 INTO WA_/GEP/FLEET_S_0100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field IDNLF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-IDNLF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-IDNLF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-KAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-KAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-KUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field /GEP/ANFEMAIL CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-/GEP/ANFEMAIL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-/GEP/ANFEMAIL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GEP/FLEET_S_0100-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GEP/FLEET_S_0100-AUFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/GEP/FLEET_S_0100_STR,
ERNAM TYPE STRING,
AENAM TYPE STRING,
ERDAT TYPE STRING,
AEDAT TYPE STRING,
QMART TYPE STRING,
QMTXT TYPE STRING,
KDMAT TYPE STRING,
OBJNR TYPE STRING,
IDNLF TYPE STRING,
KAUFN TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
KUNUM TYPE STRING,
/GEP/ANFNAME1 TYPE STRING,
/GEP/ANFNAME2 TYPE STRING,
/GEP/ANFTEL TYPE STRING,
/GEP/ANFEMAIL TYPE STRING,
MSAUS TYPE STRING,
/GEP/FAHRNAME1 TYPE STRING,
/GEP/FAHRSTREET TYPE STRING,
/GEP/FAHRCITY TYPE STRING,
/GEP/FAHRTEL TYPE STRING,
/GEP/LICENCENR TYPE STRING,
ADRNR TYPE STRING,
STRMN TYPE STRING,
STRUR TYPE STRING,
LTRMN TYPE STRING,
LTRUR TYPE STRING,
AUSVN TYPE STRING,
AUZTV TYPE STRING,
AUSBS TYPE STRING,
AUZTB TYPE STRING,
SWERK TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
/GEP/PASSENGER TYPE STRING,
/GEP/AUTOM TYPE STRING,
/GEP/KLIMA TYPE STRING,
/GEP/DACHG TYPE STRING,
/GEP/SCHNEEK TYPE STRING,
/GEP/WINTERR TYPE STRING,
/GEP/VHCAT TYPE STRING,
RADIO_KOSTL TYPE STRING,
RADIO_AUFNR TYPE STRING,
RADIO_KDANR TYPE STRING,
RADIO_KUNNR TYPE STRING,
AUFNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/GEP/FLEET_S_0100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/GEP/FLEET_S_0100_STR-ERNAM sy-vline
WA_/GEP/FLEET_S_0100_STR-AENAM sy-vline
WA_/GEP/FLEET_S_0100_STR-ERDAT sy-vline
WA_/GEP/FLEET_S_0100_STR-AEDAT sy-vline
WA_/GEP/FLEET_S_0100_STR-QMART sy-vline
WA_/GEP/FLEET_S_0100_STR-QMTXT sy-vline
WA_/GEP/FLEET_S_0100_STR-KDMAT sy-vline
WA_/GEP/FLEET_S_0100_STR-OBJNR sy-vline
WA_/GEP/FLEET_S_0100_STR-IDNLF sy-vline
WA_/GEP/FLEET_S_0100_STR-KAUFN sy-vline
WA_/GEP/FLEET_S_0100_STR-KDAUF sy-vline
WA_/GEP/FLEET_S_0100_STR-KDPOS sy-vline
WA_/GEP/FLEET_S_0100_STR-KUNUM sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/ANFNAME1 sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/ANFNAME2 sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/ANFTEL sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/ANFEMAIL sy-vline
WA_/GEP/FLEET_S_0100_STR-MSAUS sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/FAHRNAME1 sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/FAHRSTREET sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/FAHRCITY sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/FAHRTEL sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/LICENCENR sy-vline
WA_/GEP/FLEET_S_0100_STR-ADRNR sy-vline
WA_/GEP/FLEET_S_0100_STR-STRMN sy-vline
WA_/GEP/FLEET_S_0100_STR-STRUR sy-vline
WA_/GEP/FLEET_S_0100_STR-LTRMN sy-vline
WA_/GEP/FLEET_S_0100_STR-LTRUR sy-vline
WA_/GEP/FLEET_S_0100_STR-AUSVN sy-vline
WA_/GEP/FLEET_S_0100_STR-AUZTV sy-vline
WA_/GEP/FLEET_S_0100_STR-AUSBS sy-vline
WA_/GEP/FLEET_S_0100_STR-AUZTB sy-vline
WA_/GEP/FLEET_S_0100_STR-SWERK sy-vline
WA_/GEP/FLEET_S_0100_STR-EQUNR sy-vline
WA_/GEP/FLEET_S_0100_STR-TPLNR sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/PASSENGER sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/AUTOM sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/KLIMA sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/DACHG sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/SCHNEEK sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/WINTERR sy-vline
WA_/GEP/FLEET_S_0100_STR-/GEP/VHCAT sy-vline
WA_/GEP/FLEET_S_0100_STR-RADIO_KOSTL sy-vline
WA_/GEP/FLEET_S_0100_STR-RADIO_AUFNR sy-vline
WA_/GEP/FLEET_S_0100_STR-RADIO_KDANR sy-vline
WA_/GEP/FLEET_S_0100_STR-RADIO_KUNNR sy-vline
WA_/GEP/FLEET_S_0100_STR-AUFNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.