ABAP Select data from SAP table /SEHS/DGS_1078DGDATA0 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SEHS/DGS_1078DGDATA0 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SEHS/DGS_1078DGDATA0. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SEHS/DGS_1078DGDATA0 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SEHS/DGS_1078DGDATA0 TYPE STANDARD TABLE OF /SEHS/DGS_1078DGDATA0,
      WA_/SEHS/DGS_1078DGDATA0 TYPE /SEHS/DGS_1078DGDATA0,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SEHS/DGS_1078DGDATA0> TYPE /SEHS/DGS_1078DGDATA0.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SEHS/DGS_1078DGDATA0.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SEHS/DGS_1078DGDATA0
  INTO TABLE IT_/SEHS/DGS_1078DGDATA0.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SEHS/DGS_1078DGDATA0
*  INTO TABLE @DATA(IT_/SEHS/DGS_1078DGDATA02).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SEHS/DGS_1078DGDATA0 INDEX 1 INTO DATA(WA_/SEHS/DGS_1078DGDATA02).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SEHS/DGS_1078DGDATA0 ASSIGNING </SEHS/DGS_1078DGDATA0>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SEHS/DGS_1078DGDATA0>-RECORD_NO = 1.
</SEHS/DGS_1078DGDATA0>-CHNGSTATUS = 1.
</SEHS/DGS_1078DGDATA0>-VALID_FROM = 1.
</SEHS/DGS_1078DGDATA0>-VALID_TO = 1.
</SEHS/DGS_1078DGDATA0>-CHANGE_NO = 1.
ENDLOOP.

LOOP AT IT_/SEHS/DGS_1078DGDATA0 INTO WA_/SEHS/DGS_1078DGDATA0.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SEHS/DGS_1078DGDATA0-DELIND, sy-vline,
WA_/SEHS/DGS_1078DGDATA0-PARK_IND, sy-vline,
WA_/SEHS/DGS_1078DGDATA0-CREATED_ON, sy-vline,
WA_/SEHS/DGS_1078DGDATA0-CREATED_BY, sy-vline,
WA_/SEHS/DGS_1078DGDATA0-CHANGED_ON, sy-vline,
WA_/SEHS/DGS_1078DGDATA0-CHANGED_BY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SEHS/DGS_1078DGDATA0 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SEHS/DGS_1078DGDATA0 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SEHS/DGS_1078DGDATA0 INTO WA_/SEHS/DGS_1078DGDATA0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SEHS/DGS_1078DGDATA0_STR,
RECORD_NO TYPE STRING,
CHNGSTATUS TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
CHANGE_NO TYPE STRING,
DELIND TYPE STRING,
PARK_IND TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
SOURCESYS TYPE STRING,
REC_NO_ROOT TYPE STRING,
MATERIAL TYPE STRING,
MODTRANCAT TYPE STRING,
VAL_AREA TYPE STRING,
NO_DANGGOOD TYPE STRING,
ONLY_CARGO TYPE STRING,
CATEGORY TYPE STRING,
UN_NO TYPE STRING,
HAZIND_1 TYPE STRING,
HAZIND_2 TYPE STRING,
CLASS TYPE STRING,
SUB_CLASS TYPE STRING,
DANGGOOD_NUM TYPE STRING,
NO_EMTTRAN TYPE STRING,
LETTER TYPE STRING,
REGULATION TYPE STRING,
AGGRTTRANS TYPE STRING,
CTRL_TEMP TYPE STRING,
CT_UNIT TYPE STRING,
CT_UNIT_ISO TYPE STRING,
EM_TEMP TYPE STRING,
EM_UNIT TYPE STRING,
EM_UNIT_ISO TYPE STRING,
FLASH_PT TYPE STRING,
FP_UNIT TYPE STRING,
FP_UNIT_ISO TYPE STRING,
MINTEMPSEN TYPE STRING,
MI_UNIT TYPE STRING,
MI_UNIT_ISO TYPE STRING,
MAXTEMPSEN TYPE STRING,
MA_UNIT TYPE STRING,
MA_UNIT_ISO TYPE STRING,
HAZ_NOTE_1 TYPE STRING,
HAZ_NOTE_2 TYPE STRING,
HAZ_NOTE_3 TYPE STRING,
HAZ_NOTE_4 TYPE STRING,
HAZ_NOTE_5 TYPE STRING,
HAZ_NOTE_6 TYPE STRING,
HAZ_NOTE_7 TYPE STRING,
HAZ_NOTE_8 TYPE STRING,
HAZ_NOTE_9 TYPE STRING,
HAZNOTE_10 TYPE STRING,
WAPOLLCLA TYPE STRING,
VBFCLA TYPE STRING,
STHAZCLS TYPE STRING,
TREM_NO_1 TYPE STRING,
TREM_NO_2 TYPE STRING,
EMS_NO_1 TYPE STRING,
EMS_NO_2 TYPE STRING,
MFAG_NO_1 TYPE STRING,
MFAG_NO_2 TYPE STRING,
TRANSCAT_1 TYPE STRING,
TRANSCAT_2 TYPE STRING,
TRANSCAT_3 TYPE STRING,
TRANSCAT_4 TYPE STRING,
TRANSCAT_5 TYPE STRING,
TRANSCAT_6 TYPE STRING,
TRANSCAT_7 TYPE STRING,
TRANSCAT_8 TYPE STRING,
TRANSCAT_9 TYPE STRING,
TRANSCAT_10 TYPE STRING,
MAXQUTRUN TYPE STRING,
MQ_UNIT TYPE STRING,
MQ_UNIT_ISO TYPE STRING,
PIN TYPE STRING,
PCKGGRP TYPE STRING,
HAZID_NO TYPE STRING,
DANLAB_1 TYPE STRING,
DANLAB_2 TYPE STRING,
DANLAB_3 TYPE STRING,
DANLAB_4 TYPE STRING,
DANLAB_5 TYPE STRING,
DANLAB_6 TYPE STRING,
DANLAB_7 TYPE STRING,
LABNO_1 TYPE STRING,
LABNO_2 TYPE STRING,
LABNO_3 TYPE STRING,
LABNO_4 TYPE STRING,
LABNO_5 TYPE STRING,
LABNO_6 TYPE STRING,
LABNO_7 TYPE STRING,
LABNO_8 TYPE STRING,
LABNO_9 TYPE STRING,
LABNO_10 TYPE STRING,
HIVISCSUBS TYPE STRING,
EXEMPTION TYPE STRING,
MARPOLL TYPE STRING,
EXCEP_NO TYPE STRING,
HANDLDATA TYPE STRING,
PROP_SHIP_NAME TYPE STRING,
HAZIND_PHR_1 TYPE STRING,
HAZIND_PHR_2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SEHS/DGS_1078DGDATA0_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-RECORD_NO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CHNGSTATUS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-VALID_FROM sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-VALID_TO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CHANGE_NO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DELIND sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-PARK_IND sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CREATED_ON sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CREATED_BY sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CHANGED_ON sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CHANGED_BY sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-SOURCESYS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-REC_NO_ROOT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MATERIAL sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MODTRANCAT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-VAL_AREA sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-NO_DANGGOOD sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-ONLY_CARGO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CATEGORY sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-UN_NO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZIND_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZIND_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CLASS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-SUB_CLASS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANGGOOD_NUM sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-NO_EMTTRAN sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LETTER sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-REGULATION sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-AGGRTTRANS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CTRL_TEMP sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CT_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-CT_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EM_TEMP sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EM_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EM_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-FLASH_PT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-FP_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-FP_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MINTEMPSEN sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MI_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MI_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MAXTEMPSEN sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MA_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MA_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_3 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_4 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_5 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_6 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_7 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_8 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZ_NOTE_9 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZNOTE_10 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-WAPOLLCLA sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-VBFCLA sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-STHAZCLS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TREM_NO_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TREM_NO_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EMS_NO_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EMS_NO_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MFAG_NO_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MFAG_NO_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_3 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_4 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_5 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_6 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_7 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_8 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_9 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-TRANSCAT_10 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MAXQUTRUN sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MQ_UNIT sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MQ_UNIT_ISO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-PIN sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-PCKGGRP sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZID_NO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_3 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_4 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_5 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_6 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-DANLAB_7 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_2 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_3 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_4 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_5 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_6 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_7 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_8 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_9 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-LABNO_10 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HIVISCSUBS sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EXEMPTION sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-MARPOLL sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-EXCEP_NO sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HANDLDATA sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-PROP_SHIP_NAME sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZIND_PHR_1 sy-vline
WA_/SEHS/DGS_1078DGDATA0_STR-HAZIND_PHR_2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.