ABAP Select data from SAP table /BIC/CCTA0FUNCT_LOC_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0FUNCT_LOC_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0FUNCT_LOC_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0FUNCT_LOC_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0FUNCT_LOC_ATTR TYPE STANDARD TABLE OF /BIC/CCTA0FUNCT_LOC_ATTR,
      WA_/BIC/CCTA0FUNCT_LOC_ATTR TYPE /BIC/CCTA0FUNCT_LOC_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0FUNCT_LOC_ATTR> TYPE /BIC/CCTA0FUNCT_LOC_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0FUNCT_LOC_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0FUNCT_LOC_ATTR
  INTO TABLE IT_/BIC/CCTA0FUNCT_LOC_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0FUNCT_LOC_ATTR
*  INTO TABLE @DATA(IT_/BIC/CCTA0FUNCT_LOC_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0FUNCT_LOC_ATTR INDEX 1 INTO DATA(WA_/BIC/CCTA0FUNCT_LOC_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0FUNCT_LOC_ATTR ASSIGNING </BIC/CCTA0FUNCT_LOC_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0FUNCT_LOC_ATTR>-TPLNR = 1.
</BIC/CCTA0FUNCT_LOC_ATTR>-FLTYP = 1.
</BIC/CCTA0FUNCT_LOC_ATTR>-SUBMT = 1.
</BIC/CCTA0FUNCT_LOC_ATTR>-IWERK = 1.
</BIC/CCTA0FUNCT_LOC_ATTR>-INGRP = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0FUNCT_LOC_ATTR INTO WA_/BIC/CCTA0FUNCT_LOC_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0FUNCT_LOC_ATTR-ABCKZ, sy-vline,
WA_/BIC/CCTA0FUNCT_LOC_ATTR-SWERK, sy-vline,
WA_/BIC/CCTA0FUNCT_LOC_ATTR-STORT, sy-vline,
WA_/BIC/CCTA0FUNCT_LOC_ATTR-MSGRP, sy-vline,
WA_/BIC/CCTA0FUNCT_LOC_ATTR-BEBER, sy-vline,
WA_/BIC/CCTA0FUNCT_LOC_ATTR-ADRNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0FUNCT_LOC_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0FUNCT_LOC_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0FUNCT_LOC_ATTR INTO WA_/BIC/CCTA0FUNCT_LOC_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0FUNCT_LOC_ATTR_STR,
TPLNR TYPE STRING,
FLTYP TYPE STRING,
SUBMT TYPE STRING,
IWERK TYPE STRING,
INGRP TYPE STRING,
ABCKZ TYPE STRING,
SWERK TYPE STRING,
STORT TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
ADRNR TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
BUKRS TYPE STRING,
ANLNR TYPE STRING,
DATAB TYPE STRING,
PROID TYPE STRING,
EQART TYPE STRING,
VAPLZ TYPE STRING,
VAWRK TYPE STRING,
AUFNR TYPE STRING,
ERDAT TYPE STRING,
AEDAT TYPE STRING,
ARBPL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-TPLNR sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-FLTYP sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-SUBMT sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-IWERK sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-INGRP sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-ABCKZ sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-SWERK sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-STORT sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-MSGRP sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-BEBER sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-ADRNR sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-KOKRS sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-KOSTL sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-BUKRS sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-ANLNR sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-DATAB sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-PROID sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-EQART sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-VAPLZ sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-VAWRK sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-AUFNR sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-ERDAT sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-AEDAT sy-vline
WA_/BIC/CCTA0FUNCT_LOC_ATTR_STR-ARBPL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.