ABAP Select data from SAP table /DMBE/S_ICPFPARAMETERDRAFT_TP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /DMBE/S_ICPFPARAMETERDRAFT_TP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /DMBE/S_ICPFPARAMETERDRAFT_TP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /DMBE/S_ICPFPARAMETERDRAFT_TP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/DMBE/S_ICPFPARAMETERDRAFT_TP TYPE STANDARD TABLE OF /DMBE/S_ICPFPARAMETERDRAFT_TP,
      WA_/DMBE/S_ICPFPARAMETERDRAFT_TP TYPE /DMBE/S_ICPFPARAMETERDRAFT_TP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </DMBE/S_ICPFPARAMETERDRAFT_TP> TYPE /DMBE/S_ICPFPARAMETERDRAFT_TP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/DMBE/S_ICPFPARAMETERDRAFT_TP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /DMBE/S_ICPFPARAMETERDRAFT_TP
  INTO TABLE IT_/DMBE/S_ICPFPARAMETERDRAFT_TP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /DMBE/S_ICPFPARAMETERDRAFT_TP
*  INTO TABLE @DATA(IT_/DMBE/S_ICPFPARAMETERDRAFT_TP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/DMBE/S_ICPFPARAMETERDRAFT_TP INDEX 1 INTO DATA(WA_/DMBE/S_ICPFPARAMETERDRAFT_TP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/DMBE/S_ICPFPARAMETERDRAFT_TP ASSIGNING </DMBE/S_ICPFPARAMETERDRAFT_TP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</DMBE/S_ICPFPARAMETERDRAFT_TP>-KEY = 1.
</DMBE/S_ICPFPARAMETERDRAFT_TP>-PARENT_KEY = 1.
</DMBE/S_ICPFPARAMETERDRAFT_TP>-ROOT_KEY = 1.
</DMBE/S_ICPFPARAMETERDRAFT_TP>-PRICINGUUID = 1.
</DMBE/S_ICPFPARAMETERDRAFT_TP>-DEALUUID = 1.
ENDLOOP.

LOOP AT IT_/DMBE/S_ICPFPARAMETERDRAFT_TP INTO WA_/DMBE/S_ICPFPARAMETERDRAFT_TP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERNAME, sy-vline,
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-SUBPARAMETER, sy-vline,
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERVALUE, sy-vline,
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERAMOUNT, sy-vline,
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERCURRENCY, sy-vline,
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERQUANTITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/DMBE/S_ICPFPARAMETERDRAFT_TP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/DMBE/S_ICPFPARAMETERDRAFT_TP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/DMBE/S_ICPFPARAMETERDRAFT_TP INTO WA_/DMBE/S_ICPFPARAMETERDRAFT_TP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DCCUR, internal->external for field PARAMETERAMOUNT CALL FUNCTION 'CONVERSION_EXIT_DCCUR_OUTPUT' EXPORTING input = WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERAMOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERAMOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARAMETERUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-PARAMETERUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEPARAMETERUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-BASEPARAMETERUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/DMBE/S_ICPFPARAMETERDRAFT_TP-BASEPARAMETERUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
PRICINGUUID TYPE STRING,
DEALUUID TYPE STRING,
PARAMETERNAME TYPE STRING,
SUBPARAMETER TYPE STRING,
PARAMETERVALUE TYPE STRING,
PARAMETERAMOUNT TYPE STRING,
PARAMETERCURRENCY TYPE STRING,
PARAMETERQUANTITY TYPE STRING,
PARAMETERUOM TYPE STRING,
CONDITIONTYPE TYPE STRING,
PARAMETERSEQUENCE TYPE STRING,
ISUSINGSCALES TYPE STRING,
SCALESTARTASC TYPE STRING,
SCALESTARTDESC TYPE STRING,
SCALEBASEPARAMETER TYPE STRING,
SCALEBASESUBPARAMETER TYPE STRING,
SCALEEVALROUTINE TYPE STRING,
SCALETYPE TYPE STRING,
QUALITYNAME TYPE STRING,
PERCENTAGE TYPE STRING,
CPFNUMBER TYPE STRING,
CREATEDBY TYPE STRING,
CREATEDAT TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDAT TYPE STRING,
ETAG TYPE STRING,
DELETED TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
BASEPARAMETERUUID TYPE STRING,
BASEPARAMETERCURRENCY TYPE STRING,
BASEPARAMETERUOM TYPE STRING,
BASEPARAMETERFIELDTYPE TYPE STRING,
DETAILTRANSACTIONTYPE TYPE STRING,
DETAILAPPLICATION TYPE STRING,
DETAILPRICINGPROCEDURE TYPE STRING,
HEADERTRANSACTIONTYPE TYPE STRING,
REFDATATYPE TYPE STRING,
DATACATEGORY TYPE STRING,
DATASOURCEROUTINE TYPE STRING,
FIELDTYPE TYPE STRING,
PARAMETERDESC TYPE STRING,
INTERNALCOMPANY TYPE STRING,
BUYINGCOMPANY TYPE STRING,
SELLINGCOMPANY TYPE STRING,
PRODUCTTYPE TYPE STRING,
DEALTYPE TYPE STRING,
TRANSACTIONTYPE TYPE STRING,
DEALBLOCKED TYPE STRING,END OF T_EKKO_STR. DATA: WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-KEY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARENT_KEY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-ROOT_KEY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PRICINGUUID sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DEALUUID sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERNAME sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SUBPARAMETER sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERVALUE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERAMOUNT sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERCURRENCY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERQUANTITY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERUOM sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CONDITIONTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERSEQUENCE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-ISUSINGSCALES sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALESTARTASC sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALESTARTDESC sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALEBASEPARAMETER sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALEBASESUBPARAMETER sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALEEVALROUTINE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SCALETYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-QUALITYNAME sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PERCENTAGE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CPFNUMBER sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CREATEDBY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CREATEDAT sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CHANGEDBY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-CHANGEDAT sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-ETAG sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DELETED sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-ACTIVEUUID sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-HASACTIVEENTITY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-BASEPARAMETERUUID sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-BASEPARAMETERCURRENCY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-BASEPARAMETERUOM sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-BASEPARAMETERFIELDTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DETAILTRANSACTIONTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DETAILAPPLICATION sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DETAILPRICINGPROCEDURE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-HEADERTRANSACTIONTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-REFDATATYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DATACATEGORY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DATASOURCEROUTINE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-FIELDTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PARAMETERDESC sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-INTERNALCOMPANY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-BUYINGCOMPANY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-SELLINGCOMPANY sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-PRODUCTTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DEALTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-TRANSACTIONTYPE sy-vline
WA_/DMBE/S_ICPFPARAMETERDRAFT_TP_STR-DEALBLOCKED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.