ABAP Select data from SAP table /BIC/CCTA0TCT_DSA1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0TCT_DSA1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0TCT_DSA1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0TCT_DSA1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0TCT_DSA1 TYPE STANDARD TABLE OF /BIC/CCTA0TCT_DSA1,
      WA_/BIC/CCTA0TCT_DSA1 TYPE /BIC/CCTA0TCT_DSA1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0TCT_DSA1> TYPE /BIC/CCTA0TCT_DSA1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0TCT_DSA1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0TCT_DSA1
  INTO TABLE IT_/BIC/CCTA0TCT_DSA1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0TCT_DSA1
*  INTO TABLE @DATA(IT_/BIC/CCTA0TCT_DSA12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0TCT_DSA1 INDEX 1 INTO DATA(WA_/BIC/CCTA0TCT_DSA12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0TCT_DSA1 ASSIGNING </BIC/CCTA0TCT_DSA1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0TCT_DSA1>-UNAME = 1.
</BIC/CCTA0TCT_DSA1>-CALDAY = 1.
</BIC/CCTA0TCT_DSA1>-CALWEEK = 1.
</BIC/CCTA0TCT_DSA1>-CALMONTH = 1.
</BIC/CCTA0TCT_DSA1>-INFOPROV = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0TCT_DSA1 INTO WA_/BIC/CCTA0TCT_DSA1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0TCT_DSA1-STARTTIME, sy-vline,
WA_/BIC/CCTA0TCT_DSA1-INFOPROV_TYPE, sy-vline,
WA_/BIC/CCTA0TCT_DSA1-LOGSYS, sy-vline,
WA_/BIC/CCTA0TCT_DSA1-OBJECT, sy-vline,
WA_/BIC/CCTA0TCT_DSA1-OBJECT_TYPE, sy-vline,
WA_/BIC/CCTA0TCT_DSA1-SUB_OBJECT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0TCT_DSA1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0TCT_DSA1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0TCT_DSA1 INTO WA_/BIC/CCTA0TCT_DSA1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0TCT_DSA1_STR,
UNAME TYPE STRING,
CALDAY TYPE STRING,
CALWEEK TYPE STRING,
CALMONTH TYPE STRING,
INFOPROV TYPE STRING,
STARTTIME TYPE STRING,
INFOPROV_TYPE TYPE STRING,
LOGSYS TYPE STRING,
OBJECT TYPE STRING,
OBJECT_TYPE TYPE STRING,
SUB_OBJECT TYPE STRING,
SUB_OBJECT_TYPE TYPE STRING,
TIME_FE TYPE STRING,
TIME_OLAP TYPE STRING,
TIME_DM TYPE STRING,
TIME_PLAN TYPE STRING,
TIME_NOTASSIGNED TYPE STRING,
TIME_OVERALL TYPE STRING,
QUERY_COUNTER TYPE STRING,
TEMPLATE_COUNTER TYPE STRING,
INIT_NAV_FLAG TYPE STRING,
CALYEAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0TCT_DSA1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-UNAME sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-CALDAY sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-CALWEEK sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-CALMONTH sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-INFOPROV sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-STARTTIME sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-INFOPROV_TYPE sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-LOGSYS sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-OBJECT sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-OBJECT_TYPE sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-SUB_OBJECT sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-SUB_OBJECT_TYPE sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_FE sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_OLAP sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_DM sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_PLAN sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_NOTASSIGNED sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TIME_OVERALL sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-QUERY_COUNTER sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-TEMPLATE_COUNTER sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-INIT_NAV_FLAG sy-vline
WA_/BIC/CCTA0TCT_DSA1_STR-CALYEAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.