ABAP Select data from SAP table /SCWM/VDTYPE_E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/VDTYPE_E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/VDTYPE_E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/VDTYPE_E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/VDTYPE_E TYPE STANDARD TABLE OF /SCWM/VDTYPE_E,
      WA_/SCWM/VDTYPE_E TYPE /SCWM/VDTYPE_E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/VDTYPE_E> TYPE /SCWM/VDTYPE_E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/VDTYPE_E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/VDTYPE_E
  INTO TABLE IT_/SCWM/VDTYPE_E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/VDTYPE_E
*  INTO TABLE @DATA(IT_/SCWM/VDTYPE_E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/VDTYPE_E INDEX 1 INTO DATA(WA_/SCWM/VDTYPE_E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/VDTYPE_E ASSIGNING </SCWM/VDTYPE_E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/VDTYPE_E>-MANDT = 1.
</SCWM/VDTYPE_E>-TYPE = 1.
</SCWM/VDTYPE_E>-CATEGORY = 1.
</SCWM/VDTYPE_E>-PROCESSCAT = 1.
</SCWM/VDTYPE_E>-NUMRIN = 1.
ENDLOOP.

LOOP AT IT_/SCWM/VDTYPE_E INTO WA_/SCWM/VDTYPE_E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/VDTYPE_E-CHANGE_DOC, sy-vline,
WA_/SCWM/VDTYPE_E-RES_TIME, sy-vline,
WA_/SCWM/VDTYPE_E-ACTION_PROF, sy-vline,
WA_/SCWM/VDTYPE_E-STATUS_PROF, sy-vline,
WA_/SCWM/VDTYPE_E-TEXT_PROF, sy-vline,
WA_/SCWM/VDTYPE_E-FLDCTR_PROF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/VDTYPE_E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/VDTYPE_E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/VDTYPE_E INTO WA_/SCWM/VDTYPE_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/VDTYPE_E_STR,
MANDT TYPE STRING,
TYPE TYPE STRING,
CATEGORY TYPE STRING,
PROCESSCAT TYPE STRING,
NUMRIN TYPE STRING,
CHANGE_DOC TYPE STRING,
RES_TIME TYPE STRING,
ACTION_PROF TYPE STRING,
STATUS_PROF TYPE STRING,
TEXT_PROF TYPE STRING,
FLDCTR_PROF TYPE STRING,
PARTNER_PROF TYPE STRING,
DATE_PROF TYPE STRING,
ICC_PROF TYPE STRING,
QUOOFF_PROF TYPE STRING,
REF_PROF TYPE STRING,
PROC_PROF TYPE STRING,
DESCRIPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/VDTYPE_E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/VDTYPE_E_STR-MANDT sy-vline
WA_/SCWM/VDTYPE_E_STR-TYPE sy-vline
WA_/SCWM/VDTYPE_E_STR-CATEGORY sy-vline
WA_/SCWM/VDTYPE_E_STR-PROCESSCAT sy-vline
WA_/SCWM/VDTYPE_E_STR-NUMRIN sy-vline
WA_/SCWM/VDTYPE_E_STR-CHANGE_DOC sy-vline
WA_/SCWM/VDTYPE_E_STR-RES_TIME sy-vline
WA_/SCWM/VDTYPE_E_STR-ACTION_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-STATUS_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-TEXT_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-FLDCTR_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-PARTNER_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-DATE_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-ICC_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-QUOOFF_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-REF_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-PROC_PROF sy-vline
WA_/SCWM/VDTYPE_E_STR-DESCRIPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.