ABAP Select data from SAP table /GBT/S_DLIO_NODE_STRUCT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /GBT/S_DLIO_NODE_STRUCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /GBT/S_DLIO_NODE_STRUCT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /GBT/S_DLIO_NODE_STRUCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/GBT/S_DLIO_NODE_STRUCT TYPE STANDARD TABLE OF /GBT/S_DLIO_NODE_STRUCT,
      WA_/GBT/S_DLIO_NODE_STRUCT TYPE /GBT/S_DLIO_NODE_STRUCT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </GBT/S_DLIO_NODE_STRUCT> TYPE /GBT/S_DLIO_NODE_STRUCT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/GBT/S_DLIO_NODE_STRUCT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /GBT/S_DLIO_NODE_STRUCT
  INTO TABLE IT_/GBT/S_DLIO_NODE_STRUCT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /GBT/S_DLIO_NODE_STRUCT
*  INTO TABLE @DATA(IT_/GBT/S_DLIO_NODE_STRUCT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/GBT/S_DLIO_NODE_STRUCT INDEX 1 INTO DATA(WA_/GBT/S_DLIO_NODE_STRUCT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/GBT/S_DLIO_NODE_STRUCT ASSIGNING </GBT/S_DLIO_NODE_STRUCT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</GBT/S_DLIO_NODE_STRUCT>-OBJ_GUID = 1.
</GBT/S_DLIO_NODE_STRUCT>-DLVYNR = 1.
</GBT/S_DLIO_NODE_STRUCT>-CRYEAR = 1.
</GBT/S_DLIO_NODE_STRUCT>-DLVYIT = 1.
</GBT/S_DLIO_NODE_STRUCT>-LOGSYS = 1.
ENDLOOP.

LOOP AT IT_/GBT/S_DLIO_NODE_STRUCT INTO WA_/GBT/S_DLIO_NODE_STRUCT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/GBT/S_DLIO_NODE_STRUCT-MAT_DESCR, sy-vline,
WA_/GBT/S_DLIO_NODE_STRUCT-PRODUCT_GUID, sy-vline,
WA_/GBT/S_DLIO_NODE_STRUCT-INSERTED_AT, sy-vline,
WA_/GBT/S_DLIO_NODE_STRUCT-MODIFIED_AT, sy-vline,
WA_/GBT/S_DLIO_NODE_STRUCT-CREATED_DATE, sy-vline,
WA_/GBT/S_DLIO_NODE_STRUCT-CREATED_TIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/GBT/S_DLIO_NODE_STRUCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/GBT/S_DLIO_NODE_STRUCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/GBT/S_DLIO_NODE_STRUCT INTO WA_/GBT/S_DLIO_NODE_STRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DLVYNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-DLVYNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-DLVYNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SHIP_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-SHIP_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-SHIP_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOLD_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-SOLD_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-SOLD_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VENDOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-VENDOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-VENDOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CITY_CODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-CITY_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-CITY_CODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CITYP_CODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-CITYP_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-CITYP_CODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STREETCODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-STREETCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-STREETCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GBTM1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_GBTM1_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SALNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-SALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-SALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GBTM1, internal->external for field MOVE_MATL CALL FUNCTION 'CONVERSION_EXIT_GBTM1_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-MOVE_MATL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-MOVE_MATL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SALES_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/GBT/S_DLIO_NODE_STRUCT-SALES_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GBT/S_DLIO_NODE_STRUCT-SALES_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/GBT/S_DLIO_NODE_STRUCT_STR,
OBJ_GUID TYPE STRING,
DLVYNR TYPE STRING,
CRYEAR TYPE STRING,
DLVYIT TYPE STRING,
LOGSYS TYPE STRING,
MAT_DESCR TYPE STRING,
PRODUCT_GUID TYPE STRING,
INSERTED_AT TYPE STRING,
MODIFIED_AT TYPE STRING,
CREATED_DATE TYPE STRING,
CREATED_TIME TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_DATE TYPE STRING,
CHANGED_TIME TYPE STRING,
CHANGED_BY TYPE STRING,
TIMEZONE_DLV TYPE STRING,
TIMEZONE_REC TYPE STRING,
ADDRNUMBER TYPE STRING,
DLV_TYPE TYPE STRING,
DOC_DATE TYPE STRING,
GI_DATE TYPE STRING,
SHIP_TO TYPE STRING,
SOLD_TO TYPE STRING,
VENDOR TYPE STRING,
SALES_DIST TYPE STRING,
SHIP_POINT TYPE STRING,
SALESORG TYPE STRING,
RCV_PLANT TYPE STRING,
SHIP_TYPE TYPE STRING,
SUPPLYAREA TYPE STRING,
EXTDELV_NO TYPE STRING,
CONSIGNEE TYPE STRING,
CONSIGNEE_ADR TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
CITY1 TYPE STRING,
CITY2 TYPE STRING,
CITY_CODE TYPE STRING,
CITYP_CODE TYPE STRING,
TRANSPZONE TYPE STRING,
STREET TYPE STRING,
STREETCODE TYPE STRING,
HOUSE_NUM1 TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
SORT1 TYPE STRING,
SORT2 TYPE STRING,
TIME_ZONE TYPE STRING,
DELIV_ITEM_CAT TYPE STRING,
PLANT TYPE STRING,
STGE_LOC TYPE STRING,
MATNR TYPE STRING,
