ABAP Select data from SAP table /BIC/CCTA0SETTLEUNIT_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0SETTLEUNIT_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0SETTLEUNIT_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0SETTLEUNIT_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0SETTLEUNIT_ATTR TYPE STANDARD TABLE OF /BIC/CCTA0SETTLEUNIT_ATTR,
      WA_/BIC/CCTA0SETTLEUNIT_ATTR TYPE /BIC/CCTA0SETTLEUNIT_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0SETTLEUNIT_ATTR> TYPE /BIC/CCTA0SETTLEUNIT_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0SETTLEUNIT_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0SETTLEUNIT_ATTR
  INTO TABLE IT_/BIC/CCTA0SETTLEUNIT_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0SETTLEUNIT_ATTR
*  INTO TABLE @DATA(IT_/BIC/CCTA0SETTLEUNIT_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0SETTLEUNIT_ATTR INDEX 1 INTO DATA(WA_/BIC/CCTA0SETTLEUNIT_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0SETTLEUNIT_ATTR ASSIGNING </BIC/CCTA0SETTLEUNIT_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0SETTLEUNIT_ATTR>-OBJNR = 1.
</BIC/CCTA0SETTLEUNIT_ATTR>-BUKRS = 1.
</BIC/CCTA0SETTLEUNIT_ATTR>-SWENR = 1.
</BIC/CCTA0SETTLEUNIT_ATTR>-SNKSL = 1.
</BIC/CCTA0SETTLEUNIT_ATTR>-SEMPSL = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0SETTLEUNIT_ATTR INTO WA_/BIC/CCTA0SETTLEUNIT_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0SETTLEUNIT_ATTR-SMIETR, sy-vline,
WA_/BIC/CCTA0SETTLEUNIT_ATTR-SUTYPE, sy-vline,
WA_/BIC/CCTA0SETTLEUNIT_ATTR-VALIDFROM, sy-vline,
WA_/BIC/CCTA0SETTLEUNIT_ATTR-DAEEND, sy-vline,
WA_/BIC/CCTA0SETTLEUNIT_ATTR-SETTLVARIANT, sy-vline,
WA_/BIC/CCTA0SETTLEUNIT_ATTR-PFROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0SETTLEUNIT_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0SETTLEUNIT_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0SETTLEUNIT_ATTR INTO WA_/BIC/CCTA0SETTLEUNIT_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0SETTLEUNIT_ATTR_STR,
OBJNR TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SNKSL TYPE STRING,
SEMPSL TYPE STRING,
SMIETR TYPE STRING,
SUTYPE TYPE STRING,
VALIDFROM TYPE STRING,
DAEEND TYPE STRING,
SETTLVARIANT TYPE STRING,
PFROM TYPE STRING,
PTO TYPE STRING,
BWSTRES1 TYPE STRING,
BWSTRES2 TYPE STRING,
BWSTREU1 TYPE STRING,
BWSTREU2 TYPE STRING,
BWSTREU3 TYPE STRING,
BWSTREU4 TYPE STRING,
BWSTREU5 TYPE STRING,
RESPONSIBLE TYPE STRING,
AUTHGRP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-OBJNR sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BUKRS sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SWENR sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SNKSL sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SEMPSL sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SMIETR sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SUTYPE sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-VALIDFROM sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-DAEEND sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-SETTLVARIANT sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-PFROM sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-PTO sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTRES1 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTRES2 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTREU1 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTREU2 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTREU3 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTREU4 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-BWSTREU5 sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-RESPONSIBLE sy-vline
WA_/BIC/CCTA0SETTLEUNIT_ATTR_STR-AUTHGRP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.