ABAP Select data from SAP table /BI0/_1CCTA_CO_PA800S00100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BI0/_1CCTA_CO_PA800S00100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BI0/_1CCTA_CO_PA800S00100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BI0/_1CCTA_CO_PA800S00100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BI0/_1CCTA_CO_PA800S00100 TYPE STANDARD TABLE OF /BI0/_1CCTA_CO_PA800S00100,
      WA_/BI0/_1CCTA_CO_PA800S00100 TYPE /BI0/_1CCTA_CO_PA800S00100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BI0/_1CCTA_CO_PA800S00100> TYPE /BI0/_1CCTA_CO_PA800S00100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BI0/_1CCTA_CO_PA800S00100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BI0/_1CCTA_CO_PA800S00100
  INTO TABLE IT_/BI0/_1CCTA_CO_PA800S00100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BI0/_1CCTA_CO_PA800S00100
*  INTO TABLE @DATA(IT_/BI0/_1CCTA_CO_PA800S001002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BI0/_1CCTA_CO_PA800S00100 INDEX 1 INTO DATA(WA_/BI0/_1CCTA_CO_PA800S001002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BI0/_1CCTA_CO_PA800S00100 ASSIGNING </BI0/_1CCTA_CO_PA800S00100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BI0/_1CCTA_CO_PA800S00100>-GJAHR = 1.
</BI0/_1CCTA_CO_PA800S00100>-PERIV = 1.
</BI0/_1CCTA_CO_PA800S00100>-PERIO = 1.
</BI0/_1CCTA_CO_PA800S00100>-WRTTP = 1.
</BI0/_1CCTA_CO_PA800S00100>-VERSI = 1.
ENDLOOP.

LOOP AT IT_/BI0/_1CCTA_CO_PA800S00100 INTO WA_/BI0/_1CCTA_CO_PA800S00100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BI0/_1CCTA_CO_PA800S00100-VRGAR, sy-vline,
WA_/BI0/_1CCTA_CO_PA800S00100-CURTYPE, sy-vline,
WA_/BI0/_1CCTA_CO_PA800S00100-VALUTYP, sy-vline,
WA_/BI0/_1CCTA_CO_PA800S00100-CALWEEK, sy-vline,
WA_/BI0/_1CCTA_CO_PA800S00100-MAABC, sy-vline,
WA_/BI0/_1CCTA_CO_PA800S00100-ARTNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BI0/_1CCTA_CO_PA800S00100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BI0/_1CCTA_CO_PA800S00100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BI0/_1CCTA_CO_PA800S00100 INTO WA_/BI0/_1CCTA_CO_PA800S00100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BI0/_1CCTA_CO_PA800S00100_STR,
GJAHR TYPE STRING,
PERIV TYPE STRING,
PERIO TYPE STRING,
WRTTP TYPE STRING,
VERSI TYPE STRING,
VRGAR TYPE STRING,
CURTYPE TYPE STRING,
VALUTYP TYPE STRING,
CALWEEK TYPE STRING,
MAABC TYPE STRING,
ARTNR TYPE STRING,
BONUS TYPE STRING,
BRSCH TYPE STRING,
BUKRS TYPE STRING,
EFORM TYPE STRING,
FKART TYPE STRING,
GEBIE TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
KNDNR TYPE STRING,
BZIRK TYPE STRING,
KDGRP TYPE STRING,
LAND1 TYPE STRING,
PRCTR TYPE STRING,
SPART TYPE STRING,
VKBUR TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
WERKS TYPE STRING,
ABSMG_ME TYPE STRING,
REC_WAERS TYPE STRING,
RKAUFNR TYPE STRING,
BELNR TYPE STRING,
BUDAT TYPE STRING,
FADAT TYPE STRING,
KSTAR TYPE STRING,
KTOPL TYPE STRING,
KSTRG TYPE STRING,
KAUFN TYPE STRING,
PSPNR TYPE STRING,
PPRCTR TYPE STRING,
KDPOS TYPE STRING,
POSNR TYPE STRING,
RBELN TYPE STRING,
RPOSN TYPE STRING,
SKOST TYPE STRING,
WADAT TYPE STRING,
STO_BELNR TYPE STRING,
STO_POSNR TYPE STRING,
ABSMG TYPE STRING,
AUSFR TYPE STRING,
ERLOS TYPE STRING,
MRABA TYPE STRING,
PRABA TYPE STRING,
PROVV TYPE STRING,
RABAT TYPE STRING,
UMSLZ TYPE STRING,
VRPRS TYPE STRING,
VSVP TYPE STRING,
VTRGK TYPE STRING,
VWGK TYPE STRING,
COPASLQTU TYPE STRING,
COPASLQTY TYPE STRING,
COPAREVEN TYPE STRING,
COPACDSCN TYPE STRING,
COPAPDSCN TYPE STRING,
COPAQDSCN TYPE STRING,
COPASPROM TYPE STRING,
COPACASHD TYPE STRING,
COPAREBAT TYPE STRING,
COPAODSCN TYPE STRING,
COPADISCT TYPE STRING,
COPANETSL TYPE STRING,
COPASCOMM TYPE STRING,
COPASDIRS TYPE STRING,
COPAFRGTC TYPE STRING,
COPADIRSL TYPE STRING,
COPANETRV TYPE STRING,
COPADMATC TYPE STRING,
COPAPRDCV TYPE STRING,
COPACOGSV TYPE STRING,
COPAMRGN1 TYPE STRING,
COPAMATOH TYPE STRING,
COPAPRDCF TYPE STRING,
COPACOGSF TYPE STRING,
COPAMRGN2 TYPE STRING,
COPAVRNCS TYPE STRING,
COPAMRGN3 TYPE STRING,
COPAOHMRK TYPE STRING,
COPAOHSLS TYPE STRING,
COPAOHADM TYPE STRING,
COPAOHRND TYPE STRING,
COPAOHLOG TYPE STRING,
COPAOHOTH TYPE STRING,
COPAOVHDC TYPE STRING,
COPAPROFT TYPE STRING,
COPAUSR01 TYPE STRING,
COPAUSR02 TYPE STRING,
COPAUSR03 TYPE STRING,
COPAUSR04 TYPE STRING,
COPAUSR05 TYPE STRING,
COPAUSR06 TYPE STRING,
COPAUSR07 TYPE STRING,
COPAUSR08 TYPE STRING,
COPAUSR09 TYPE STRING,
COPACOGS TYPE STRING,
COPACLT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BI0/_1CCTA_CO_PA800S00100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-GJAHR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PERIV sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PERIO sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-WRTTP sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VERSI sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VRGAR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-CURTYPE sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VALUTYP sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-CALWEEK sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-MAABC sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-ARTNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BONUS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BRSCH sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BUKRS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-EFORM sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-FKART sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-GEBIE sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-GSBER sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KOKRS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KNDNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BZIRK sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KDGRP sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-LAND1 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PRCTR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-SPART sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VKBUR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VKORG sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VTWEG sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-WERKS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-ABSMG_ME sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-REC_WAERS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-RKAUFNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BELNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-BUDAT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-FADAT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KSTAR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KTOPL sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KSTRG sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KAUFN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PSPNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PPRCTR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-KDPOS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-POSNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-RBELN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-RPOSN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-SKOST sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-WADAT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-STO_BELNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-STO_POSNR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-ABSMG sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-AUSFR sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-ERLOS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-MRABA sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PRABA sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-PROVV sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-RABAT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-UMSLZ sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VRPRS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VSVP sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VTRGK sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-VWGK sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPASLQTU sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPASLQTY sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAREVEN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACDSCN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAPDSCN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAQDSCN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPASPROM sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACASHD sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAREBAT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAODSCN sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPADISCT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPANETSL sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPASCOMM sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPASDIRS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAFRGTC sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPADIRSL sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPANETRV sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPADMATC sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAPRDCV sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACOGSV sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAMRGN1 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAMATOH sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAPRDCF sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACOGSF sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAMRGN2 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAVRNCS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAMRGN3 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHMRK sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHSLS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHADM sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHRND sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHLOG sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOHOTH sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAOVHDC sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAPROFT sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR01 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR02 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR03 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR04 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR05 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR06 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR07 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR08 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPAUSR09 sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACOGS sy-vline
WA_/BI0/_1CCTA_CO_PA800S00100_STR-COPACLT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.