ABAP Select data from SAP table /BIC/CCTA0FI_AA_12 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0FI_AA_12 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0FI_AA_12. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0FI_AA_12 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0FI_AA_12 TYPE STANDARD TABLE OF /BIC/CCTA0FI_AA_12,
      WA_/BIC/CCTA0FI_AA_12 TYPE /BIC/CCTA0FI_AA_12,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0FI_AA_12> TYPE /BIC/CCTA0FI_AA_12.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0FI_AA_12.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0FI_AA_12
  INTO TABLE IT_/BIC/CCTA0FI_AA_12.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0FI_AA_12
*  INTO TABLE @DATA(IT_/BIC/CCTA0FI_AA_122).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0FI_AA_12 INDEX 1 INTO DATA(WA_/BIC/CCTA0FI_AA_122).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0FI_AA_12 ASSIGNING </BIC/CCTA0FI_AA_12>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0FI_AA_12>-BUKRS = 1.
</BIC/CCTA0FI_AA_12>-ANLN1 = 1.
</BIC/CCTA0FI_AA_12>-ANLN2 = 1.
</BIC/CCTA0FI_AA_12>-AFABER = 1.
</BIC/CCTA0FI_AA_12>-WAERS = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0FI_AA_12 INTO WA_/BIC/CCTA0FI_AA_12.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0FI_AA_12-FISCPER, sy-vline,
WA_/BIC/CCTA0FI_AA_12-PERIV, sy-vline,
WA_/BIC/CCTA0FI_AA_12-BW_KNAFA_P, sy-vline,
WA_/BIC/CCTA0FI_AA_12-BW_KSAFA_P, sy-vline,
WA_/BIC/CCTA0FI_AA_12-BW_KAAFA_P, sy-vline,
WA_/BIC/CCTA0FI_AA_12-BW_KMAFA_P, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0FI_AA_12 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0FI_AA_12 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0FI_AA_12 INTO WA_/BIC/CCTA0FI_AA_12. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0FI_AA_12_STR,
BUKRS TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
AFABER TYPE STRING,
WAERS TYPE STRING,
FISCPER TYPE STRING,
PERIV TYPE STRING,
BW_KNAFA_P TYPE STRING,
BW_KSAFA_P TYPE STRING,
BW_KAAFA_P TYPE STRING,
BW_KMAFA_P TYPE STRING,
BW_KAUFN_P TYPE STRING,
BW_KAUFW_P TYPE STRING,
BW_KZINS_P TYPE STRING,
BW_NAFAG_P TYPE STRING,
BW_SAFAG_P TYPE STRING,
BW_AAFAG_P TYPE STRING,
BW_MAFAG_P TYPE STRING,
BW_AUFNG_P TYPE STRING,
BW_AUFWG_P TYPE STRING,
BW_ZINSG_P TYPE STRING,
KOSTL TYPE STRING,
FKBER TYPE STRING,
CAUFN TYPE STRING,
EAUFN TYPE STRING,
IAUFN TYPE STRING,
GEBER TYPE STRING,
IMKEY TYPE STRING,
FISTL TYPE STRING,
PS_PSP_PNR TYPE STRING,
SIM TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0FI_AA_12_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BUKRS sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-ANLN1 sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-ANLN2 sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-AFABER sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-WAERS sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-FISCPER sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-PERIV sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KNAFA_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KSAFA_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KAAFA_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KMAFA_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KAUFN_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KAUFW_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_KZINS_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_NAFAG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_SAFAG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_AAFAG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_MAFAG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_AUFNG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_AUFWG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-BW_ZINSG_P sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-KOSTL sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-FKBER sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-CAUFN sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-EAUFN sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-IAUFN sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-GEBER sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-IMKEY sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-FISTL sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-PS_PSP_PNR sy-vline
WA_/BIC/CCTA0FI_AA_12_STR-SIM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.