ABAP Select data from SAP table /AIF/TRFC_O_UNIT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /AIF/TRFC_O_UNIT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /AIF/TRFC_O_UNIT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /AIF/TRFC_O_UNIT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/AIF/TRFC_O_UNIT TYPE STANDARD TABLE OF /AIF/TRFC_O_UNIT,
      WA_/AIF/TRFC_O_UNIT TYPE /AIF/TRFC_O_UNIT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </AIF/TRFC_O_UNIT> TYPE /AIF/TRFC_O_UNIT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/AIF/TRFC_O_UNIT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /AIF/TRFC_O_UNIT
  INTO TABLE IT_/AIF/TRFC_O_UNIT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /AIF/TRFC_O_UNIT
*  INTO TABLE @DATA(IT_/AIF/TRFC_O_UNIT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/AIF/TRFC_O_UNIT INDEX 1 INTO DATA(WA_/AIF/TRFC_O_UNIT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/AIF/TRFC_O_UNIT ASSIGNING </AIF/TRFC_O_UNIT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</AIF/TRFC_O_UNIT>-MANDT = 1.
</AIF/TRFC_O_UNIT>-UNIT_ID = 1.
</AIF/TRFC_O_UNIT>-PRED_CNT = 1.
</AIF/TRFC_O_UNIT>-REDO_CNT_AUTO = 1.
</AIF/TRFC_O_UNIT>-REDO_CNT_MANUAL = 1.
ENDLOOP.

LOOP AT IT_/AIF/TRFC_O_UNIT INTO WA_/AIF/TRFC_O_UNIT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/AIF/TRFC_O_UNIT-IS_DELETED, sy-vline,
WA_/AIF/TRFC_O_UNIT-IS_NOOP, sy-vline,
WA_/AIF/TRFC_O_UNIT-CTIMESTAMP, sy-vline,
WA_/AIF/TRFC_O_UNIT-UNAME, sy-vline,
WA_/AIF/TRFC_O_UNIT-CLIENT, sy-vline,
WA_/AIF/TRFC_O_UNIT-LANGU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/AIF/TRFC_O_UNIT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/AIF/TRFC_O_UNIT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/AIF/TRFC_O_UNIT INTO WA_/AIF/TRFC_O_UNIT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/AIF/TRFC_O_UNIT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/TRFC_O_UNIT-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/AIF/TRFC_O_UNIT_STR,
MANDT TYPE STRING,
UNIT_ID TYPE STRING,
PRED_CNT TYPE STRING,
REDO_CNT_AUTO TYPE STRING,
REDO_CNT_MANUAL TYPE STRING,
IS_DELETED TYPE STRING,
IS_NOOP TYPE STRING,
CTIMESTAMP TYPE STRING,
UNAME TYPE STRING,
CLIENT TYPE STRING,
LANGU TYPE STRING,
TCODE TYPE STRING,
CPROG TYPE STRING,
HOST_NAME TYPE STRING,
UNIT_SIZE TYPE STRING,
EXE_MODE TYPE STRING,
IS_TRACE_ON TYPE STRING,
PW_HASH TYPE STRING,
NO_COMMIT_CHECK TYPE STRING,
UNIT_HISTORY TYPE STRING,
BASXML_ENABLED TYPE STRING,
RAL_RELEVANT TYPE STRING,
PRIORITY TYPE STRING,
ADMIN_PRIV_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/AIF/TRFC_O_UNIT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/AIF/TRFC_O_UNIT_STR-MANDT sy-vline
WA_/AIF/TRFC_O_UNIT_STR-UNIT_ID sy-vline
WA_/AIF/TRFC_O_UNIT_STR-PRED_CNT sy-vline
WA_/AIF/TRFC_O_UNIT_STR-REDO_CNT_AUTO sy-vline
WA_/AIF/TRFC_O_UNIT_STR-REDO_CNT_MANUAL sy-vline
WA_/AIF/TRFC_O_UNIT_STR-IS_DELETED sy-vline
WA_/AIF/TRFC_O_UNIT_STR-IS_NOOP sy-vline
WA_/AIF/TRFC_O_UNIT_STR-CTIMESTAMP sy-vline
WA_/AIF/TRFC_O_UNIT_STR-UNAME sy-vline
WA_/AIF/TRFC_O_UNIT_STR-CLIENT sy-vline
WA_/AIF/TRFC_O_UNIT_STR-LANGU sy-vline
WA_/AIF/TRFC_O_UNIT_STR-TCODE sy-vline
WA_/AIF/TRFC_O_UNIT_STR-CPROG sy-vline
WA_/AIF/TRFC_O_UNIT_STR-HOST_NAME sy-vline
WA_/AIF/TRFC_O_UNIT_STR-UNIT_SIZE sy-vline
WA_/AIF/TRFC_O_UNIT_STR-EXE_MODE sy-vline
WA_/AIF/TRFC_O_UNIT_STR-IS_TRACE_ON sy-vline
WA_/AIF/TRFC_O_UNIT_STR-PW_HASH sy-vline
WA_/AIF/TRFC_O_UNIT_STR-NO_COMMIT_CHECK sy-vline
WA_/AIF/TRFC_O_UNIT_STR-UNIT_HISTORY sy-vline
WA_/AIF/TRFC_O_UNIT_STR-BASXML_ENABLED sy-vline
WA_/AIF/TRFC_O_UNIT_STR-RAL_RELEVANT sy-vline
WA_/AIF/TRFC_O_UNIT_STR-PRIORITY sy-vline
WA_/AIF/TRFC_O_UNIT_STR-ADMIN_PRIV_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.