BATNR TYPE STRING,
MOVE_TYPE TYPE STRING,
TRANS_GRP TYPE STRING,
LOADINGGRP TYPE STRING,
WHSENUMBER TYPE STRING,
STGE_TYPE TYPE STRING,
STGE_BIN TYPE STRING,
BUS_AREA TYPE STRING,
SALES_OFF TYPE STRING,
SALES_GRP TYPE STRING,
DISTR_CHAN TYPE STRING,
DIVISION TYPE STRING,
SALNR TYPE STRING,
SALIT TYPE STRING,
REC_POINT TYPE STRING,
MVT_IND TYPE STRING,
MOVE_MATL TYPE STRING,
MOVE_PLANT TYPE STRING,
MOVE_STLOC TYPE STRING,
MOVE_BATCH TYPE STRING,
DLV_QTY TYPE STRING,
SALES_UNIT TYPE STRING,
FLAG_TRANSFER TYPE STRING,END OF T_EKKO_STR. DATA: WA_/GBT/S_DLIO_NODE_STRUCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-OBJ_GUID sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DLVYNR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CRYEAR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DLVYIT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-LOGSYS sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MAT_DESCR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-PRODUCT_GUID sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-INSERTED_AT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MODIFIED_AT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CREATED_DATE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CREATED_TIME sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CREATED_BY sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CHANGED_DATE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CHANGED_TIME sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CHANGED_BY sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-TIMEZONE_DLV sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-TIMEZONE_REC sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-ADDRNUMBER sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DLV_TYPE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DOC_DATE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-GI_DATE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SHIP_TO sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SOLD_TO sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-VENDOR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALES_DIST sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SHIP_POINT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALESORG sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-RCV_PLANT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SHIP_TYPE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SUPPLYAREA sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-EXTDELV_NO sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CONSIGNEE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CONSIGNEE_ADR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-NAME1 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-NAME2 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CITY1 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CITY2 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CITY_CODE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-CITYP_CODE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-TRANSPZONE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-STREET sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-STREETCODE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-HOUSE_NUM1 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-COUNTRY sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-REGION sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SORT1 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SORT2 sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-TIME_ZONE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DELIV_ITEM_CAT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-PLANT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-STGE_LOC sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MATNR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-BATNR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MOVE_TYPE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-TRANS_GRP sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-LOADINGGRP sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-WHSENUMBER sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-STGE_TYPE sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-STGE_BIN sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-BUS_AREA sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALES_OFF sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALES_GRP sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DISTR_CHAN sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DIVISION sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALNR sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALIT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-REC_POINT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MVT_IND sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MOVE_MATL sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MOVE_PLANT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MOVE_STLOC sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-MOVE_BATCH sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-DLV_QTY sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-SALES_UNIT sy-vline
WA_/GBT/S_DLIO_NODE_STRUCT_STR-FLAG_TRANSFER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.