ABAP Select data from SAP table /ACCGO/INV_S_SCEN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ACCGO/INV_S_SCEN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ACCGO/INV_S_SCEN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /ACCGO/INV_S_SCEN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/ACCGO/INV_S_SCEN TYPE STANDARD TABLE OF /ACCGO/INV_S_SCEN, WA_/ACCGO/INV_S_SCEN TYPE /ACCGO/INV_S_SCEN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </ACCGO/INV_S_SCEN> TYPE /ACCGO/INV_S_SCEN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/ACCGO/INV_S_SCEN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /ACCGO/INV_S_SCEN INTO TABLE IT_/ACCGO/INV_S_SCEN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /ACCGO/INV_S_SCEN * INTO TABLE @DATA(IT_/ACCGO/INV_S_SCEN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/ACCGO/INV_S_SCEN INDEX 1 INTO DATA(WA_/ACCGO/INV_S_SCEN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/ACCGO/INV_S_SCEN ASSIGNING </ACCGO/INV_S_SCEN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</ACCGO/INV_S_SCEN>-ASSIGN_R_QTY_G = 1.
</ACCGO/INV_S_SCEN>-ASSIGN_QTY_T = 1.
</ACCGO/INV_S_SCEN>-ASSIGN_R_QTY_T = 1.
</ACCGO/INV_S_SCEN>-ASSIGN_QTY_A = 1.
</ACCGO/INV_S_SCEN>-ASSIGN_R_QTY_A = 1.
ENDLOOP. LOOP AT IT_/ACCGO/INV_S_SCEN INTO WA_/ACCGO/INV_S_SCEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/ACCGO/INV_S_SCEN-ASSIGN_QTY_G, sy-vline,
WA_/ACCGO/INV_S_SCEN-SCENARIO, sy-vline,
WA_/ACCGO/INV_S_SCEN-MATERIAL, sy-vline,
WA_/ACCGO/INV_S_SCEN-GR_MATERIAL, sy-vline,
WA_/ACCGO/INV_S_SCEN-APPL_DOC, sy-vline,
WA_/ACCGO/INV_S_SCEN-APPL_DOC_ITEM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ACCGO/INV_S_SCEN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ACCGO/INV_S_SCEN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ACCGO/INV_S_SCEN INTO WA_/ACCGO/INV_S_SCEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field GR_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-GR_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-GR_MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field APPL_DOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-APPL_DOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-APPL_DOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field APPL_SEQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-APPL_SEQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-APPL_SEQ_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ASSIGN_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-ASSIGN_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-ASSIGN_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-PRCTR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BASE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-BASE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-BASE_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BATCH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-BATCH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-BATCH_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field BOM_ID CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/ACCGO/INV_S_SCEN-BOM_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/INV_S_SCEN-BOM_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ACCGO/INV_S_SCEN_STR,
ASSIGN_R_QTY_G TYPE STRING,
ASSIGN_QTY_T TYPE STRING,
ASSIGN_R_QTY_T TYPE STRING,
ASSIGN_QTY_A TYPE STRING,
ASSIGN_R_QTY_A TYPE STRING,
ASSIGN_QTY_G TYPE STRING,
SCENARIO TYPE STRING,
MATERIAL TYPE STRING,
GR_MATERIAL TYPE STRING,
APPL_DOC TYPE STRING,
APPL_DOC_ITEM TYPE STRING,
APPL_SIDE TYPE STRING,
APPL_SEQ_NO TYPE STRING,
GM_EVENT_IND TYPE STRING,
APPL_GUID TYPE STRING,
APPL_VERSION TYPE STRING,
ASSIGN_UOM TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CSL_LGORT TYPE STRING,
PRCTR TYPE STRING,
INTRANSIT_FLAG TYPE STRING,
IS_OWNER TYPE STRING,
IC_SCENARIO TYPE STRING,
COMM_FLAG TYPE STRING,
QTY_G TYPE STRING,
R_QTY_G TYPE STRING,
QTY_T TYPE STRING,
R_QTY_T TYPE STRING,
QTY_A TYPE STRING,
R_QTY_A TYPE STRING,
BASE_UOM TYPE STRING,
BATCH_QTY_G TYPE STRING,
BATCH_R_QTY_G TYPE STRING,
BATCH_QTY_T TYPE STRING,
BATCH_R_QTY_T TYPE STRING,
BATCH_QTY_A TYPE STRING,
BATCH_R_QTY_A TYPE STRING,
BATCH_UOM TYPE STRING,
BOM_ID TYPE STRING,
BOM_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ACCGO/INV_S_SCEN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_R_QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_R_QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_R_QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-SCENARIO sy-vline
WA_/ACCGO/INV_S_SCEN_STR-MATERIAL sy-vline
WA_/ACCGO/INV_S_SCEN_STR-GR_MATERIAL sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_DOC sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_DOC_ITEM sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_SIDE sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_SEQ_NO sy-vline
WA_/ACCGO/INV_S_SCEN_STR-GM_EVENT_IND sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_GUID sy-vline
WA_/ACCGO/INV_S_SCEN_STR-APPL_VERSION sy-vline
WA_/ACCGO/INV_S_SCEN_STR-ASSIGN_UOM sy-vline
WA_/ACCGO/INV_S_SCEN_STR-WERKS sy-vline
WA_/ACCGO/INV_S_SCEN_STR-LGORT sy-vline
WA_/ACCGO/INV_S_SCEN_STR-CSL_LGORT sy-vline
WA_/ACCGO/INV_S_SCEN_STR-PRCTR sy-vline
WA_/ACCGO/INV_S_SCEN_STR-INTRANSIT_FLAG sy-vline
WA_/ACCGO/INV_S_SCEN_STR-IS_OWNER sy-vline
WA_/ACCGO/INV_S_SCEN_STR-IC_SCENARIO sy-vline
WA_/ACCGO/INV_S_SCEN_STR-COMM_FLAG sy-vline
WA_/ACCGO/INV_S_SCEN_STR-QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-R_QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-R_QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-R_QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BASE_UOM sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_R_QTY_G sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_R_QTY_T sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_R_QTY_A sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BATCH_UOM sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BOM_ID sy-vline
WA_/ACCGO/INV_S_SCEN_STR-BOM_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.