ABAP Select data from SAP table /AIF/CIFPP_ADDT_INFO_ST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /AIF/CIFPP_ADDT_INFO_ST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /AIF/CIFPP_ADDT_INFO_ST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /AIF/CIFPP_ADDT_INFO_ST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/AIF/CIFPP_ADDT_INFO_ST TYPE STANDARD TABLE OF /AIF/CIFPP_ADDT_INFO_ST,
      WA_/AIF/CIFPP_ADDT_INFO_ST TYPE /AIF/CIFPP_ADDT_INFO_ST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </AIF/CIFPP_ADDT_INFO_ST> TYPE /AIF/CIFPP_ADDT_INFO_ST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/AIF/CIFPP_ADDT_INFO_ST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /AIF/CIFPP_ADDT_INFO_ST
  INTO TABLE IT_/AIF/CIFPP_ADDT_INFO_ST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /AIF/CIFPP_ADDT_INFO_ST
*  INTO TABLE @DATA(IT_/AIF/CIFPP_ADDT_INFO_ST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/AIF/CIFPP_ADDT_INFO_ST INDEX 1 INTO DATA(WA_/AIF/CIFPP_ADDT_INFO_ST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/AIF/CIFPP_ADDT_INFO_ST ASSIGNING </AIF/CIFPP_ADDT_INFO_ST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</AIF/CIFPP_ADDT_INFO_ST>-TRFCCHN = 1.
</AIF/CIFPP_ADDT_INFO_ST>-TCODE = 1.
</AIF/CIFPP_ADDT_INFO_ST>-APORL = 1.
</AIF/CIFPP_ADDT_INFO_ST>-ERRSTATUS = 1.
</AIF/CIFPP_ADDT_INFO_ST>-TID_PRED = 1.
ENDLOOP.

LOOP AT IT_/AIF/CIFPP_ADDT_INFO_ST INTO WA_/AIF/CIFPP_ADDT_INFO_ST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/AIF/CIFPP_ADDT_INFO_ST-GUID, sy-vline,
WA_/AIF/CIFPP_ADDT_INFO_ST-MATID, sy-vline,
WA_/AIF/CIFPP_ADDT_INFO_ST-LOCID, sy-vline,
WA_/AIF/CIFPP_ADDT_INFO_ST-LOCFRID, sy-vline,
WA_/AIF/CIFPP_ADDT_INFO_ST-APOTSTMP, sy-vline,
WA_/AIF/CIFPP_ADDT_INFO_ST-POSGUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/AIF/CIFPP_ADDT_INFO_ST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/AIF/CIFPP_ADDT_INFO_ST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/AIF/CIFPP_ADDT_INFO_ST INTO WA_/AIF/CIFPP_ADDT_INFO_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field APOTSTMP CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/AIF/CIFPP_ADDT_INFO_ST-APOTSTMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/CIFPP_ADDT_INFO_ST-APOTSTMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITOFMEAS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/AIF/CIFPP_ADDT_INFO_ST-UNITOFMEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/CIFPP_ADDT_INFO_ST-UNITOFMEAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYSK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/AIF/CIFPP_ADDT_INFO_ST-LOGSYSK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/CIFPP_ADDT_INFO_ST-LOGSYSK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field NOTE_LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/AIF/CIFPP_ADDT_INFO_ST-NOTE_LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/CIFPP_ADDT_INFO_ST-NOTE_LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/AIF/CIFPP_ADDT_INFO_ST_STR,
TRFCCHN TYPE STRING,
TCODE TYPE STRING,
APORL TYPE STRING,
ERRSTATUS TYPE STRING,
TID_PRED TYPE STRING,
GUID TYPE STRING,
MATID TYPE STRING,
LOCID TYPE STRING,
LOCFRID TYPE STRING,
APOTSTMP TYPE STRING,
POSGUID TYPE STRING,
SCHEDID TYPE STRING,
APPL TYPE STRING,
CONVERTNOW TYPE STRING,
MRP_AREA TYPE STRING,
STORAGELOC TYPE STRING,
ATPCAT TYPE STRING,
REVERSAL TYPE STRING,
CHECK_MODE TYPE STRING,
SPEC_STOCK TYPE STRING,
SPEC_STOCK_KEY TYPE STRING,
REQ_TSTAMP TYPE STRING,
QUANTITY TYPE STRING,
UNITOFMEAS TYPE STRING,
LOGSYSK TYPE STRING,
TRGUID TYPE STRING,
BATCH TYPE STRING,
BOPSTATUS TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
ADD_LOCNO TYPE STRING,
SPEC_STOCK_EXT TYPE STRING,
IS_INPUT TYPE STRING,
UPDTCNTR TYPE STRING,
SATDACTION TYPE STRING,
ICON_STATUS TYPE STRING,
STATUS_RESEND TYPE STRING,
BOX TYPE STRING,
HAS_NOTE TYPE STRING,
IS_DEPENDENT_LOG TYPE STRING,
HAS_DEPENDENT_LOG TYPE STRING,
IS_PREREQ_LOG TYPE STRING,
HAS_PREREQ_LOG TYPE STRING,
NOTE_LANGU TYPE STRING,
ERR_LOG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/AIF/CIFPP_ADDT_INFO_ST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-TRFCCHN sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-TCODE sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-APORL sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-ERRSTATUS sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-TID_PRED sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-GUID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-MATID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-LOCID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-LOCFRID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-APOTSTMP sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-POSGUID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-SCHEDID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-APPL sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-CONVERTNOW sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-MRP_AREA sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-STORAGELOC sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-ATPCAT sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-REVERSAL sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-CHECK_MODE sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-SPEC_STOCK sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-SPEC_STOCK_KEY sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-REQ_TSTAMP sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-QUANTITY sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-UNITOFMEAS sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-LOGSYSK sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-TRGUID sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-BATCH sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-BOPSTATUS sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-RSNUM sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-RSPOS sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-ADD_LOCNO sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-SPEC_STOCK_EXT sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-IS_INPUT sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-UPDTCNTR sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-SATDACTION sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-ICON_STATUS sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-STATUS_RESEND sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-BOX sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-HAS_NOTE sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-IS_DEPENDENT_LOG sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-HAS_DEPENDENT_LOG sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-IS_PREREQ_LOG sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-HAS_PREREQ_LOG sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-NOTE_LANGU sy-vline
WA_/AIF/CIFPP_ADDT_INFO_ST_STR-ERR_LOG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.