ABAP Select data from SAP table /SCWM/WMR_LINK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/WMR_LINK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/WMR_LINK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/WMR_LINK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/WMR_LINK TYPE STANDARD TABLE OF /SCWM/WMR_LINK,
      WA_/SCWM/WMR_LINK TYPE /SCWM/WMR_LINK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/WMR_LINK> TYPE /SCWM/WMR_LINK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/WMR_LINK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/WMR_LINK
  INTO TABLE IT_/SCWM/WMR_LINK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/WMR_LINK
*  INTO TABLE @DATA(IT_/SCWM/WMR_LINK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/WMR_LINK INDEX 1 INTO DATA(WA_/SCWM/WMR_LINK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/WMR_LINK ASSIGNING </SCWM/WMR_LINK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/WMR_LINK>-CLIENT = 1.
</SCWM/WMR_LINK>-BRELGUID = 1.
</SCWM/WMR_LINK>-RELTYPE = 1.
</SCWM/WMR_LINK>-INSTID_A = 1.
</SCWM/WMR_LINK>-TYPEID_A = 1.
ENDLOOP.

LOOP AT IT_/SCWM/WMR_LINK INTO WA_/SCWM/WMR_LINK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/WMR_LINK-CATID_A, sy-vline,
WA_/SCWM/WMR_LINK-INSTID_B, sy-vline,
WA_/SCWM/WMR_LINK-TYPEID_B, sy-vline,
WA_/SCWM/WMR_LINK-CATID_B, sy-vline,
WA_/SCWM/WMR_LINK-LOGSYS_A, sy-vline,
WA_/SCWM/WMR_LINK-ARCH_A, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/WMR_LINK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/WMR_LINK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/WMR_LINK INTO WA_/SCWM/WMR_LINK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS_A CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/WMR_LINK-LOGSYS_A IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/WMR_LINK-LOGSYS_A.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS_B CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/WMR_LINK-LOGSYS_B IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/WMR_LINK-LOGSYS_B.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HOMESYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/WMR_LINK-HOMESYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/WMR_LINK-HOMESYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/WMR_LINK_STR,
CLIENT TYPE STRING,
BRELGUID TYPE STRING,
RELTYPE TYPE STRING,
INSTID_A TYPE STRING,
TYPEID_A TYPE STRING,
CATID_A TYPE STRING,
INSTID_B TYPE STRING,
TYPEID_B TYPE STRING,
CATID_B TYPE STRING,
LOGSYS_A TYPE STRING,
ARCH_A TYPE STRING,
LOGSYS_B TYPE STRING,
ARCH_B TYPE STRING,
UTCTIME TYPE STRING,
HOMESYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/WMR_LINK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/WMR_LINK_STR-CLIENT sy-vline
WA_/SCWM/WMR_LINK_STR-BRELGUID sy-vline
WA_/SCWM/WMR_LINK_STR-RELTYPE sy-vline
WA_/SCWM/WMR_LINK_STR-INSTID_A sy-vline
WA_/SCWM/WMR_LINK_STR-TYPEID_A sy-vline
WA_/SCWM/WMR_LINK_STR-CATID_A sy-vline
WA_/SCWM/WMR_LINK_STR-INSTID_B sy-vline
WA_/SCWM/WMR_LINK_STR-TYPEID_B sy-vline
WA_/SCWM/WMR_LINK_STR-CATID_B sy-vline
WA_/SCWM/WMR_LINK_STR-LOGSYS_A sy-vline
WA_/SCWM/WMR_LINK_STR-ARCH_A sy-vline
WA_/SCWM/WMR_LINK_STR-LOGSYS_B sy-vline
WA_/SCWM/WMR_LINK_STR-ARCH_B sy-vline
WA_/SCWM/WMR_LINK_STR-UTCTIME sy-vline
WA_/SCWM/WMR_LINK_STR-HOMESYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.