ABAP Select data from SAP table /BIC/CCTA0PM_MEASUREMENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0PM_MEASUREMENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0PM_MEASUREMENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0PM_MEASUREMENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0PM_MEASUREMENT TYPE STANDARD TABLE OF /BIC/CCTA0PM_MEASUREMENT,
      WA_/BIC/CCTA0PM_MEASUREMENT TYPE /BIC/CCTA0PM_MEASUREMENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0PM_MEASUREMENT> TYPE /BIC/CCTA0PM_MEASUREMENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0PM_MEASUREMENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0PM_MEASUREMENT
  INTO TABLE IT_/BIC/CCTA0PM_MEASUREMENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0PM_MEASUREMENT
*  INTO TABLE @DATA(IT_/BIC/CCTA0PM_MEASUREMENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0PM_MEASUREMENT INDEX 1 INTO DATA(WA_/BIC/CCTA0PM_MEASUREMENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0PM_MEASUREMENT ASSIGNING </BIC/CCTA0PM_MEASUREMENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0PM_MEASUREMENT>-POINT = 1.
</BIC/CCTA0PM_MEASUREMENT>-MDOCM = 1.
</BIC/CCTA0PM_MEASUREMENT>-MPOBJ = 1.
</BIC/CCTA0PM_MEASUREMENT>-MPTYP = 1.
</BIC/CCTA0PM_MEASUREMENT>-PSORT = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0PM_MEASUREMENT INTO WA_/BIC/CCTA0PM_MEASUREMENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0PM_MEASUREMENT-LOCAS, sy-vline,
WA_/BIC/CCTA0PM_MEASUREMENT-ATINN, sy-vline,
WA_/BIC/CCTA0PM_MEASUREMENT-IDATE, sy-vline,
WA_/BIC/CCTA0PM_MEASUREMENT-ITIME, sy-vline,
WA_/BIC/CCTA0PM_MEASUREMENT-DESIR, sy-vline,
WA_/BIC/CCTA0PM_MEASUREMENT-DESIRI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0PM_MEASUREMENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0PM_MEASUREMENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0PM_MEASUREMENT INTO WA_/BIC/CCTA0PM_MEASUREMENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0PM_MEASUREMENT_STR,
POINT TYPE STRING,
MDOCM TYPE STRING,
MPOBJ TYPE STRING,
MPTYP TYPE STRING,
PSORT TYPE STRING,
LOCAS TYPE STRING,
ATINN TYPE STRING,
IDATE TYPE STRING,
ITIME TYPE STRING,
DESIR TYPE STRING,
DESIRI TYPE STRING,
MRMIN TYPE STRING,
MRMINI TYPE STRING,
MRMAX TYPE STRING,
MRMAXI TYPE STRING,
CJUMP TYPE STRING,
PYEAR TYPE STRING,
ERNAM TYPE STRING,
READG TYPE STRING,
RECDV TYPE STRING,
RECDU TYPE STRING,
CNTRR TYPE STRING,
CDIFF TYPE STRING,
CODCT TYPE STRING,
CODGR TYPE STRING,
PREST TYPE STRING,
CANCL TYPE STRING,
MSSIE TYPE STRING,
DIMID TYPE STRING,
INDCT TYPE STRING,
VLCOD TYPE STRING,
DOCAF TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0PM_MEASUREMENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-POINT sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MDOCM sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MPOBJ sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MPTYP sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-PSORT sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-LOCAS sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-ATINN sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-IDATE sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-ITIME sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-DESIR sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-DESIRI sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MRMIN sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MRMINI sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MRMAX sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MRMAXI sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CJUMP sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-PYEAR sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-ERNAM sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-READG sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-RECDV sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-RECDU sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CNTRR sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CDIFF sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CODCT sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CODGR sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-PREST sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-CANCL sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-MSSIE sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-DIMID sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-INDCT sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-VLCOD sy-vline
WA_/BIC/CCTA0PM_MEASUREMENT_STR-DOCAF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.