ABAP Select data from SAP table /WSOPT/C_ASSIGNMENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /WSOPT/C_ASSIGNMENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /WSOPT/C_ASSIGNMENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /WSOPT/C_ASSIGNMENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/WSOPT/C_ASSIGNMENT TYPE STANDARD TABLE OF /WSOPT/C_ASSIGNMENT,
      WA_/WSOPT/C_ASSIGNMENT TYPE /WSOPT/C_ASSIGNMENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </WSOPT/C_ASSIGNMENT> TYPE /WSOPT/C_ASSIGNMENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/WSOPT/C_ASSIGNMENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /WSOPT/C_ASSIGNMENT
  INTO TABLE IT_/WSOPT/C_ASSIGNMENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /WSOPT/C_ASSIGNMENT
*  INTO TABLE @DATA(IT_/WSOPT/C_ASSIGNMENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/WSOPT/C_ASSIGNMENT INDEX 1 INTO DATA(WA_/WSOPT/C_ASSIGNMENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/WSOPT/C_ASSIGNMENT ASSIGNING </WSOPT/C_ASSIGNMENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</WSOPT/C_ASSIGNMENT>-SAPID = 1.
</WSOPT/C_ASSIGNMENT>-ORDERID = 1.
</WSOPT/C_ASSIGNMENT>-OPERATION = 1.
</WSOPT/C_ASSIGNMENT>-SUB_OPERATION = 1.
</WSOPT/C_ASSIGNMENT>-ASSIGNMENT_KEY = 1.
ENDLOOP.

LOOP AT IT_/WSOPT/C_ASSIGNMENT INTO WA_/WSOPT/C_ASSIGNMENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/WSOPT/C_ASSIGNMENT-CALLID, sy-vline,
WA_/WSOPT/C_ASSIGNMENT-NUM, sy-vline,
WA_/WSOPT/C_ASSIGNMENT-ASS_START, sy-vline,
WA_/WSOPT/C_ASSIGNMENT-ASS_END, sy-vline,
WA_/WSOPT/C_ASSIGNMENT-ENGINEERS, sy-vline,
WA_/WSOPT/C_ASSIGNMENT-COMMENTS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/WSOPT/C_ASSIGNMENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/WSOPT/C_ASSIGNMENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/WSOPT/C_ASSIGNMENT INTO WA_/WSOPT/C_ASSIGNMENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ORDERID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/WSOPT/C_ASSIGNMENT-ORDERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/WSOPT/C_ASSIGNMENT-ORDERID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field OPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/WSOPT/C_ASSIGNMENT-OPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/WSOPT/C_ASSIGNMENT-OPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field SUB_OPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/WSOPT/C_ASSIGNMENT-SUB_OPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/WSOPT/C_ASSIGNMENT-SUB_OPERATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/WSOPT/C_ASSIGNMENT_STR,
SAPID TYPE STRING,
ORDERID TYPE STRING,
OPERATION TYPE STRING,
SUB_OPERATION TYPE STRING,
ASSIGNMENT_KEY TYPE STRING,
CALLID TYPE STRING,
NUM TYPE STRING,
ASS_START TYPE STRING,
ASS_END TYPE STRING,
ENGINEERS TYPE STRING,
COMMENTS TYPE STRING,
LOCATION TYPE STRING,
STATUS TYPE STRING,
UPDATE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/WSOPT/C_ASSIGNMENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-SAPID sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-ORDERID sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-OPERATION sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-SUB_OPERATION sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-ASSIGNMENT_KEY sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-CALLID sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-NUM sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-ASS_START sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-ASS_END sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-ENGINEERS sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-COMMENTS sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-LOCATION sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-STATUS sy-vline
WA_/WSOPT/C_ASSIGNMENT_STR-UPDATE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.