ABAP Select data from SAP table /BOFU/S_BCSR_REPLY_TO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BOFU/S_BCSR_REPLY_TO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BOFU/S_BCSR_REPLY_TO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BOFU/S_BCSR_REPLY_TO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BOFU/S_BCSR_REPLY_TO TYPE STANDARD TABLE OF /BOFU/S_BCSR_REPLY_TO,
      WA_/BOFU/S_BCSR_REPLY_TO TYPE /BOFU/S_BCSR_REPLY_TO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BOFU/S_BCSR_REPLY_TO> TYPE /BOFU/S_BCSR_REPLY_TO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BOFU/S_BCSR_REPLY_TO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BOFU/S_BCSR_REPLY_TO
  INTO TABLE IT_/BOFU/S_BCSR_REPLY_TO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BOFU/S_BCSR_REPLY_TO
*  INTO TABLE @DATA(IT_/BOFU/S_BCSR_REPLY_TO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BOFU/S_BCSR_REPLY_TO INDEX 1 INTO DATA(WA_/BOFU/S_BCSR_REPLY_TO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BOFU/S_BCSR_REPLY_TO ASSIGNING </BOFU/S_BCSR_REPLY_TO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BOFU/S_BCSR_REPLY_TO>-USER = 1.
</BOFU/S_BCSR_REPLY_TO>-USERNAME = 1.
</BOFU/S_BCSR_REPLY_TO>-USRTP = 1.
</BOFU/S_BCSR_REPLY_TO>-USRYR = 1.
</BOFU/S_BCSR_REPLY_TO>-USRNO = 1.
ENDLOOP.

LOOP AT IT_/BOFU/S_BCSR_REPLY_TO INTO WA_/BOFU/S_BCSR_REPLY_TO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BOFU/S_BCSR_REPLY_TO-DLI, sy-vline,
WA_/BOFU/S_BCSR_REPLY_TO-DLINAME, sy-vline,
WA_/BOFU/S_BCSR_REPLY_TO-PRIVATE, sy-vline,
WA_/BOFU/S_BCSR_REPLY_TO-OBJTP, sy-vline,
WA_/BOFU/S_BCSR_REPLY_TO-OBJYR, sy-vline,
WA_/BOFU/S_BCSR_REPLY_TO-OBJNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BOFU/S_BCSR_REPLY_TO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BOFU/S_BCSR_REPLY_TO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BOFU/S_BCSR_REPLY_TO INTO WA_/BOFU/S_BCSR_REPLY_TO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BOFU/S_BCSR_REPLY_TO-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BOFU/S_BCSR_REPLY_TO-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BOFU/S_BCSR_REPLY_TO-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BOFU/S_BCSR_REPLY_TO-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PERSNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BOFU/S_BCSR_REPLY_TO-PERSNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BOFU/S_BCSR_REPLY_TO-PERSNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SO_KEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BOFU/S_BCSR_REPLY_TO-SO_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BOFU/S_BCSR_REPLY_TO-SO_KEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field DEVICE CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_/BOFU/S_BCSR_REPLY_TO-DEVICE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BOFU/S_BCSR_REPLY_TO-DEVICE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BOFU/S_BCSR_REPLY_TO_STR,
USER TYPE STRING,
USERNAME TYPE STRING,
USRTP TYPE STRING,
USRYR TYPE STRING,
USRNO TYPE STRING,
DLI TYPE STRING,
DLINAME TYPE STRING,
PRIVATE TYPE STRING,
OBJTP TYPE STRING,
OBJYR TYPE STRING,
OBJNO TYPE STRING,
ORG_UNIT TYPE STRING,
BOR_OBJECT TYPE STRING,
OBJKEY TYPE STRING,
OBJTYPE TYPE STRING,
LOGSYS TYPE STRING,
CAM_ADDRES TYPE STRING,
ADDRNUMBER TYPE STRING,
PERSNUMBER TYPE STRING,
COMMTYPE TYPE STRING,
CONSNUMBER TYPE STRING,
SO_KEY TYPE STRING,
SPOOL TYPE STRING,
DEPARTMENT TYPE STRING,
COVER TYPE STRING,
COVERTEXT TYPE STRING,
AUTHORIZTN TYPE STRING,
DEVICE TYPE STRING,
SPOOLNAME TYPE STRING,
SUFFIX1 TYPE STRING,
SUFFIX2 TYPE STRING,
PRNTIMMED TYPE STRING,
DELSPOOL TYPE STRING,
COPIES TYPE STRING,
NEWSPOOL TYPE STRING,
TDGROUP TYPE STRING,
RECIPIENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BOFU/S_BCSR_REPLY_TO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-USER sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-USERNAME sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-USRTP sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-USRYR sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-USRNO sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-DLI sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-DLINAME sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-PRIVATE sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-OBJTP sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-OBJYR sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-OBJNO sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-ORG_UNIT sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-BOR_OBJECT sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-OBJKEY sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-OBJTYPE sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-LOGSYS sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-CAM_ADDRES sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-ADDRNUMBER sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-PERSNUMBER sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-COMMTYPE sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-CONSNUMBER sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-SO_KEY sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-SPOOL sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-DEPARTMENT sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-COVER sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-COVERTEXT sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-AUTHORIZTN sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-DEVICE sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-SPOOLNAME sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-SUFFIX1 sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-SUFFIX2 sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-PRNTIMMED sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-DELSPOOL sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-COPIES sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-NEWSPOOL sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-TDGROUP sy-vline
WA_/BOFU/S_BCSR_REPLY_TO_STR-RECIPIENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.