ABAP Select data from SAP table /BEV4/PLDANFKN_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BEV4/PLDANFKN_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BEV4/PLDANFKN_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BEV4/PLDANFKN_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BEV4/PLDANFKN_S TYPE STANDARD TABLE OF /BEV4/PLDANFKN_S,
      WA_/BEV4/PLDANFKN_S TYPE /BEV4/PLDANFKN_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BEV4/PLDANFKN_S> TYPE /BEV4/PLDANFKN_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BEV4/PLDANFKN_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BEV4/PLDANFKN_S
  INTO TABLE IT_/BEV4/PLDANFKN_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BEV4/PLDANFKN_S
*  INTO TABLE @DATA(IT_/BEV4/PLDANFKN_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BEV4/PLDANFKN_S INDEX 1 INTO DATA(WA_/BEV4/PLDANFKN_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BEV4/PLDANFKN_S ASSIGNING </BEV4/PLDANFKN_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BEV4/PLDANFKN_S>-MANDT = 1.
</BEV4/PLDANFKN_S>-VKORG = 1.
</BEV4/PLDANFKN_S>-VTWEG = 1.
</BEV4/PLDANFKN_S>-SPART = 1.
</BEV4/PLDANFKN_S>-VERL = 1.
ENDLOOP.

LOOP AT IT_/BEV4/PLDANFKN_S INTO WA_/BEV4/PLDANFKN_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BEV4/PLDANFKN_S-OBJN, sy-vline,
WA_/BEV4/PLDANFKN_S-INKDN, sy-vline,
WA_/BEV4/PLDANFKN_S-MATNR, sy-vline,
WA_/BEV4/PLDANFKN_S-EXOBJ, sy-vline,
WA_/BEV4/PLDANFKN_S-EXKDN, sy-vline,
WA_/BEV4/PLDANFKN_S-MATNR_E, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BEV4/PLDANFKN_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BEV4/PLDANFKN_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BEV4/PLDANFKN_S INTO WA_/BEV4/PLDANFKN_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VERL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-VERL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-VERL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OBJN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-OBJN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-OBJN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INKDN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-INKDN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-INKDN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXOBJ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-EXOBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-EXOBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXKDN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-EXKDN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-EXKDN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-ALFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-ALFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BEV4/PLDANFKN_S-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV4/PLDANFKN_S-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BEV4/PLDANFKN_S_STR,
MANDT TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
VERL TYPE STRING,
OBJN TYPE STRING,
INKDN TYPE STRING,
MATNR TYPE STRING,
EXOBJ TYPE STRING,
EXKDN TYPE STRING,
MATNR_E TYPE STRING,
POSNR TYPE STRING,
JAHR TYPE STRING,
MONAT TYPE STRING,
TAG TYPE STRING,
MBEG TYPE STRING,
MEND TYPE STRING,
PFLAG TYPE STRING,
ALFNR TYPE STRING,
INTXT TYPE STRING,
EXTXT TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
UMNET TYPE STRING,
UMBRU TYPE STRING,
EWAERS TYPE STRING,
UFLAG TYPE STRING,
EAN11 TYPE STRING,
NUMTP TYPE STRING,
STATUS TYPE STRING,
RMLDG TYPE STRING,
RMELD TYPE STRING,
ERDAT TYPE STRING,
ERZET TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZET TYPE STRING,
AENAM TYPE STRING,
ABWADR TYPE STRING,
KEYRO TYPE STRING,
AVKORG TYPE STRING,
AUSG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BEV4/PLDANFKN_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BEV4/PLDANFKN_S_STR-MANDT sy-vline
WA_/BEV4/PLDANFKN_S_STR-VKORG sy-vline
WA_/BEV4/PLDANFKN_S_STR-VTWEG sy-vline
WA_/BEV4/PLDANFKN_S_STR-SPART sy-vline
WA_/BEV4/PLDANFKN_S_STR-VERL sy-vline
WA_/BEV4/PLDANFKN_S_STR-OBJN sy-vline
WA_/BEV4/PLDANFKN_S_STR-INKDN sy-vline
WA_/BEV4/PLDANFKN_S_STR-MATNR sy-vline
WA_/BEV4/PLDANFKN_S_STR-EXOBJ sy-vline
WA_/BEV4/PLDANFKN_S_STR-EXKDN sy-vline
WA_/BEV4/PLDANFKN_S_STR-MATNR_E sy-vline
WA_/BEV4/PLDANFKN_S_STR-POSNR sy-vline
WA_/BEV4/PLDANFKN_S_STR-JAHR sy-vline
WA_/BEV4/PLDANFKN_S_STR-MONAT sy-vline
WA_/BEV4/PLDANFKN_S_STR-TAG sy-vline
WA_/BEV4/PLDANFKN_S_STR-MBEG sy-vline
WA_/BEV4/PLDANFKN_S_STR-MEND sy-vline
WA_/BEV4/PLDANFKN_S_STR-PFLAG sy-vline
WA_/BEV4/PLDANFKN_S_STR-ALFNR sy-vline
WA_/BEV4/PLDANFKN_S_STR-INTXT sy-vline
WA_/BEV4/PLDANFKN_S_STR-EXTXT sy-vline
WA_/BEV4/PLDANFKN_S_STR-MENGE sy-vline
WA_/BEV4/PLDANFKN_S_STR-MEINS sy-vline
WA_/BEV4/PLDANFKN_S_STR-UMNET sy-vline
WA_/BEV4/PLDANFKN_S_STR-UMBRU sy-vline
WA_/BEV4/PLDANFKN_S_STR-EWAERS sy-vline
WA_/BEV4/PLDANFKN_S_STR-UFLAG sy-vline
WA_/BEV4/PLDANFKN_S_STR-EAN11 sy-vline
WA_/BEV4/PLDANFKN_S_STR-NUMTP sy-vline
WA_/BEV4/PLDANFKN_S_STR-STATUS sy-vline
WA_/BEV4/PLDANFKN_S_STR-RMLDG sy-vline
WA_/BEV4/PLDANFKN_S_STR-RMELD sy-vline
WA_/BEV4/PLDANFKN_S_STR-ERDAT sy-vline
WA_/BEV4/PLDANFKN_S_STR-ERZET sy-vline
WA_/BEV4/PLDANFKN_S_STR-ERNAM sy-vline
WA_/BEV4/PLDANFKN_S_STR-AEDAT sy-vline
WA_/BEV4/PLDANFKN_S_STR-AEZET sy-vline
WA_/BEV4/PLDANFKN_S_STR-AENAM sy-vline
WA_/BEV4/PLDANFKN_S_STR-ABWADR sy-vline
WA_/BEV4/PLDANFKN_S_STR-KEYRO sy-vline
WA_/BEV4/PLDANFKN_S_STR-AVKORG sy-vline
WA_/BEV4/PLDANFKN_S_STR-AUSG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.